Lightolier CDS2GPF2FT User Manual

Mounting Methods Dimensions
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
10/07
Coffaire Drop Basket Recessed Fluorescent CDS2GPF2FT
Static, 2 Lamp Twin Tube T5
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company Section 5/Folio M15-88
exposed slot t-grid ceiling
Acoustical material by others
1-7/8"
max.
Exposed T-bar by others
9/16"
24"
Features
• Direct/indirect lamp shield appearance with soft contoured interior.
• Perforated mesh lamp shield with white acrylic overlay.
• 55.0% efficient (2 lamp TT5).
• Only 2-1/4" plenum depth.
Same fixture fits both G and T ceiling types.
• Fits flush to face of slot grid (T) ceiling.
• Lamp shield hinges from either side.
• Wiring access plate standard.
• Optional DALI ballast iGEN TECHNOLOGY accepts digital dimming controllers, scene controllers and automatic control devices.
• Construction to meet Chicago Plenum available.
• Meets NYC Code requirements.
• Not for continuous row mounting.
Features
The fixture affixes to the outside of a ceiling's t bar and will not detach acting like an earthquake clip
Lamp shield hinges either side
T-bar by others
T-bar by others
exposed t-grid ceiling
Exposed T-bar by others
1-1/2" max.
Acoustical material by others
15/16" *
24"
* For flush mounting when using 9/16" Exposed T-Grid
ceiling system consult factory
Coffaire Drop Basket Recessed Fluorescent CDS2GPF2FT
Static, 2 Lamp Twin Tube T5
Job Information Type:
Ordering Information
Explanation of Catalog Number. Example: CDS2GPF2FTUNVPR
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 40W luminaire in a room cavity ratio
of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .56. To reduce glare the average brightness at 65° shall not exceed 3473 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 75.8%.
Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic
overlay.
Finish: Chassis exterior – soft white post painted polyester powder. Cavity – soft white post painted polyester powder. Reflector – soft white post painted polyester powder, minimum 88% reflectance. Rust preventive undercoating.
Lamp Shield – soft white post painted polyester powder. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
CD
Options:
Add appropriate suffix to catalog
no., ie: (GLR)
Coffaire Drop
Basket
Direct/Indirect
Recessed
S
Body Style:
S = Static
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
P
Perforated
Lamp
Shield
FT
Lamp:
(By Others)
FT=Twin Tube T5
(Nominal 24")
F
Flat White
Reflector
Lamp
Quantity 2=2 Lamp
Ballast Type:
<20THD <10THD
1 or 2 Lamp Elec. TT5 SB* IB*
*
(40 Watt)
1 or 2 Lamp Elec. TT5 PR†
(40 Watt)
LOL Dimming TT5 PB *Instant Start Standard. Other dimming options. Consult factory.
NOTE:
For TT5 40W UNV, you must use PR Ballast Code. †Program Rapid Start
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company Section 5/Folio M15-88
Voltage:
120, 277 or
UNV=120-277
CD
Standard Coffaire Drop Basket
YD
For NYC Code – Local 3 Manufactured
0.0 45.0 90.0 FLUX
0 1088 1088 1088
5 1078 1081 1084 103
15 1020 1038 1053 293
25 921 960 999 443
35 788 857 926 537
45 625 739 837 568
55 446 612 735 538
65 273 486 621 462
75 141 359 474 350
85 32 172 252 173
90 4 58 111
Model No. CDS2GPF2FTUNVPR
LER = FP - 45.0 IW - 69.3 BF - 0.90 Comparative yearly lighting energy cost per
1000 lumens = $5.34
Report Number: G2007138 Catalog Number: CDS2GPF2FTUNVPR Lamps: (2) F40 TT5 Luminaire: Coffaire Drop Basket Ballast: C240PUNVHP-B Report is based on 3150 Lumens per lamp.
Efficiency: 55.0% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 23.040 23.040
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2623. 2750. 3114. 55 1963. 2694. 3235. 65 1527. 2719. 3474. 75 1129. 2875. 3796. 85 476. 2560. 3751.
LUMINANCE DATA IN CANDELA/SQ. METER
ZONE LUMENS % LAMP % FIXT
00-030 839 13.3 24.2 00-040 1376 21.8 39.7 00-060 2482 39.4 71.6 00-090 3468 55.0 100.0
90-180
00000.0000.0
00-180 3468 55.0 100.0
ZONAL LUMEN SUMMARY
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01595653525048504847 02534844454239434038 03484237393532383431 04443732353027333027 05403328312723302623 06372924282420272320 07342722252118242118 08322419231916221916 09302218211714211714
10 28 21 16 20 16 13 19 15 13
Loading...