Lightolier Calculite C7E17VW Specification

Calculite
®
HID Downlight C7E17VW
Page 1 of 2 7" Aperture, ED17 (Enclosed), Ceramic Metal Halide, Wide Beam
Job Information Type:
Job Name: Cat. No.:
Lamp(s): Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4
Ceiling Cutout: 8" (203 mm) Dia.
Reflector Trim Frame-In Kit Lamp (Coated, Ceramic MH)
C7E17VW CLW Specular Clear,White Painted Flange.
CLP Specular Clear,Matching Flange. CCDW Comfort Clear Diffuse, White Painted Flange. CCDP Comfort Clear Diffuse, Matching Flange. CCZW Champagne Bronze, White Painted Flange. CCZP Champagne Bronze, Matching Flange.
C770MHE1 Electronic 120V 70W ED17, BD17 (Enclosed) C770MHE2 Electronic 277V 70W ED17, BD17 (Enclosed) C710MHE1 Electronic 120V 100W ED17, BD17 (Enclosed) C710MHE2 Electronic 277V 100W ED17, BD17 (Enclosed) C770MHU Magnetic 120V/277V 70W ED17, BD17 (Enclosed) C710MHU Magnetic 120V/277V 100W ED17, BD17 (Enclosed)
Features
1. Upper Reflector: Clear anodized aluminum, 0.040” (16-ga.). Provides wide
beam distribution.
2. Aperture Cone: Provides 50°visual cut-off to lamp and lamp image; self-flange in painted white or aperture-matching polished flange. Consult factory for other finishes.
3. Lamp Guard: High heat resistant glass as required by code.
4. Socket Housing: Galvanized steel, snaps onto upper reflector for secure
attachment without tools; assures proper lamp alignment to optics for consistent performance.
5. Mounting Frame: 0.048" (18-ga.) galvanized steel includes pre-installed mounting bars.
6. Mounting Ring: 0.048" (18-ga.) galvanized steel. Designed for vertical adjustment from above or below for ceilings from 0" to 2" thick. Center-line notches allow consistent alignment of multiple fixtures.
7. Retention Springs: Rust resistant springs secure cone in place for quick, tool-less installation.
8. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation.
9. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attach­ment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories.
10.Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V). Accessible from below for inspection and/or replacement without tools.
11.Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors; allows inspection from below.
12.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high-power factor, T.H.D.
<15%, thermally and transient protected, RMI / RFI complies with FCC Part 18 non-consumer equipment, shut-down circuit at end of lamp life, sound rating "A",
-5°F minimum starting temperature, Type 1 outdoor rating.
Electrical (cont)
Ballast ANSI Code Voltage Max. Amps Input Watts
70W MH M98/M143 120/277 0.67/0.28 78
100W MH M90/M140 120/277 0.90/0.43 110 Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, HX-HPF circuit type, high power factor, sound rating “B”, -20°F minimum starting temperature, Type 1 Outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts
70W MH M98/M143 120/277 1.90/0.80 94
100W MH M90/M140 120/277 2.40/1.10 125
Options and Accessories
Auxiliary: Add suffix Ato Frame-In Kit and Reflector Trim. See Spec.Sheet ”A“. Emergency Lamp: Add suffix Eto Reflector Trim and Frame In Kit. See
Spec.Sheet “E”.
Slope Ceiling Adapters: See Specification Sheet SCA. Fuse (magnetic ballast): Add suffix F1 or F2 to Frame In Kit (F1=120V, F2=277V) Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Damp Locations), CSA (magnetic ballast only), I.B.E.W. For 100W electronic, install fixtures with minimum spacing: 2 feet from center-to-center of adjacent luminaries; 1/2 inch from top of luminaire to over­head building member; 1 foot from luminaire center to side building member.
Calculite
®
HID Downlight C7E17VW
Page 2 of 2 7" Aperture, ED17 (Enclosed), Ceramic Metal halide, Wide Beam
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4
Job Information Type:
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .74 .74 .74 .74 .72 .72 .69 .69 .66 .66 .62 1 .71 .69 .68 .66 .68 .65 .65 .63 .63 .61 .58 2 .67 .65 .63 .61 .64 .60 .62 .59 .60 .57 .55 3 .64 .61 .58 .56 .60 .55 .58 .55 .57 .54 .52 4 .61 .57 .54 .52 .57 .51 .55 .51 .54 .50 .49 5 .59 .54 .50 .48 .53 .48 .52 .47 .51 .47 .46 6 .56 .51 .47 .45 .50 .45 .49 .44 .48 .44 .43 7 .53 .47 .44 .42 .47 .41 .46 .41 .45 .41 .40 8 .50 .44 .41 .38 .44 .38 .43 .38 .43 .38 .37 9 .47 .42 .38 .35 .41 .35 .41 .35 .40 .35 .34 10 .45 .39 .35 .33 .39 .33 .38 .33 .38 .33 .32
LUMINAIRE INPUT WATTS = 78.0
ANGLE MEAN CP LUMENS
0 3077
5 3138 298 10 3124 15 3095 861 20 2830 25 2407 1111 30 1960 35 1523 949 40 1036 45 609 461 50 130 55 7 33 60 1 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
70W ED17 (ENCLOSED) PHILIPS CMH, LUMEN RATING = 6000 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM
Coefficients of Utilization
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 34796 55 475 65 0 75 0 85 0
** EFFICIENCY = 61.9% ** CERTIFIED TEST REPORT NO. 2412FR, DATE: JAN 12, 2004 SC = 1.0 COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 2269 37.83 61.13 0-40 3218 53.64 86.69 0-60 3712 61.87 99.99
0-90 3712 61.88 100 40-90 494 8.24 13.31 60-90 0 0 0.01
90-180 0 0 0
0-180 3712 61.88 100
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
30°
60°
1,500
750
2,250
3,000
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .74 .74 .74 .74 .72 .72 .69 .69 .66 .66 .62 1 .70 .69 .67 .66 .68 .65 .65 .63 .63 .61 .58 2 .67 .65 .63 .61 .64 .60 .62 .59 .60 .57 .55 3 .64 .61 .58 .56 .60 .55 .58 .54 .57 .54 .52 4 .61 .57 .54 .52 .57 .51 .55 .51 .54 .50 .49 5 .58 .54 .50 .48 .53 .48 .52 .47 .51 .47 .46 6 .56 .51 .47 .45 .50 .45 .49 .44 .48 .44 .43 7 .53 .47 .44 .42 .47 .41 .46 .41 .45 .41 .40 8 .50 .44 .41 .38 .44 .38 .43 .38 .43 .38 .37 9 .47 .42 .38 .35 .41 .35 .41 .35 .40 .35 .34 10 .45 .39 .35 .33 .39 .33 .38 .33 .38 .33 .32
LUMINAIRE INPUT WATTS = 110.0
ANGLE MEAN CP LUMENS
0 4614
5 4705 446 10 4685 15 4641 1291 20 4244 25 3609 1667 30 2940 35 2283 1423 40 1553 45 912 691 50 195 55 9 48 60 1 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
100W ED17 (ENCLOSED) PHILIPS CMH, LUMEN RATING = 9000 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM
Coefficients of Utilization
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 52135 55 639 65 0 75 0 85 0
** EFFICIENCY = 61.8% ** CERTIFIED TEST REPORT NO. 2509FR , DATE: MAR 3, 2004
SC = 1.0 COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 3403 37.82 61.15 0-40 4826 53.62 86.71 0-60 5565 61.84 100
0-90 5565 61.84 100 40-90 739 8.22 13.29 60-90 0 0 0
90-180 0 0 0
0-180 5565 61.84 100
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
30°
60°
2,250
1,125
3,375
4,500