Lightolier Calculite C4T4VN Specification

®
HID Downlight C4T4VN
Page 1 of 4 4½" Aperture, 2pc Vertical, T4 Narrow Beam
Ceiling Cutout: 5 1/8” (130 mm) Dia.
Reflector Trim Frame-In Kit
C4T4VN
CLW CLP CCDW CCDP CCZW CCZP
Specular Clear, White Painted Flange Specular Clear, Matching Flange Comfort Clear Diffuse, White Painted Flange Comfort Clear Diffuse, Matching Flange Champagne Bronze, White Painted Flange Champagne Bronze, Matching Flange
C420BT5PGJ5E1 C420T4GU65EU C420T4EU C439T4GU65EU C439T4E1 C439T4E2 C470T4E1 C470T4E2
Electronic 120V Electronic 120V/277V Electronic 120V/277V Electronic 120V/277V Electronic 120V Electronic 277V Electronic 120V Electronic 277V
Lamp (Ceramic Metal Halide)
22W Philips MiniMasterColor 20W GE ConstantColor 20W T4.5 39W Philips MiniMasterColor 39W T4.5 39W T4.5 70W T4.5 70W T4.5
Features
1. Upper Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides medium
beam optics ideal for general lighting. Also available in medium and wide beam, see C4T4VM and C4T4VW specification sheets.
2. Aper ture Cone: Provides 50° visual cut-off to lamp and lamp image; self­flange in painted white or aperture-matching polished flange. Consult factory
for other finishes.
3. Lamp Shield: High-temperature glass as required by code, captive during re-lamping. Light diffusion provides exceptionally smooth beam.
4. Socket Housing: Galvanized steel, pre-wired with G8.5 pulse rated socket. Snaps onto upper reflector for secure attachment without tools; unitized construction assures proper lamp alignment to optics for consistent performance.
5. Mounting Frame: 0.048" (18-ga.) galvanized steel. Ver tical adjustment mechanism accommodates mounting to virtually any ceiling system using mounting bars (provided, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be
preset prior to installation.
6. Mounting Ring: 0.048"(18-ga.) galvanized steel. Designed for vertical adjustment from above or below for ceilings from 0" to 2" thick. Center-line notches allow consistent alignment of multiple fixtures.
7. Mounting Bars: 0.048" (18-ga.) pre-installed, telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without
accessories.
8. Trim Retention Springs: Rust resistant springs secure reflector/housing for quick, tool-less installation.
9. Ballast / Socket Housing / Cover Assembly: Snaps onto junction box without tools for inspection and ballast replacement, accessible from below.
10. Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors. Allows inspection from below.
11. Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Electronic Ballast: 120 or 277V, 50/60 Hz., encased, high power
factor, T.H.D. <15%, thermally and transient protected, RMI/RFI complies with FCC Par t 18 non-consumer limits, shut-down circuit at end of lamp life, sound rating “A”, -5°F minimum star ting temperature, Type 1 Outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts
20W MH M156 120/277 0.21/0.10 23 39W MH M130 120/277 0.39/0.17 44 70W MH M139 120/277 0.67/0.29 78
Options and Accessories
Slope Ceiling Adapters: See Specification Sheet SCA. Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Damp Locations), CSA, I.B.E.W. For 70W, install fixtures with minimum spacing bet ween:
1. Center-to center of adjacent luminaries: 2 feet.
2. Top of luminaire to overhead building member: 1/2 inch.
3. Luminaire center to side building member: 1 foot.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0609
1250
1750
2750
5500
®
HID Downlight C4T4VN
Page 2 of 4 4½" Aperture, 2pc Vertical, T4 Narrow Beam
20W T4 GE CMH Lamp, Lumen Rating = 1700 LMS, Aromat Electronic Ballast, CL Finish Trim
CANDL EPOWER DI ST RIBUTION
ANGL E ME AN CP L UMENS 0 23 40 5 20 39 18 9 10 150 5 15 104 7 306
62 5
125 0
18 75
25 00
** EFFI CIENCY = 58.0 %** CER TIFI ED TES T REPO RT NO. 2 401FR , DATE : DEC 22 , 20 03SC = .4 COM PUTE D BY LSI P ROGR AM **T EST-L ITE* *
20 7 20 25 4 90 23 7
60 °
30 3 51 35 2 70 17 3 40 2 09 45 9 6 79 50 6 55 0 1 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
30 °
LUM INANC E SUMMA RY CD. / SQ. M. ANGLE M EAN C D/SQ M 45 132 28 55 32 65 8 75 0 85 0
ZON AL LUM ENS AND PERCE NTAGE S ZONE L UMENS % L AMP %LUM INAIR E 0- 30 7 32 4 3.0 9 74 .35 0-4 0 9 05 53 .24 91.8 7 0- 60 9 85 5 7.95 100 .0 0- 90 9 85 5 7.95 100 .0 40- 90 80 4.7 1 8.13 60- 90 0 0.0 0.0 90 -180 0 0.0 0. 0 0-1 80 9 85 5 7.95 100 .00
Ceiling 80% 70% 50% 30%
Wall 70 5 0 3 0 10 50 10 50 10 50 10 0
RCR Z onal Cavit y Method - Effecti ve Floor C avity Ref lectanc e = 20%
10 .47 .43 .40 .38 .42 .3 8 .42 .38 .42 .3 8 .37
39W T4 Philips CMH Lamp, Lumen Rating = 3300 LMS, Aromat Ballast, CL Finish Trim
CANDL EPOWER DI ST RIBUTION
A NGLE ME AN CP L UMENS 0 33 01 5 29 98 28 1
87 5
175 0
26 25
35 00
** EFFI CIENCY = 57.2%* * CER TIFI ED TES T REPO RT NO. 2 400 FR, DAT E: DEC 2 2, 20 03 SC = . 6 COM PUTE D BY LSI P ROGR AM **T EST-L ITE* *
10 2 493 15 194 6 556 20 146 2 25 106 1 506
60 °
30 78 8 35 60 9 383 40 43 5 45 18 5 158 50 10 55 0 2 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
30 °
LUM INANC E SUMMA RY CD. / SQ. M. ANGLE M EAN C D/SQ M 45 2 554 8 55 0 65 0 75 0 85 0
ZON AL LUM ENS AND PERCE NTAGE S ZONE L UMENS % L AMP %LUM INAIR E 0- 30 134 3 4 0.71 7 1.2 0-4 0 172 6 52 .33 91. 52 0- 60 188 6 5 7.17 10 0 0- 90 188 6 5 7.17 10 0 40- 90 159 4. 85 8.4 8 60- 90 0 0 0 90 -180 0 0 0 0-1 80 188 6 5 7.17 10 0
Ceiling 80% 70% 50% 30%
Wall 70 5 0 3 0 10 50 10 50 10 50 10 0
RCR Z onal Cavit y Method - Effecti ve Floor C avity Ref lectanc e = 20%
10 .45 .40 .38 .36 .40 .3 6 .40 .36 .39 .3 5 .35
Coef ficients of U tilization
0 .69 .69 .69 .69 .67 .6 7 .64 .64 .62 .6 2 .58
1 .67 .65 .64 .63 .64 .6 2 .62 .60 .60 .5 8 .56
2 . 64 .62 .6 0 .59 .61 .58 .5 9 .57 .58 .55 .5 4
3 . 62 .59 .5 7 .55 .58 .55 .5 7 .54 .55 .53 .51
4 . 60 .56 .5 4 .52 .56 .52 .5 4 .51 .53 .50 .4 9
5 .57 .54 .51 .49 .53 .4 9 .52 .48 . 51 .48 .47
6 . 55 . 51 .49 .47 . 51 .47 .50 .46 .4 9 .46 .45
7 . 53 .49 .4 6 .44 .49 .44 .4 8 .44 .47 .44 .4 3
8 .51 .47 .44 .42 .46 . 42 .46 .42 .45 . 42 .41
9 .49 .45 .42 .40 .44 .4 0 .44 .40 .43 .4 0 .39
LUMIN AIRE INPUT WATTS = 23
Coef ficients of U tilization
0 . 68 .68 .6 8 .68 .67 .67 .6 4 .64 .61 .61 .5 7
1 . 66 .64 .6 3 .62 .63 .61 . 61 .59 .59 .58 .5 5
2 . 63 .61 .5 9 .57 .60 .57 .5 8 .56 .57 .55 .5 3
3 .61 .58 .56 .54 .57 .5 3 .56 .52 .54 .5 2 .50
4 . 58 .55 .5 2 .51 .54 .50 .5 3 .50 .52 .49 .4 8
5 . 56 .52 .4 9 .47 .52 .47 .51 .47 .50 .46 .45
6 . 54 .50 . 47 .45 .49 .45 .4 9 .44 .48 .44 .4 3
7 .52 .47 .44 .42 .47 . 42 .46 .42 .45 . 42 .41
8 . 50 .45 . 42 .40 .44 .40 .4 4 .40 .43 .40 .3 9
9 .47 .43 .40 .38 .42 .3 8 .42 .37 .41 . 37 .37
LUMIN AIRE INPUT WATTS = 44
70W T4 Philips CMH Lamp, Lumen Rating = 6 400 LMS, Aromat Electronic Ballast, CL Finish Trim
CANDL EPOWER DI ST RIBUTION
A NGLE ME AN CP L UMENS 0 56 45 5 5 314 49 8
137 5
27 50
4125
5 500
** EFFI CIENCY = 57.0%* * CER TIFI ED TES T REPO RT NO. 2 397 FR, DAT E: DEC 18 , 200 3 SC = . 6 COM PUTE D BY LSI P ROGR AM **T EST-L ITE* *
10 4 588 15 3 673 10 44 20 2 797 25 2 083 9 89
60 °
30 158 2 35 122 0 770 40 87 8 45 38 6 322 50 14 55 0 3 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
30 °
LUM INANC E SUMMA RY CD. / SQ. M. ANGLE M EAN C D/SQ M 45 53 412 55 0 65 0 75 0 85 0
ZON AL LUM ENS AND PERCE NTAGE S
ZONE L UMENS % L AMP %LUM INAIR E 0-3 0 25 30 39 .54 69 .8 0-4 0 3 299 51.5 6 91.0 2 0- 60 3 625 5 6.65 100 0- 90 3 625 5 6.65 100 40- 90 3 25 5.0 9 8.98 60- 90 0 0 0 90 -180 0 0 0 0-1 80 3 625 5 6.65 100
Ceiling 80% 70% 50% 30%
Wall 70 5 0 3 0 10 50 10 50 10 50 10 0
RCR Z onal Cavit y Method - Effecti ve Floor C avity Ref lectanc e = 20%
10 . 44 .39 .3 7 .35 .39 .35 .3 9 .34 .38 .34 .3 4
Coef ficients of U tilization
0 . 68 .68 .6 8 .68 .66 .66 .6 3 .63 .61 .61 .5 7
1 . 65 .64 .6 3 .62 .63 .61 .6 0 .59 .58 .57 .5 4
2 . 63 .60 .5 9 .57 .59 .56 .5 8 .55 .56 .54 .5 2
3 . 60 .57 .5 5 .53 .56 .53 .5 5 .52 .54 . 51 .49
4 . 58 .54 .5 2 .50 .54 .49 .5 3 .49 .51 .48 . 47
5 . 55 . 51 .49 .47 . 51 .46 .50 .46 .4 9 .46 .44
6 . 53 .49 .4 6 .44 .49 .44 .4 8 .44 .47 .43 . 42
7 .51 .46 .43 .42 .46 .41 .45 .41 .45 . 41 .40
8 .49 .44 .41 .39 .43 .3 9 .43 .39 .43 .3 9 .38
9 .46 .42 .39 .37 .41 . 37 . 41 .36 .40 .36 .36
LUMIN AIRE INPUT WATTS = 78
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0609