Lightolier Calculite C4P30D Specification

14 1/4"
Adjustment (mounting bars included)
13 3/4" to 24"
(IC AirSeal
®
C4AIC
10"
Adjustment (mounting bars included)
13 3/4" to 24"
O.A.
20 1/4"
8 1/2"
9 1/2" Dia.
O.A.
14 3/8"
7 3/4"
9 1/2" Dia.
O.A.
12 3/8"
7 3/4"
(Non-IC)
C4120
12 1/2"
(Non-IC AirSeal®)
C4A120
Calculite
1-1/4" Max. Ceiling Thk.
* 7-3/4" min. is for up to 3/4" thick ceiling
7-3/4" min.* 8-1/4" max.
7"
5-3/4" Dia.
4-1/2" Dia.
C4P30DCCDW / C4120 or C4P30DCCDW / C4A120
3
2
4
1
C4P30DCCDW / C4AIC
1/2" to 1" Thk. Ceiling
9-1/4"
5-3/4" Dia.
4-1/2" Dia.
®
Evolution Incandescent Open Downlight C4P30D
Page 1 of 2 4 1/2” Aperture PAR30 Reflector Trim
Ceiling Cutout: 5 1/16" (129 mm) Dia.
Reflector Trim Frame-In Kit
C4P30D CCDW Comfort Clear Diffuse, White Flange Non-IC Non-IC AirSeal® IC-AirSeal C4P30D CCDP Comfort Clear Diffuse, Polished Flange Remodeler
C4P30D
75W PAR30 75W PAR30 75W PAR30 75W PAR30 CCD is the recommended finish.
Short Neck Short Neck Short Neck
Add suffix. See options for other finishes.
Features
1. Trim: 16 ga. aluminum, 50° visual cutoff to lamp and lamp image.
Removable from below for bottom relamping. Available with painted white or polished flange.
2. Reflector Housing: Snaps into frame for easy tool-less installation.
Provides friction spring clips to secure aperture cone. Interchangeable with other Evolution 4" line voltage trims.
3. Socket Harness: Bracket mounted to reflector housing insuring correct opti-
cal alignment. Medium base porcelain socket with nickel plated screw shell, No. 18 SF-1 leads to keyed plug-in quick connector for power connection to junction box.
4. Frame-In Kit: Compatible Frame-In Kits are listed above. Non-IC and Non-IC AirSeal® - Thermal insulation shall not be installed
above a recessed luminaire (fixture) or within 3 in. (75 mm) of the recessed luminaire’s (fixture’s) enclosure or wiring compartment.
IC-AirSeal® - Fixture may be in direct contact with insulation.
Options and Accessories
Reflector Finishes
Clear: CL Gold: GD White: WH
Black: BK Pewter: CPW Comfort Clear Diffuse: CCD Champagne Bronze: CCZ Specify desired flange: W White, P Polished
1
1
®
C4120 C4A120 C4AIC C4120RM
Labels
UL Listed (suitable for damp locations).
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2011 Genlyte Group LLC • C0711
Non-IC
Calculite
®
Evolution Incandescent Open Downlight C4P30D
Page 2 of 2 4 1/2” Aperture PAR30 Reflector Trim
CERTIFIED TEST REPORT NO. 2001FR
COMPUTED BY LSI PROGRAM **TEST-LITE**
CALCULITE 4 1/2" DIA. APERTURE OPEN DOWNLIGHT
CAT. # C4P30DCLP, SPECULAR CLEAR FINISH REFLECTOR
75W PAR30 FLOOD GE LAMP. LUMEN RATING = 1030 LMS.
Candlepower Summary Angle Mean CP Lumens 0 3308 5 3035 278
10 2259 15 1159 361
20 514 25 224 122
30 91
35 36 28 40 16 45 4 5 50 0 55 0 0 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0
90 0
Zonal Lumens And Percentages
Zone Lumens % Lamp %Luminaire
0-30 760 73.82 95.86 0-40 788 76.54 99.39 0-60 793 77.01 100.00 0-90 793 77.01 100.00 40-90 4 .47 .61
Date: Oct. 22, 2002 Prepared for Lightolier, Fall River, MA
Tested According To IES Procedures. Test Distance Exceeds Five
Times The Greatest Luminous Opening Of Luminaire.
60-90 0 .00 .00 90-180 0 .00 .00 0-180 793 77.01 100.00
** Efficiency = 77.0% **
Coefficients of Utilization
80 70 50 30 10 0
% Effective Ceiling Cavity Reflectance
% Wall Reflectance
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .92 .92 .92 .90 .90 .90 .86 .86 .86 .82 .82 .82 .79 .79 .79 .77 1 .88 .87 .86 .87 .85 .84 .83 .82 .82 .80 .80 .79 .78 .77 .77 .76 2 .85 .83 .81 .83 .82 .80 .81 .80 .79 .79 .78 .77 .77 .76 .75
.74
3 .82 .80 .78 .81 .79 .78 .79 .78 .77 .78 .77 .75 .76 .75 .74 .73 4 .80 .78 .76 .79 .77 .75 .78 .76 .74 .76 .75 .74 .75 .74 .73 .72
5 .78 .75 .73 .77 .75 .73 .76 .74 .72 .75 .73 .72 .74 .72 .71 .71
Room Cavity Ratio
6 .76 .73 .72 .76 .73 .71 .75 .73 .71 .74 .72 .71 .73 .71 .70 .70
7 .74 .72 .70 .74 .72 .70 .73 .71 .69 .72 .70 .69 .72 .70 .69 .68 8 .72 .70 .68 .72 .70 .68 .71 .69 .68 .71 .69 .68 .70 .69 .67 .67 9 .71 .69 .67 .71 .69 .67 .70 .68 .67 .70 .68 .66 .69 .67 .66 .66 10 .70 .67 .65 .69 .67 .65 .69 .67 .65 .68 .66 .65 .68 .66 .65. .64
20% Floor Cavity Reflectance
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 201 Genlyte Group LLC • C0711
Loading...