Lightolier Calculite C4MRD CCDW, Calculite C420MREU Specification

®
HID Downlight C4MRD
Page 1 of 2 4 1/2" Aperture (1) 20W CMH MR16
15"
7"
5 3/4"
Side Views
7.41"
Frame-In Kit: C420MREU
Ceiling Cutout: 5 1/16" (129 mm) Dia. Ceiling Thickness: 1 1/8” Max
9.66"
Top View
9.66"
Reflector Trim Frame-In Kit Lamp
Finish White Flange Polished Flange
Comfort Clear Diffuse Comfort Clear
Champagne Bronze
C4MRD CCDW C4MRD CCLW C4MRD CCZW
Features
1. Trim Kit Aperture Cone: 50° visual cut-off to lamp and lamp image. Low
brightness, 0.040” aluminum, anodized; keyed to lamp support assembly
for true aiming of lamp to prevent incorrect installation of cone. Hinged and
snaps on for easy tool-less installation.
2. Lamp Support: Die-form aluminum with knurled surface for easy gripping
during relamping. Spring tension clips hold lamp and lens and allow fast
snap-in, snap-out relamping. Matte black finish.
NOTE: HID lampholder ship with the frame. Discard the incandescent
lampholder that ships standard with the trims.
3. Horizontal Adjustment Mechanism: Die-form steel ring, matte black
finish. Provides 360° horizontal stop, lockable.
4. Frame Vertical Adjustment Mechanism: Accommodates mounting to
virtually any ceiling system using pre-installed mounting bars, or ½” EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. Final adjustment can be made from below inside fixture.
5. Mounting Bars: Galvanized steel, 0.048”; pre-installed telescoping bars
extend to 30” long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bars systems. Self-centering feature simplified installation in 24” O.C. grid systems. Attaches to steel or wood joists without accessories
6. Socket Harness: Twist and lock base. 5kV (600V) pulse rated PPS, black
T240 body socket with nickel-plated contacts. 18 AWG silicone leads with
fiberglass outer sleeve
C4MRD CCDP C4MRD CCLP C4MRD CCZP
C420MREU – Electronic 120/277V Non-IC (1) 20W MR16 CMH GX10 Base
Options and Accessories
Accepts one AL2 or AF2 accessory
Labels
U.L (Suitable for Damp Locations)
®
is a registered trademark of E.I. DuPont.
Tef lo n
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
8"
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2012 Philips Group • B0312
30°
30°
60°
90°
30°
60°
90°
®
HID Downlight C4MRD
Page 2 of 2 4 1/2" Aperture (1) 20W CMH MR16
C4MRDCCLW, 20W G.E. HID SPOT, 12° GX10 BASE
1750
3500
5250
7000
LUMEN RATING = 1000 LMS. SC = .3 TEST REP ORT NO. 3405F R
CANDLEPOWER SUMMARY
Angle Mean CP Lumens
0 6 795 5 5107 457
10 2136
15 803 29 3 20 386 25 207 10 8 30 13 4 35 52 42 40 30 45 16 12 50 0 55 0 0
60 0
65 0 0
70 0
75 0 0 80 0 85 0 0 90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS %LAMP %LUMINAIRE
0- 30 857 85 .75 9 4.06 0- 40 8 99 89.97 9 8.69 0- 60 911 91.16 100.00 0- 90 911 91.16 100.00 40 -90 11 1.19 1.31 60 -90 0 .0 0 .00 90 -180 0 .0 0 .00 0 -180 911 91.16 100.00
LUMINANCE SUMMARY
ANGLE MEAN CD/SQ M
45 2475 55 0 65 0 75 0 85 0
Tested according to IES proc edures. Test distance exceeds five times the greates t luminous opening of luminaire.
C4MRDCCLW, 20W G.E. HID FLOOD, 25° GX10 BASE
750
1500
2250
3000
LUMEN RATING = 1000 LMS. SC = .4 TEST REPORT NO. 3392FR
CANDLEPOWER SUMMARY
Angle Mean CP Lumens
0 3280 5 2896 267 10 2105 15 1316 386 2 0 715 2 5 342 184 3 0 18 7 3 5 9 2 67 40 53 4 5 3 0 22 5 0 0 5 5 0 0
60 0
6 5 0 0
70 0
7 5 0 0 8 0 0 8 5 0 0 9 0 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS %LAMP %LUMINAIRE
0- 30 8 36 83.67 9 0.41 0- 40 9 03 90.33 97.61 0- 60 925 92 .54 100.0 0 0- 90 925 92 .54 100.0 0 40 -90 22 2.21 2.39 60 -90 0 .0 0 .00 90 -180 0 .0 0 .00 0 -180 925 92.54 100.00
LUMINANCE SUMMARY
ANGLE MEAN CD/SQ M
45 4709 55 0 65 0 75 0 85 0
Tested according to IES proc edures. Test distance exceeds five times the greates t luminous opening of luminaire.
** EFFICIENCY = 91.2% **
** EFFICIENCY = 92.5% **
COEFFICIENTS OF UTILIZATION
ZONAL CAVITY METHOD
CC 80 70 50 30 10
WALL 7 0 50 30 10 70 50 30 10 5 0 30 10 50 30 10 50 30 10 0
RCR
0 1.09 1.09 1.09 1.09 1.0 6 1.0 6 1.0 6 1.0 6 1.01 1.01 1.01 .97 .97 .97 .93 .93 .93 .91 1 1.06 1.04 1.03 1.02 1. 04 1. 03 1.01 1.0 0 .99 .9 8 .97 . 95 .95 .94 . 92 .92 .91 . 90 2 1.03 1.01 .98 .9 6 1.01 .99 .9 7 .9 5 .9 6 .9 5 .9 3 .94 .9 3 .92 .91 . 91 .90 . 88 3 1.01 .97 .9 5 .9 3 . 99 .9 6 .9 4 .9 2 . 94 . 92 .91 .92 .91 .9 0 .91 .89 .8 8 .87 4 .99 .9 5 .9 2 .90 .9 8 .94 . 92 .9 0 .92 .9 0 .89 .91 . 89 .88 .89 . 88 .87 .86 5 .97 .9 3 .9 0 .88 .95 . 92 . 89 . 87 . 90 . 88 . 87 .89 . 87 .86 .88 . 87 .85 .84 6 .95 . 91 .88 . 86 .94 .9 0 .8 7 .8 5 .8 9 . 87 .8 5 .88 .86 .84 .87 .85 .84 .83 7 .93 .8 9 .86 . 84 .92 .8 8 .8 6 .8 3 . 87 .8 5 .8 3 .86 .84 .83 .86 .84 .82 .82 8 .92 .8 7 .84 . 82 .91 .8 6 .8 4 .8 2 .8 6 .8 3 .8 2 .85 .83 .81 .84 .83 .81 .80 9 . 90 . 85 . 83 .81 .8 9 .8 5 .8 3 .81 .8 4 .82 . 80 .84 .82 .80 .83 .81 .80 .7 9 10 .88 .8 4 . 81 .79 .8 8 .84 .81 .79 .83 . 81 .79 .8 2 .80 .79 .8 2 .80 .79 .78
CC 80 70 50 30 10
WALL 7 0 50 30 10 70 5 0 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0 1.10 1.10 1.10 1.10 1.0 8 1.0 8 1.0 8 1.0 8 1. 03 1. 03 1.03 .9 8 .98 .98 .9 4 .94 .94 . 93 1 1.07 1.05 1.04 1.02 1.0 5 1. 04 1.02 1.01 1.00 .99 .9 8 .96 .95 .95 .93 .93 .92 .91 2 1.04 1.01 .99 .9 6 1. 02 .9 9 .9 7 .9 5 .9 6 .9 5 .9 3 .94 .93 .91 .92 .91 .90 .88 3 1.01 .97 .9 4 .9 2 1.0 0 .9 6 .9 4 .92 .9 4 .92 . 90 .92 .90 .89 .90 .89 .87 .86 4 . 98 .94 .91 .8 9 . 97 .9 3 . 91 .8 8 . 92 .8 9 .8 7 .90 .88 .86 .88 .87 .85 .84 5 . 96 .91 .88 .8 5 .9 5 .9 0 .8 7 .8 5 .8 9 .8 6 .8 4 .87 .85 .83 .86 .85 .83 .82 6 .94 .8 9 .85 . 83 .93 .8 8 .8 5 .8 3 . 87 .8 4 .8 2 .86 .83 .82 .85 .83 .81 .80 7 .91 .8 6 .8 3 .80 .9 0 .85 . 82 .8 0 .84 .8 2 .80 . 83 .81 .79 . 83 .80 .79 .78 8 .89 .8 3 .80 .78 . 88 . 83 .8 0 .77 .8 2 .79 .77 .81 .79 .77 .81 .78 .77 .76 9 .87 . 81 .78 .76 . 86 .81 .78 .76 .80 .77 .75 .8 0 .77 .75 .79 .76 .75 .74 10 .85 .7 9 .7 6 .73 .8 4 .79 .76 .73 .78 .75 .73 .78 .75 .73 .77 .75 .73 .7 2
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
deter mined in acco rdance wit h current IE S published pr ocedures
deter mined in acco rdance wit h current IE S published pr ocedures
CU VALUE GR EATER THAN 1.00
LUMINAIRE INP UT WATTS = 26.0
COEFFICIENTS OF UTILIZATION
ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
CU VALUE GR EATER THAN 1.00
LUMINAIRE INP UT WATTS = 26.0
C4MRDCCLW, 20W G.E. HID FLOOD, 40° GX10 BASE
90°
CANDLEPOWER SUMMARY
Angle Mean CP Lumens
0 2247
500
1000
1500
2000
LUMEN RATING = 1000 LMS. SC = .6 TEST REP ORT NO. 3391FR
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2012 Philips Group • B0312
5 19 83 187 10 1629 15 130 0 366
60°
2 0 934 2 5 504 255
30 261
3 5 120 88 4 0 6 2 4 5 3 7 27 5 0 5 5 5 1 2
60 1
6 5 1 1
70 0
7 5 0 0 8 0 0 8 5 0 0 9 0 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS %LAMP %LUMINAIRE
0- 30 8 07 80.79 87.15 0-40 89 6 89.63 96.69 0- 60 925 92 .56 9 9.85 0- 90 926 92 .70 100.0 0 40 -90 30 3.07 3.31 60 -90 1 .14 .15 90 -180 0 .0 0 .00 0 -180 926 92.70 100.00
** EFFICIENCY = 92.7% **
LUMINANCE SUMMARY
ANGLE MEAN CD/SQ M
45 5737 55 260 65 211 75 15 7 85 200
Tested according to IES proc edures. Test distance exceeds five times the greates t luminous opening of luminaire.
CC 80 70 50 30 10
WALL 7 0 50 30 10 70 5 0 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0 1.10 1.10 1.10 1.10 1.0 8 1.0 8 1.0 8 1.0 8 1. 03 1. 03 1.03 .9 9 .99 .99 .9 5 .95 .95 . 93 1 1.07 1.05 1.03 1.02 1.0 5 1. 03 1.02 1.00 .99 .9 8 . 97 .96 .95 .94 .93 .92 .92 .90 2 1.03 1.00 .98 .9 5 1. 02 .9 9 .9 6 .9 4 .9 6 .9 4 .9 2 .93 .92 .91 .91 .90 .89 .87 3 1.0 0 .9 6 .9 3 . 91 . 99 .9 5 . 92 .9 0 . 93 .91 .89 .91 .89 .87 .89 .88 .86 .85 4 .97 .9 3 .89 . 87 .96 .9 2 .8 9 .8 6 .9 0 . 87 .8 5 .88 .86 .84 .87 .85 .83 .82 5 .94 .8 9 .85 . 83 .93 .8 8 .8 5 .8 2 . 87 .8 4 .8 2 .86 .83 .81 .84 .82 .80 .79 6 .92 .8 6 .83 . 80 .91 .8 6 .8 2 .8 0 .8 5 .8 2 .79 .8 3 .81 .79 .8 2 .80 .78 .77 7 .89 .8 3 .79 .77 . 88 . 83 .79 .76 .82 .78 .76 .81 .78 .76 .80 .77 .75 .75 8 .87 .8 0 .77 .74 . 86 . 80 .76 .74 .79 .76 .74 .78 .75 .73 .77 .75 .73 .72 9 .84 .7 8 .74 .71 .8 3 .7 7 .74 .71 .76 .73 .71 .76 .73 .71 .75 .72 .70 .70 10 .81 .7 5 .7 2 .69 . 81 .75 .72 .69 .74 .71 .69 .74 .71 .68 .73 .70 .68 .67
deter mined in acco rdance wit h current IE S published pr ocedures
Job Information Type:
COEFFICIENTS OF UTILIZATION
ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
CU VALUE GR EATER THAN 1.00
LUMINAIRE INP UT WATTS = 26.0
Loading...