Lightolier Calculite 8047 Specification

Page 1
Calculite
®
CFL Lensed Wall Washer 8047
Page 1 of 2 7" Aperture Triple Tube Wall Washer
14-1/4"
(362 mm)
(318 mm)
Top View
11-3/8"
(289 mm)
12-1/2"
5-3/4"
(146 mm)
Ceiling Cutout: 8" (203 mm) Dia.
7-3/8"
(187 mm)
1" (25 mm) min.­2-1/8" (54 mm) max.
5
3"
(76 mm)
4
2
7-1/8" (181 mm) Dia.
8-3/8" (213 mm) Self-Flanged Trim
7
6
1-1/8" (29 mm) max. Ceiling Thickness
3
1
Reflector Trim Frame-In Kit
8047 CLW Clear Iridescence Free, White Flange 8047 CLP Clear Iridescence Free, Polished Flange 8047
Add Suffix. See options for other finishes.
S7126BU 7" aperture, 1 lamp 26W Triple Tube CFL (120/277V) 4-Pin (Amalgam) S713 2BU 7" aperture, 1 lamp 26/32W Triple Tube CFL (120/277V) 4-Pin (Amalgam) S7142BU 7" aperture, 1 lamp 26/32/42W Triple Tube CFL (120/277V) 4-Pin (Amalgam)
Dimming Options: S7132B or S714 2B
CU3 Lightolier PowerSpec 3% Dimming (120/277V) J1LD3 Lutron 5% Dimming (120V) J2LD3 Lutron 5% Dimming (277V) JUM7 Mark 7 Dimming (120/277V) J1MX Mark 10 Dimming (120V) J2MX Mark 10 Dimming (277V)
Other dimming product available, please consult factory
Remodeler Frame-In Kits
7126BURM 7" aperture, 1 lamp 26W Triple Tube CFL (120/277V) 4-Pin (Amalgam)) 7132BURM 7" aperture, 1 lamp 26/32W Triple Tube CFL (120/277V) 4-Pin (Amalgam) 7142BURM 7" aperture, 1 lamp 26/32/42W Triple Tube CFL (120/277V) 4-Pin (Amalgam)
Features
1. Optics: Directional prismatic glass spread lens and Alzak® "kick" reflector
direct light smoothly across and down wall. Rotates for correct orientation. Aperture cone with Iridescence Free finish.
2. Socket Cup: Snaps onto reflector neck to assure consistently correct optical
alignment without tools.
4. Retaining Springs: Precision-tooled steel friction springs secure reflector
to mounting frame for quick, tool-less installation.
5. Mounting Brackets: 16 ga. steel. Adjust from inside of fixture. Use 3/4” or
1 1/2” lathing channel, 1/2” EMT, or optional mounting bars.
6. Ballast/J-Box: Outboard mounted to reduce heat transfer and maintain
lamp efficacy and life. Service from below without tools.
7. Torsiontite Springs: Wire formed steel holds reflector/spread lens
assembly snug to housing.
Electrical Note: For ballast electrical data and latest lamp/ballast compatibility refer to “Ballast” specification sheet for complete electrical data.
UL listed for through branch circuit wiring with max of (8) No. 12 AWG, 90° C supply conductors.
Options and Accessories
Comfort Clear™ Finishes1 Other Finishes
Clear CCL White WH Diffuse CCD Specular Clear CL Champagne Bronze CCZ
1
Specify desired flange
W White, P Polished Blank - Molded Ring
Options and Accessories (continued)
Emergency Add suffix EM* Chicago Plenum Add suffix LC Existing/Thk. Ceiling FA EC7* Emergency Ltg. Kit FA EM3E* Fuse (slow blow) Add suffix F *See Spec. Sheets: FAEC, FAEM
Mounting Bars & Accessories; see Specification Sheet MBA. Sloped Ceiling Adapters; see Specification Sheet SCA.
Labels
UL listed for damp locations, I.B.E.W.
Alzak® is a registered trademark of ALCOA.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s): Notes:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2011 Philips Group • C0711
Lightolier is a Philips group brand
Page 2
Calculite
Footcandles On Wall: Multiple 42W Units
Footcandles On Wall: Multiple 32W Units
®
CFL Lensed Wall Washer 8047
Page 2 of 2 7" Aperture Triple Tube Wall Washer
2'
3'
29 f.c.
28 f.c.
EXAMPLE: With multiple clear reflector units located 2' from wall and spaced 3' on center, the illumination on the wall 3' down from ceiling will be 39 f.c. beneath units and 40 f.c. between units.
2' from Wall-2' On Center
2'
1 38 32 38 2 50 49 50 3 43 43 43 4 33 32 33 5 25 32 25 6 20 20 20 7 16 15 16 8 13 13 13 9 11 11 11
Distance From Ceiling in FeetDistance From Ceiling in Feet
3' from Wall-3' On Center 3' from Wall-4' On Center
3'
3'
2' from Wall-3' On Center
3'
1 31 16 31 2 38 28 38 3 29 29 29 4 22 22 22 5 17 17 17 6 13 13 13 7 11 11 11 8 9 9 9 9 7 7 7
4'
3'
3'
36 f.c.
37 f.c.
3'
EXAMPLE: With multiple clear reflector units located 3' from wall and spaced 3' on center, the illumination on the wall 3' down from ceiling will be 36 f.c. beneath units and 37 f.c. between units.
2' from Wall-2' On Center2'2' from Wall-3' On Center
3'
1 61 52 61 2 80 81 80 3 61 62 61 4 44 45 44 5 32 33 32 6 24 25 24 7 19 19 19 8 15 15 15 9 13 13 13
Distance From Ceiling in Feet
1 52 25 52 2 57 51 57 3 40 42 40 4 30 31 30 5 23 23 23 6 18 18 18 7 14 14 14 8 12 12 12 9 10 10 10
Distance From Ceiling in Feet
3' from Wall-3' On Center3'3' from Wall-4' On Center
4'
1 10 9 10 2 21 20 21 3 23 23 23 4 22 22 22 5 19 19 19 6 16 16 16 7 13 13 13 8 11 11 11 9 10 10 10
1 8 6 8 2 17 13 17 3 18 16 18 4 16 16 16 5 14 14 14 6 12 11 12 7 10 9 10 8 8 8 8 9 7 7 7
Distance From Ceiling in Feet Distance From Ceiling in Feet
Footcandle values are averaged and rounded off and based on minimum of five units.
Lightolier is a Philips group brand
1 16 12 16 2 34 32 34 3 36 37 36 4 31 31 31 5 25 26 25 6 21 21 21 7 17 17 17 8 15 15 15 9 13 13 13
Distance From Ceiling in Feet
1 14 8 14 2 29 21 29 3 28 27 28 4 23 24 23 5 19 20 19 6 16 16 16 7 13 14 13 8 12 12 12 9 10 10 10
Distance From Ceiling in Feet
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2011 Philips Group • C0711