Calculite
®
CFL Open Downlight 8038
Page 1 of 2 8" Aperture (2) Triple Tube Horizontal Lamp
2
15-5/8" max.
(397 mm)
5-3/4"
(146 mm)
Top View
Ceiling Cutout: 9 1/4” (2 35 mm) Dia.
12-3/4"
(324 mm)
14"
(356 mm)
(203 mm)
1" (25 mm) min.2-1/8" (54 mm) max.
5
8"
3"
(76 mm)
4
9-3/16" Trimless
(233 mm)
Reflector Trim Frame-In Kits
8038 CLW
8038 CLP
8038 CL
8038
Clear Iridescence Free, White Flange
Clear Iridescence Free, Polished Flange Standard Dimming Options:
Clear Iridescence Free, Molded Trim Ring
Add suffix. See options for other finishes.
S8242HU
S8242H
CU3
J1LD3
J2LD3
JUM7
J1MX
J2MX
Other dimming product available, please consult factory
Remodeler Frame-In Kits
8242HURM
1
6
8-11/16" (226 mm) Dia.
9-7/8" (251 mm)
Self-flange Trim
3
1-1/8" (29 mm) max.
Ceiling Thickness
8" aperture, 2 lamp 26/32/42W Triple Tube CFL (120/277V) 4-Pin (Amalgam)
Lightolier PowerSpec 3% Dimming (120/277V)
Lutron 5% Dimming (120V)
Lutron 5% Dimming (277V)
Mark 7 Dimming (120/277V)
Mark 10 Dimming (120V)
Mark 10 Dimming (277V)
8" aperture, 2 lamp 26/32/42W Triple Tube CFL (120/277V) 4-Pin (Amalgam)
Features
1. Reflector: 16 ga. Specular Alzak® aluminum, 55° visual cutoff to lamp and
lamp image, medium distribution. Iridescence Free finish. Self-flanged or
flangeless with molded white trim ring (field paintable).
2. Socket Bracket: Die-formed steel, vented. Attaches to reflector for correct
optical alignment.
3. Mounting Frame: Die-cast aluminum for dry or plaster ceilings.
4. Retaining Springs: Precision-tooled steel friction springs secure reflector to
mounting frame for quick, tool-less installation.
5. Mounting Brackets: 16 ga. steel. Adjust from inside of fixture. Use 3/4" or
1 1/2" lathing channel, 1/2" EMT, or optional mounting bars.
6. Ballast/J-Box: Outboard mounted to reduce heat transfer and maintain
lamp efficacy and life. Service from below without tools.
Electrical
Note: For ballast electrical data and latest lamp/ballast compatibility refer to
“Ballast” specification sheet for complete electrical data.
UL Listed for through branch circuit wiring with max of (8) No 12 AWG, 90
degree C supply conductors.
Options and Accessories
Comfort Clear™ Finishes1 Other Finishes
Clear CCL White WH
Diffuse CCD
Champagne Bronze CCZ
Pewter CPW
1
Specify desired flange
W White, P Polished
Blank - Molded Ring
Options and Accessories (continued)
Emergency Add suffix EM*
Chicago Plenum Add suffix LC
Emergency Ltg. Kit FA EM3E*
FA EM4E*
Fuse (Slow Blow) Add suffix F
*See Spec. Sheets: FAEM
Mounting Bars & Accessories; see Specification Sheet MBA.
Sloped Ceiling Adapters; see Specification Sheet SCA
Labels
UL listed for damp locations, I.B.E.W.
®
is a registered trademark of ALCOA.
Alzak
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2011 Philips Group • F0711
Lightolier is a Philips group brand

Calculite
®
CFL Open Downlight 8038
Page 2 of 2 8" Aperture (2) Triple Tube Horizontal Lamp
32W
Quick Calculator
100
90
80
70
60
50
40
30
INITIAL FOOTCANDLES
20
10
25 50 75 100 125 150 175 200 225
456 789 10 11 12 13 14 15
AREA PER FIXTURE IN SQUARE FEET
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
This quick calculator chart determines the number and spacing of 2 It. - 32 W PL-T units
with clear reflector: for any level of illumination. For 26W lamps, multiply footcandles
by 0.8.
ROOM SURFACE REFLECTANCES:
80% Ceiling; 50% Wall; 20% Floor
2400 Lumens Per Lamp
RCR= 1 (Rm. Width= 10xMtg. Ht. above work plane)
RCR= 5 (Rm. Width= 2xMtg. Ht. above work plane)
RCR=10 (Rm. Width= Mtg. Ht. above work plane)
Spacing Ratio: Along = 1.4 Across = 1.6
CERTIFIED TEST REPORT N0. ITL44462
INDEPENDENT TESTING LABORATORIES, INC.
RECESSED CALCULITE DOWNLIGHT
8-11/16" APERTURE SPECULAR CLEAR REFLECTOR
TWO PHILIPS 32-WATT 32W/35/4P TRIPLE U-TUBE. COMPACT FLUORESCENTS.
1400
2100
DATE: Dec 4, 1995
HORIZONTAL POSITION. LUMEN RATING =2400 LMS
ANGLE 0.0 45.0 90.0 135.0 180.0 FLUX
90
75
700
60
45
15
0
0-deg:
90-deg:
180-deg:
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE
GREATEST LUMINOUS OPENING OF LUMINAIRE.
30
CANDLEPOWER SUMMARY
0 1499 1499 1499 1499 1499
5 1502 1555 1643 1573 1426 152
15 1546 1829 2017 1862 1330 505
25 1628 2073 2090 1747 1440 844
35 1312 1820 1842 1573 1242 1007
45 823 1034 1242 1222 1181 849
55 31 55 61 58 61 118
65 2 23223
75 1 11111
85 0 00000
90 0 0000
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 1500 31.3 43.1
0-40 2508 52.2 72.1
0-60 3475 72.4 99.9
0-90 3479 72.5 100.0
90-180 0 0.0 0.0
0-180 3479 72.5 100.0
** EFFICIENCY = 72.5% **
Coefficients of Utilization
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50 30 10 0
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
179 .77 .75 .78 .76 .74 .75 .73 .72 .72 .71 .70 .69 .68 .68 .66
2 .72 .69 .66 .71 .68 .65 .69 .66 .64 .66 .64 .62 .64 .62 .61 .60
3 .66 .62 .58 .65 .61 .58 .63 .59 .57 .61 .58 .56 .59 .57 .55 .54
4 .60 .55 .52 .59 .55 .51 .58 .54 .51 .56 .53 .50 .55 .52 .49 .48
5 .55 .50 .46 .54 .49 .46 .53 .49 .45 .51 .48 .45 .50 .47 .44 .43
6 .50 .45 .41 .50 .45 .41 .48 .44 .41 .47 .43 .40 .46 .43 .40 .39
7 .46 41 .37 .46 .41 .37 .45 .40 .37 .44 .40 .37 .43 .39 .36 .35
8 .42 .37 .34 .42 .37 .34 .41 .37 .33 .40 .36 .33 .40 .36 .33 .32
ROOM CAVITY RATIO
9 .39 .34 .31 .39 .34 .31 .38 .34 .30 .37 .33 .30 .37 .33 .30 .29
10 .36 .31 .28 .36 .31 .28 .35 .31 .28 .35 .31 .28 .34 .30 .28 .26
% WALL REFLECTANCE
20% FLOOR CAVITY REFLECTANCE
For 26W lamps, multiply C.U.'s by 1.1.
42W
Quick Calculator
100
90
80
70
60
50
40
30
INITIAL FOOTCANDLES
20
10
25 50 75 100 125 150 175 200 225
AREA PER FIXTURE IN SQUARE FEET
456 789 10 11 12 13 14 15
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
This quick calculator chart determines the number and spacing of 2 It. - 42 Watt PL-T
units with clear reflector: for any level of illumination.
ROOM SURFACE REFLECTANCES:
80% Ceiling; 50% Wall; 20% Floor
3200 Lumens Per Lamp
RCR= 1 (Rm. Width= 10xMtg. Ht. above work plane)
RCR= 5 (Rm. Width= 2xMtg. Ht. above work plane)
RCR=10 (Rm. Width= Mtg. Ht. above work plane)
Spacing Ratio: Along = 1.4 Across = 1.7
CERTIFIED TEST REPORT N0. ITL44463
INDEPENDENT TESTING LABORATORIES, INC.
RECESSED CALCULITE DOWNLIGHT 8038CLIF/8242HE120
8 ? " APERTURE SPECULAR CLEAR REFLECTOR
TWO PHILIPS 42-WATT PL-T 42W/4P TRIPLE U-TUBE. COMPACT FLUORESCENTS.
HORIZONTAL POSITION. LUMEN RATING =3200 LMS
NDLE POWER SUMMARY
CA
ANGLE 0.0 45.0 90.0 135.0 180.0 FLUX
0 1800 1800 1800 1800 1800
90
5 1748 1821 1960 1951 1817 184
15 1695 2065 2423 2380 1892 616
25 1828 2305 2516 2461 2082 1048
75
35 1505 2016 2330 2138 1821 1264
800
1600
2400
15
0
0-deg:
90-deg:
180-deg:
DATE: Jan 3, 1996
PREPARED FOR:
LIGHTOLIER, Fall River, MA
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE
GREATEST LUMINOUS OPENING OF LUMINAIRE.
45 1135 1419 1505 1454 1366 1063
55 49 83 63 53 46 142
65 4333
60
75 1111
85 0000
90 0000 0
ZONAL LUMENS AND PERCENTAGES
45
ZONE LUMENS % LAMP %LUMINAIRE
0-30 1847 28.9 42.8
0-40 3112 48.6 72.0
0-60 4316 67.4 99.9
0-90 4320 67.5 100.0
90-180 0 0.0 0.0
30
0-180 4320 67.5 100.0
** EFFICIENCY = 67.5% **
Coefficients Of Utilization
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50 30 10 0
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .74 .72 .70 .72 .70 .69 .69 .68 .67 .67 .66 .65 .65 .64 .63 .62
2 .67 .64 .61 .66 .63 .61 .64 .61 .59 .62 .60 .58 .60 .58 .57 .56
3 .61 .57 .54 .60 .57 .54 .58 .55 .53 .57 .54 .52 .55 .53 .51 .50
4 .56 .51 .48 .55 .51 .48 .54 .50 .47 .52 .49 .46 .51 .48 .46 .45
5 .51 .46 .43 .50 .46 .43 .49 .45 .42 .48 .44 .42 .47 .44 .41 .40
6 .47 .42 .38 .46 .42 .38 .45 .41 .38 .44 .40 .38 .43 .40 .37 .36
7 .43 .41 .37 .46 .41 .37 .45 .40 .37 .44 .40 .37 .43 .39 .36 .35
8 .39 .35 .31 .39 .34 .31 .38 .34 .31 .37 .34 .31 .37 .33 .31 .30
9 .36 .32 .28 .36 .31 .28 .35 .31 .28 .35 .31 .28 .34 .31 .28 .27
ROOM CAVITY RATIO
10 .34 .29 .26 .33 .29 .26 .33 .29 .26 .32 .28 .26 .32 .28 .26 .25
% WALL REFLECTANCE
20% FLOOR CAVITY REFLECTANCE
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2011 Philips Group • F0711
Lightolier is a Philips group brandLightolier is a Philips group brand