Lightolier C9E28VN User Manual

Calculite
9
7
14
9-1/2" (241 mm) Dia.
2" (50 mm) max. Ceiling Thickness
8
11
5
6
Vertical Adjustment: 5/8" (16 mm) to 2 7/8" (73 mm)
2
10
3
17-1/8" (435 mm)
10-3/4" (273 mm) Dia.
®
HID Downlight C9E28VN
Page 1 of 2 9" Aperture, ED28 (Enclosed), Metal Halide, Narrow Beam
Ceiling Cutout: 10 1/16” (256 mm) Dia.
Reflector Trim Frame-In Kit Lamp (Coated)
C9E28VN CLW Specular Clear, White Painted Flange.
CLP Specular Clear, Matching Flange. CCDW Comfort Clear Diffuse, White Painted Flange. CCDP Comfort Clear Diffuse, Matching Flange. CCZW Champagne Bronze, White Painted Flange. CCZP Champagne Bronze, Matching Flange.
C917MHPSU Magnetic Pulse Start, 120V/277V 175W ED28, BT28 (Enclosed), PS MH C925MHPSU Magnetic Pulse Start, 120V/277V 250W ED28, BT28 (Enclosed), PS MH C917MHU Magnetic, 120V/277V 175W ED28, BT28 (Enclosed), MH C925MHU Magnetic, 120V/277V 250W ED28, BT28 (Enclosed), MH
Features
1. Upper Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides
narrow beam optics. Also available in wide beam, see C9E28VW
specification sheets.
2. Aperture Cone: Low brightness with 40° cut-off to lamp and lamp image.
Self-flanged painted white or aperture matching polished flange. Consult factory for other finishes.
3. Lamp Shield: High-temperature glass as required by code, captive
during re-lamping..
4. Socket Cup: Heat dissipating, die-cast aluminum, pre-wired with mogul base
porcelain socket with nickel plated screw shell. Postive locking attachment without tools to reflector assures proper optical alignment of lamp.
5. Mounting Frame: 0.048" (18-ga.) galvanized steel, includes pre-installed
mounting bar.
6. Mounting Ring: 0.048"(18-ga.) galvanized steel. Designed for vertical
adjustment from above or below for ceilings from 0" to 2" thick. Center-line notches allow consistent alignment of multiple fixtures.
7. Trim Retention Springs: Rust resistant springs secure cone for quick,
tool-less installation.
8. Frame Vertical Adjustment: Vertical adjustment mechanism accommodates
mounting to virtually any ceiling system using mounting bars (provided, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be preset prior to installation.
9. Mounting Bars: 0.048" (18-ga.) pre-installed, telescoping bars extend to 30" long
and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories.
10. Ballast Assembly: Ballast and mounting plate on mounting bars secured
with thumb screw. Ballast assembly is accessible from below without tools for inspection and replacement.
11. Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90°C through branch circuit conductors. Allows inspection from below.
12. Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not
install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted,
HX-HPF circuit type, high power factor, sound rating “B”, -20°F minimum starting temperature, Type 1 Outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts
175W PS MH M137/M152 120/277 2.20/0.90 205 250W PS MH M138/M153 120/277 2.80/1.20 290 175W MH M57 120/277 2.00/0.90 205 250W MH M58 120/277 2.60/1.10 290
Options and Accessories
Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. See Spec.Sheet ”A“. Emergency Lamp: Add suffix E to Reflector Trim and Frame-In Kit. See Spec.
Sheet “E”.
Slope Ceiling Adapters: See Specification Sheet SCA. Fuse (Magnetic Ballast): Add suffix F1 or F2 to Frame in Kit (F1=120V,
F2=277V).
Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Damp Locations), CSA, I.B.E.W.
Job Information Type:
Job Name: Cat. No.:
Lamp(s): Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4
Calculite
®
HID Downlight C9E28VN
Page 2 of 2 9" Aperture, ED28 (Enclosed), Metal Halide, Narrow Beam
175W ED28, PHILIPS MH COATED LAMP, LUMEN RATING = 12900 LMS, ADVANCE MAGNETIC BALLAST, CL FINISH TRIM
CANDLEPOWER DISTRIBUTION
ANGLE MEAN CP LUMENS
0 9482 5 8632 809
10 7160
2,250
4,500
6,750
9,000
** EFFICIENCY = 48.0% ** CERTIFIED TEST REPORT NO. 2450FR, DATE: FEB 12, 2004
15 6075 1726 20 5041 25 3948 1829
60°
30 2866 35 1919 1239 40 1185 45 666 530 50 218 55 23 60 60 3 65 1 1 70 0 75 0 0 80 0 85 0 0 90 0
30°
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 23031 55 988 65 78 75 32 85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 4363 33.82 70.45 0-40 5602 43.43 90.45 0-60 6191 48 99.97
0-90 6193 48.01 100.00 40-90 591 4.58 9.55 60-90 1 0.01 0.03
90-180 0 0 0
0-180 6193 48.01 100.00
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .57 .57 .57 .57 .56 .56 .53 .53 .51 .51 .48 1 .55 .54 .53 .52 .53 .51 .51 .49 .49 .48 .46 2 .53 .51 .49 .48 .50 .47 .48 .46 .47 .45 .44 3 .51 .48 .46 .45 .47 .44 .46 .44 .45 .43 .42 4 .49 .46 .44 .42 .45 .42 .44 .41 .43 .41 .40 5 .47 .43 .41 .39 .43 .39 .42 .39 .41 .38 .37 6 .45 .41 .39 .37 .41 .37 .40 .37 .40 .36 .36 7 .43 .39 .37 .35 .39 .35 .38 .35 .38 .34 .34 8 .41 .37 .35 .33 .37 .33 .36 .33 .36 .32 .32 9 .39 .35 .33 .31 .35 .31 .34 .31 .34 .31 .30 10 .37 .33 .31 .29 .33 .29 .33 .29 .32 .29 .28
SC = .6 COMPUTED BY LSI PROGRAM **TEST-LITE**
250W ED28, PHILIPS MH COATED LAMP, LUMEN RATING = 19475 LMS, UNIVERSAL MAGNETIC BALLAST, CL FINISH TRIM
CANDLEPOWER DISTRIBUTION
ANGLE MEAN CP LUMENS
0 11750
5 11130 1042 10 9674 15 8222 2335 20 6835 25 5292 2464
60°
30 3878 35 2612 1680
6,000
12,000
** EFFICIENCY = 42.7% ** CERTIFIED TEST REPORT NO. 2460FR DATE:, FEB 19, 2004
SC = .7 COMPUTED BY LSI PROGRAM **TEST-LITE**
40 1598 45 900 716 50 299 55 23 77 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
30°
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 31142 55 999 65 0 75 0 85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 5842 30 70.25 0-40 7522 38.63 90.46 0-60 8315 42.7 100
0-90 8315 42.7 100 40-90 793 4.07 9.54 60-90 0 0 0
90-180 0 0 0
0-180 8315 42.7 100
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .51 .51 .51 .51 .50 .50 .47 .47 .45 .45 .43 1 .49 .48 .47 .46 .47 .45 .45 .44 .44 .43 .41 2 .47 .45 .44 .43 .44 .42 .43 .41 .42 .40 .39 3 .45 .43 .41 .40 .42 .39 .41 .39 .40 .38 .37 4 .43 .41 .39 .37 .40 .37 .39 .37 .38 .36 .35 5 .41 .39 .36 .35 .38 .35 .37 .34 .37 .34 .33 6 .40 .37 .34 .33 .36 .33 .36 .33 .35 .32 .32 7 .38 .35 .32 .31 .34 .31 .34 .31 .33 .30 .30 8 .36 .33 .31 .29 .32 .29 .32 .29 .32 .29 .28 9 .35 .31 .29 .27 .31 .27 .30 .27 .30 .27 .27 10 .33 .30 .27 .26 .29 .26 .29 .26 .29 .26 .25
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
LUMINAIRE INPUT WATTS = 205
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
LUMINAIRE INPUT WATTS = 290
Job Information Type:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4