Lightolier C7P38MH User Manual

Calculite
®
HID Downlight C12E28VW
Page 1 of 2 12" Aperture, ED28 (Enclosed) Metal Halide, Wide Beam
Ceiling Cutout: 12 9/16” (256mm) Dia.
Reflector Trim Frame-In Kit Lamp (Enclosed, Coated)
C12E28VW CLW Specular Clear,White Painted Flange.
CLP Specular Clear,Matching Flange. CCDW Comfort Clear Diffuse, White Painted Flange. CCDP Comfort Clear Diffuse, Matching Flange. CCZW Champagne Bronze, White Painted Flange. CCZP Champagne Bronze, Matching Flange.
C1217MHPU Magnetic, Pulse Start, 120V/277V 175W ED28, BT28 PS MH C1225MHPU Magnetic, Pulse Start, 120V/277V 250W ED28, BT28 PS MH C1232MHPU Magnetic, Pulse Start, 120V/277V 320W ED28, BT28 PS MH C1240MHPU Magnetic, Pulse Start, 120V/277V 400W ED28, BT28 PS MH C1217MHU Magnetic, 120V/277V 175W ED28, BT28 MH C1225MHU Magnetic, 120V/277V 250W ED28, BT28 MH C1240MHU Magnetic, 120V/277V 400W ED28, BT28 MH
Features
1. Upper Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides wide
beam optics ideal for general lighting. Also available in narrow beam, see C12E28VN specification sheet.
2. Aperture Cone: Low brightness with 40° cut-off to lamp. Specular Clear or Comfort Clear™ Diffuse, or champagne bronze self-flanged in painted white or aperture-matching polished flange. Consult factory for other finishes.
3. Lamp Shield: High-temperature glass as required by code, captive during
re-lamping.
4. Socket Cup: Heat dissipating, die-cast aluminum, pre-wired with mogul base porcelain socket with nickel plated screw shell. Postive locking attachment without tools to reflector assures proper optical alignment of lamp.
5. Mounting Frame: 0.048" (18-ga.) galvanized steel, includes pre-installed mounting bars.
6. Mounting Ring: 0.048"(18-ga.) galvanized steel. Designed for vertical adjustment from above or below for ceilings from 0" to 2" thick. Center-line notches allow consistent alignment of multiple fixtures.
7. Retention Springs: Rust resistant springs secure cone for quick, tool-less installation.
8. Frame Vertical Adjustment: Vertical adjustment mechanism accommodates mounting to virtually any ceiling system using mounting bars (provided, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be preset prior to installation.
9. Mounting Bars: 0.048" (18-ga.) pre-installed, telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories.
10. Ballast: Pulse Start
11.Junction Box: 0.059" (16-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90°C through branch circuit conductors. Allows inspection from below.
12.Thermal Protector: Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, CWA or
Super CWA (pulse start) circuit type, high power factor, sound rating “B” (175W and 250W PS)/sound rating “C” (others), -20°F minimum starting Temperature, Type 1 Outdoor rating.
Electrical (cont.)
Ballast ANSI Code Voltage Max. Amps Input Watts
175W PS MH M137 120/277 2.20/0.90 205 250W PS MH M138 120/277 2.80/1.20 290 320W PS MH M132 120/277 3.40/1.50 370 400W PS MH M135 120/277 4.10/1.80 465 175W MH M57 120/277 2.00/0.90 205 250W MH M58 120/277 2.60/1.10 290 400W MH M59 120/277 3.90/1.70 460
Options and Accessories
Auxiliary: Add suffix Ato Frame-In Kit and Reflector Trim. See Spec.Sheet ”A“. Emergency: Add suffix E to Reflector Trim and Frame-In Kit. See Spec. Sheet “E”. Slope Ceiling Adapters: See Specification Sheet SCA. Fuse (magnetic ballast): Add suffix F1 orF2 to Frame in Kit (F1=120V, F2=277V). Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Damp Locations), CSA, I.B.E.W. For 320W/400W, install fixtures with minimum spacing: 4 feet from center-to­center of adjacent luminaries; 3 inch from top of luminaire to overhead building member; 2 feet from luminaire center to side building member.
Job Information Type:
Job Name: Cat. No.:
Lamp(s): Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4
Calculite
®
HID Downlight C12E28VW
Page 1 of 2 12" Aperture, ED28 (Enclosed) Metal Halide, Wide Beam
175W ED28 G.E. MH COATED LAMP, LUMEN RATING = 12900 LMS, ADVANCE MAGNETIC BALLAST, CL FINISH TRIM
1,375
2,750
4,125
5,500
* ** EFFICIENCY = 61.8% ** CERTIFIED TEST REPORT NO. 2505FR, DATE: MAR 14, 2004 SC = 1.1 COMPUTED BY LSI PROGRAM **TEST-LITE**
250W ED28 PHILIPS MH COATED LAMP, LUMEN RATING = 19475 LMS, UNIVERSAL MAGNETIC BALLAST, CL FINISH TRIM
2,125
4,250
6,375
8,500
** EFFICIENCY = 62.4% ** CERTIFIED TEST REPORT NO. 2508FR, DATE: MAR 14, 2004 SC = 1.1 COMPUTED BY LSI PROGRAM **TEST-LITE*
320W ED28 PHILIPS MH COATED LAMP, LUMEN RATING = 30100 LMS, ADVANCE BALLAST PULSE START MAGNETIC, CL FINISH TRIM
2,750
5,500
8,250
11,000
*** EFFICIENCY = 55.7% ** CERTIFIED TEST REPORT NO. 2413FR, DATE: FEB 10, 2004 SC = 1.2 COMPUTED BY LSI PROGRAM **TEST-LITE**
400W ED28 G.E. MH COATED LAMP. LUMEN RATING = 35000 LMS, ADVANCE MAGNETIC BALLAST, CL FINISH TRIM
5,000
10,000
15,000
20,000
** EFFICIENCY = 64.2% ** CERTIFIED TEST REPORT NO. 2521FR, DATE: MAR 14, 2004
SC = 1.1 COMPUTED BY LSI PROGRAM **TEST-LITE**
ANGLE MEAN CP LUMENS
0 5034
5 5057 489 10 5362 15 5266 1459 20 4701
60°
25 4237 1967 30 3820 35 3715 2249 40 3070 45 2096 1574 50 866 55 85 233 60 2 65 0 1 70 0 75 0 0 80 0
85 0
30°
90 0
ANGLE MEAN CP LUMENS
0 8217
5 8229 788 10 8325 15 8132 2277 20 7546
60°
25 6737 3109 30 5850 35 5457 3333 40 4459 45 3040 2289 50 1286 55 130 348 60 4 65 0 1 70 0 75 0 0 80 0 85 0 0
30°
90 0
ANGLE MEAN CP LUMENS
0 10325
5 10384 994 10 10573 15 10304 2894 20 9659
60°
25 8898 4099 30 7970 35 7756 4746 40 6738 45 4730 3513 50 1945 55 198 526 60 4 65 0 1 70 0 75 0 0 80 0 85 0 0
30°
90 0
ANGLE MEAN CP LUMENS
0 14097
5 14418 1399 10 15675 15 15612 4282 20 13529
60°
25 11653 5440 30 10175 35 10432 6250 40 8760 45 6008 4499 50 2461 55 137 614 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0
30°
90 0
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 72490 55 3628 65 0 75 0
50
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 3915 30.35 49.12 0-40 6164 47.79 77.33 0-60 7970 61.79 99.99
0-90 7971 61.79 100 40-90 1807 14.01 22.67 60-90 0 0 0.01
90-180 0 0 0
0-180 7971 61.79 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 105132 55 5546 65 0 75 0 85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 6174 31.7 50.84
0-40 9507 48.82 78.28
0-60 12143 62.36 99.99
0-90 12144 62.36 100 40-90 2637 13.54 21.72 60-90 0 0 0.01
90-180 0 0 0
0-180 12144 62.36 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 92020 55 4756 65 0 75 0 85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 7987 26.54 47.62
0-40 12733 42.3 75.92
0-60 16771 55.72 99.99
0-90 16772 55.72 100 40-90 4039 13.42 24.08 60-90 1 0 0.01
90-180 0 0 0
0-180 16772 55.72 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 207807
5 5858 65 0 75 0 85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 11120 31.77 49.46 0-40 17370 49.63 77.26 0-60 22483 64.24 100
0-90 22483 64.24 100 40-90 5112 14.61 22.74 60-90 0 0 0
90-180 0 0 0
0-180 22483 64.24 100
Job Information Type:
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .74 .74 .74 .74 .72 .72 .69 .69 .66 .66 .62 1 .70 .68 .67 .65 .67 .64 .64 .62 .62 .60 .58 2 .67 .64 .61 .59 .63 .58 .60 .57 .59 .56 .54 3 .63 .59 .56 .53 .58 .53 .57 .52 .55 .51 .50 4 .60 .55 .52 .49 .54 .49 .53 .48 .52 .48 .46 5 .56 .51 .47 .45 .50 .44 .49 .44 .48 .44 .42 6 .53 .47 .44 .41 .47 .41 .46 .40 .45 .40 .39 7 .50 .44 .40 .37 .43 .37 .42 .37 .42 .36 .35 8 .47 .40 .36 .34 .40 .33 .39 .33 .39 .33 .32 9 .44 .37 .33 .30 .37 .30 .36 .30 .36 .30 .29 10 .41 .34 .30 .27 .34 .27 .33 .27 .33 .27 .26
LUMINAIRE INPUT WATTS = 205.0
Coefficients of Utilization
Coefficients of Utilization
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .74 .74 .74 .74 .73 .73 .69 .69 .66 .66 .62 1 .71 .69 .67 .66 .68 .65 .65 .63 .63 .61 .58 2 .67 .64 .62 .60 .63 .59 .61 .58 .59 .57 .54 3 .64 .60 .57 .54 .59 .54 .57 .53 .56 .52 .50 4 .61 .56 .52 .50 .55 .49 .54 .49 .53 .48 .47 5 .57 .52 .48 .45 .51 .45 .50 .45 .49 .44 .43 6 .54 .48 .44 .42 .48 .42 .47 .41 .46 .41 .40 7 .51 .45 .41 .38 .44 .38 .43 .38 .43 .37 .36 8 .48 .41 .37 .35 .41 .34 .40 .34 .40 .34 .33 9 .45 .38 .34 .31 .38 .31 .37 .31 .37 .31 .30 10 .42 .35 .31 .28 .35 .28 .34 .28 .34 .28 .27
LUMINAIRE INPUT WATTS = 290.0
Coefficients of Utilization
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .66 .66 .66 .66 .65 .65 .62 .62 .59 .59 .56 1 .63 .62 .60 .59 .60 .58 .58 .56 .56 .54 .52 2 .60 .57 .55 .53 .56 .52 .54 .51 .53 .50 .48 3 .57 .53 .50 .48 .52 .48 .51 .47 .50 .46 .45 4 .54 .49 .46 .44 .49 .43 .48 .43 .46 .43 .41 5 .51 .46 .42 .40 .45 .40 .44 .39 .43 .39 .38 6 .48 .42 .39 .36 .42 .36 .41 .36 .40 .36 .35 7 .45 .39 .35 .33 .39 .33 .38 .33 .37 .32 .31 8 .42 .36 .32 .30 .35 .30 .35 .30 .34 .29 .28 9 .39 .33 .29 .27 .33 .27 .32 .27 .32 .26 .26 10 .36 .30 .27 .24 .30 .24 .29 .24 .29 .24 .23
LUMINAIRE INPUT WATTS = 370.0
Coefficients of Utilization
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .76 .76 .76 .76 .75 .75 .71 .71 .68 .68 .64 1 .73 .71 .69 .68 .70 .67 .67 .65 .65 .63 .60 2 .69 .66 .64 .61 .65 .61 .63 .59 .61 .58 .56 3 .66 .61 .58 .56 .61 .55 .59 .54 .57 .54 .52 4 .62 .57 .54 .51 .57 .51 .55 .50 .54 .50 .48 5 .59 .53 .49 .46 .53 .46 .51 .46 .50 .45 .44 6 .55 .49 .45 .43 .49 .42 .48 .42 .47 .42 .41 7 .52 .46 .42 .39 .45 .38 .44 .38 .43 .38 .37 8 .49 .42 .38 .35 .42 .35 .41 .35 .40 .35 .34 9 .46 .39 .35 .32 .38 .32 .38 .32 .37 .31 .30 10 .43 .36 .32 .29 .35 .29 .35 .29 .34 .28 .27
LUMINAIRE INPUT WATTS = 460
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4
Loading...