Lightolier C7E17OW User Manual

Calculite
®
HID Wall Wash C7E17OW
Page 1 of 2 7” Aperture, ED17 (Open Rated) Ceramic Metal Halide
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Group LLC • B1004
Features
1. Downlight/Wall Washer Reflector Trim: Anodized aluminum, 0.040” (16-
ga.). Provides vertical surface wall washing and medium beam downlighting; 50° visual cut-off to lamp and lamp image; self-flange in painted white or aperture-matching polished flange. Consult factory for other finishes.
2. Socket Housing: Galvanized steel, pre-wired with medium base pulse rated
socket. Snaps onto upper reflector for secure attachment without tools; assures proper lamp alignment to optics for consistent performance.
3. Mounting Frame: 0.048" (18-ga.) galvanized steel includes pre-installed
mounting bars.
4. Mounting Ring: 0.048" (18-ga.) galvanized steel. Designed for vertical
adjustment from above or below for ceilings from 0" to 2" thick. Center-line notches allow consistent alignment of multiple fixtures.
5. Retention Springs: Rust resistant springs secure reflector in place for quick,
tool-less installation.
6. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism
accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation.
7. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to 30"
long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories.
8. Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V).
Accessible from below for inspection and/or replacement without tools.
9. Junction Box: 0.059" (16-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90°C through branch circuit conductors; allows inspection from below.
10.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not
install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high-power factor, T.H.D.
<15%, thermally and transient protected, RMI / RFI complies with FCC Part 18 non-consumer equipment, shut-down circuit at end of lamp life, sound rating "A", -5°F (-20°F for 150W) minimum starting temperature, Type 1 outdoor rating.
Electrical (cont)
Ballast ANSI Code Voltage Max. Amps Input Watts
70W MH M98/M143 120/277 0.67/0.28 78 100W MH M90/M140 120/277 0.90/0.43 110 150W MH M102 120/277 1.40/0.61 167
Magnetic Ballast: 120V/277V dual voltage, 60 Hz., encased and potted, HX-HPF circuit type, high power factor, sound rating “B”, -20°F minimum starting temperature, Type 1 Outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts
70W MH M98/M143 120/277 1.90/0.80 94 100W MH M90/M140 120/277 2.40/1.10 125 150W MH M102 120/277 3.70/1.60 180
Options and Accessories
Fuse: Add suffix F1 or F2 to Frame-In Kit (F1=120V, F2=277V) Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Damp Locations), I.B.E.W. For 150W, install fixtures with minimum spacing between:
1. Center-to-center of adjacent luminaries: 3 feet.
2. Top of luminaire to overhead building member: 3 inch.
3. Luminaire center to side building member: 1 1/2 feet.
Reflector Trim Frame-In Kit Lamp
(Coated, Ceramic MH)
C7E17OW CLW Specular Clear, White Painted Flange. C770MHOE1 Electronic 120V / C770MHOE2 Electronic 277V 70W E17, ED17, BD17 (Open Rated)
CLP Specular Clear, Matching Flange. C710MHOE1 Electronic 120V / C710MHOE2 Electronic 277V 100W E17, ED17, BD17 (Open Rated) CCDW Comfort Clear Diffuse, White Painted Flange. C715MHOE1 Electronic 120V / C715MHOE2 Electronic 277V 150W E17, ED17, BD17 (Open Rated) CCDP Comfort Clear Diffuse, Matching Flange. C770MHOU Magnetic 120V/277V 70W E17, ED17, BD17 (Open Rated) CCZW Champagne Bronze, White Painted Flange. C710MHOU Magnetic 120V/277V 100W E17, ED17, BD17 (Open Rated) CCZP Champagne Bronze, Matching Flange. C715MHOU Magnetic 120V/277V 150W E17, ED17, BD17 (Open Rated)
Ceiling Cutout: 8” (203mm) Dia.
20" (508 mm) to 30" (762 mm)
8-1/4"
9-3/4"
(210 mm)
(248 mm)
10-1/2"
(267 mm)
18-5/8" (473 mm)
(Magnetic Ballast)
20" (508 mm) to 30" (762 mm)
10-7/8"
(276 mm)
Top View
(Electronic Ballast)
Top View
9-3/4" (248 mm)
11" (280 mm)
(100/150W)
10-7/8"
(276 mm)
9-7/8"
(251 mm)
8
6
2
7-1/8" (181 mm) Dia.
1
8
5 3 9 7
4
2" (50 mm) max. Ceiling Thickness
Vertical Adjustment: 5/8" (16 mm) to 2 7/8" (73 mm)
Calculite
®
HID Wall Wash C7E17OW
Page 2 of 2 7” Aperture, ED17 (Open Rated) Ceramic Metal Halide
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Group LLC • B1004
Job Information Type:
CANDLEPOWER DISTRIBUTION
70W ED17 PHILIPS COATED CERAMIC MH, 3K. LUMEN RATING = 5700 LMS., AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM, REPORT NO. 2343FR
Multiple Units -
Footcandles On Wall
3' from Wall - 3' On Center
1 40.8 35.4 40.8 2 53.2 49.6 53.2 3 50.4 50.7 50.3 4 45.3 46.2 45.3 5 42.4 42.9 42.4 6 38.1 39.1 38.1 7 33.9 34.7 33.9 8 30.2 30.5 30.2
9 27.2 27.1 27.2 10 24.5 24.3 24.5 11 22.2 22.0 22.2 12 20.5 20.3 20.5 13 19.2 19.1 19.2 14 18.4 18.4 18.4
30°
60°
Downlight Side
Wall Wash
Side
Distance From Ceiling in Feet
3'
1,705
3,500
100W ED17 PHILIPS COATED CERAMIC MH, 3K. LUMEN RATING = 8500 LMS., AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM, REPORT NO. 2344FR
Multiple Units -
Footcandles On Wall
3' from Wall 4' On Center
1 46.6 28.6 46.6
2 60.9 43.0 60.9
3 58.6 44.3 58.6
4 51.9 44.8 51.9
5 49.3 42.1 49.3
6 42.6 39.5 42.6
7 36.0 36.4 36.0
8 31.6 32.5 31.6
9 28.4 28.7 28.4 10 25.8 25.6 25.8 11 23.6 23.2 23.6 12 21.7 21.3 21.7 13 20.4 20.1 20.4 14 19.6 19.3 19.6
30°
60°
Downlight Side
Wall Wash
Side
Distance From Ceiling in Feet
4'
Multiple Units -
Footcandles On Wall
4' from Wall - 4' On Center
1 25.8 22.6 25.8 2 37.5 35.2 37.5 3 43.4 39.7 43.4 4 41.4 39.8 41.4 5 38.9 37.1 38.9 6 38.4 34.9 38.4 7 36.5 33.9 36.5 8 33.5 32.3 33.5
9 30.7 30.0 30.7 10 28.3 27.7 28.3 11 26.2 25.6 26.2 12 24.4 23.8 24.4 13 22.8 22.4 22.8 14 21.6 21.2 21.6
Distance From Ceiling in Feet
4'
Multiple Units -
Footcandles On Wall
4' from Wall - 5' On Center
1 24.0 16.7 24.0 2 33.5 26.5 33.5 3 38.4 30.1 38.3 4 36.5 30.3 36.5 5 33.3 30.1 33.3 6 32.5 28.8 32.5 7 31.2 27.6 31.1 8 28.1 26.6 28.1
9 25.3 25.3 25.3 10 23.2 23.5 23.2 11 21.7 21.8 21.7 12 20.4 20.2 20.4 13 19.3 18.9 19.3 14 18.4 17.9 18.4
Distance From Ceiling in Feet
5'
150W ED17 PHILIPS COATED CERAMIC MH, 3K. LUMEN RATING = 11900 LMS., AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM, REPORT NO. 2365FR
Multiple Units -
Footcandles On Wall
3' from Wall 4' On Center
1 47.4 38.1 47.4 2 68.3 57.9 68.3 3 74.4 64.1 74.4 4 71.4 69.7 71.4 5 71.3 68.2 71.3 6 63.3 65.2 63.3 7 55.4 59.4 55.3 8 49.6 52.4 49.6
9 44.9 45.9 44.9 10 40.6 40.5 40.6 11 37.0 36.5 37.0 12 33.9 33.4 33.9 13 31.8 31.3 31.7 14 30.5 30.1 30.5
30°
60°
Downlight Side
Wall Wash
Side
Distance From Ceiling in Feet
4'
Multiple Units -
Footcandles On Wall
4' from Wall - 4' On Center
1 30.7 28.7 30.7 2 44.7 41.6 44.6 3 52.7 50.5 52.7 4 54.6 55.5 54.6 5 54.9 56.5 54.9 6 55.6 56.9 55.6 7 53.7 56.6 53.7 8 50.5 53.2 50.5
9 47.3 48.8 47.3 10 44.2 44.7 44.2 11 41.2 41.1 41.2 12 38.3 38.1 38.3 13 35.9 35.8 35.8 14 34.0 34.0 34.0
Distance From Ceiling in Feet
4'
Multiple Units -
Footcandles On Wall
4' from Wall - 5' On Center
1 26.8 23.7 26.8 2 38.3 33.5 38.3 3 44.7 40.3 44.7 4 47.1 43.1 47.1 5 45.7 45.8 45.7 6 46.5 45.6 46.5 7 45.3 45.2 45.3 8 41.7 43.7 41.7
9 38.5 41.0 38.5 10 36.0 37.9 36.0 11 34.0 34.8 34.0 12 32.0 32.1 32.0 13 30.2 29.9 30.2 14 28.9 28.3 28.9
Distance From Ceiling in Feet
5'
Lighting Data - Example
C7E170W illumination on the wall 6' down
from the ceiling is 28.0 f.c. beneath and
27.7 f.c. between fixtures.
1,375
2,750
4,125
5,500
3,125
2,750
6,375
8,500
Lighting data above is certified, computed by LSI Program **TEST-LITE**
Multiple Units -
Footcandles On Wall
3' from Wall - 4' On Center
1 34.7 19.9 34.7 2 43.5 31.3 43.4 3 40.3 32.2 40.3 4 34.5 32.0 34.5 5 31.4 30.2 31.4 6 28.0 27.7 28.0 7 24.3 25.2 24.2 8 21.4 22.4 21.4
9 19.1 19.8 19.1 10 17.3 17.6 17.3 11 15.8 15.9 15.8 12 14.6 14.5 14.6 13 13.8 13.6 13.7 14 13.2 13.0 13.2
Distance From Ceiling in Feet
4'
Multiple Units -
Footcandles On Wall
4' from Wall - 4' On Center
1 19.2 16.5 19.2 2 26.9 25.9 26.9 3 30.9 29.0 30.9 4 28.7 29.2 28.7 5 26.2 27.1 26.2 6 25.1 25.3 25.1 7 23.9 24.3 23.9 8 22.2 22.8 22.2
9 20.6 21.1 20.5 10 19.0 19.3 19.0 11 17.7 17.8 17.7 12 16.5 16.4 16.5 13 15.5 15.3 15.4 14 14.6 14.5 14.6
Distance From Ceiling in Feet
4'
3'
28.0 f.c.
27.7 f.c.
28.0 f.c.
4'
6'
Loading...