Lightolier C7E170HW User Manual

8
1
5
3
9 7
2
6 4
8
Vertical Adjustment: 5/8" (16 mm) to 2 7/8" (73 mm)
2" (50 mm) max. Ceiling Thickness
7-3/8" (187 mm) Dia.
8-1/2"
(216 mm)
(276 mm
8-5/8" (200 mm) Dia.
10-1/2"
(267 mm)
10-7/8"
(276 mm)
18-5/8" (473 mm)
Top View
(Magnetic Ballast)
8-1/4"
(210 mm)
20" (508 mm) to 30" (762 mm)
9-3/4" (248 mm)
10-7/8"
(276 mm)
11-1/2"
(292 mm)
Top View
(Electronic Ballast)
9-3/4" (248 mm)
20" (508 mm) to 30" (762 mm)
11" (280 mm)
(100/150W)
Calculite
®
HID Downlight C7E170HW
Page 1 of 2 7" Aperture, ED17 (Open Rated), Ceramic Metal Halide, Wide Beam
Ceiling Cutout: 8" (203 mm) Dia.
Reflector Trim Frame-In Kit Lamp (Coated, Ceramic MH)
C7E17OHW CLW Specular Clear, White Painted Flange. C770MHOE1 Electronic 120V C770MHOE2 Electronic 277V 70W E17, ED17, BD17, (Open Rated)
CLP Specular Clear, Matching Flange. C710MHOE1 Electronic 120V C710MHOE2 Electronic 277V 100W E17, ED17, BD17, (Open Rated) CCDW Comfort Clear Diffuse, White Painted Flange. C715MHOE1 Electronic 120V C715MHOE2 Electronic 277V 150W E17, ED17, BD17, (Open Rated) CCDP Comfort Clear Diffuse, Matching Flange. C770MHOU Magnetic 120V/277V 70W E17, ED17, BD17, (Open Rated) CCZW Champagne Bronze, White Painted Flange. C710MHOU Magnetic 120V/277V 100W E17, ED17, BD17, (Open Rated) CCZP Champagne Bronze, Matching Flange. C715MHOU Magnetic 120V/277V 150W E17, ED17, BD17, Open Rated)
Features
1. Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides wide
beam distribution. Provides 50° visual cut-off to lamp and lamp image; self-flange in painted white or aperture-matching polished flange. Consult factory for other finishes.
2. Socket Housing: Galvanized steel, pre-wired with medium base pulse rated
socket. Snaps onto upper reflector for secure attachment without tools; unitized construction assures proper lamp alignment to optics for consistent performance.
3. Mounting Frame: 0.048" (18-ga.) galvanized steel includes pre-installed
mounting bars.
4. Mounting Ring: 0.048" (18-ga.) galvanized steel. Designed for vertical
adjustment from above or below for ceilings from 0" to 2" thick. Center-line notches allow consistent alignment of multiple fixtures.
5. Retention Springs: Rust resistant springs secure cone in place for quick,
tool-less installation.
6. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism
accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation.
7. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to
30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories.
8. Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V).
Accessible from below for inspection and/or replacement without tools.
9. Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90°C through branch circuit conductors; allows inspection from below.
10. Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not
install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high-power factor, T.H.D.
<15%, thermally and transient protected, RMI / RFI complies with FCC Part 18 non-consumer equipment, shut-down circuit at end of lamp life, sound rating "A",
-50°F minimum starting temperature, Type 1 outdoor rating.
Electrical (cont.)
Ballast ANSI Code Voltage Max. Amps Input Watts
70W MH M98/M139 120/277 0.67/0.29 78 100W MH M90/M140 120/277 0.90/0.43 110 150W MH M102 120/277 1.40/0.61 167
Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, HX-HPF
circuit type, high power factor, sound rating "B", -20°F minimum starting temperature, Type 1 Outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts
70W MH M98/M143 120/277 1.90/0.80 94 100W MH M90/M140 120/277 2.40/1.10 125 150W MH M102 120/277 3.70/1.60 180
Options and Accessories
Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. c ”A“. Emergency Lamp: Add suffix E to Reflector Trim and Frame-In Kit.
See Spec. Sheet “A/E”.
Slope Ceiling Adapters: See Specification Sheet SCA. Chicago Plenum: Consult Factory. Fuse: (Magnetic Ballast): Add suffix F1 or F2 to Frame in Kit (F1=120V, F2=277V).
Labels
UL (Suitable for Damp Locations), CSA, I.B.E.W. For 150W, install fixtures with minimum spacing: 3 feet from center-to-center of adjacent luminaries; 3 inch from top of luminaire to overhead building member;1 1/2 feet from luminaire center to side building member.
Job Information Type:
Job Name: Cat. No.:
Lamp(s): Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504
Calculite
®
HID Downlight C7E170HW
Page 2 of 2 7" Aperture, ED17 (Open Rated), Ceramic Metal Halide, Wide Beam
70W ED17 (ENCLOSED) PHILIPS COATED METAL HALIDE LAMP. LUMEN RATING = 5700 LMS., AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM
ANGLE 0° 45° 90° 0 2517 2517 2517 5 2462 2535 2572 10 2242 2537 2678 15 2201 2705 2823
750
20 2230 2610 2778 25 2233 2365 2464
60°
30 1916 2096 2180 35 1322 1698 1886
1,500
40 823 1127 1271 45 234 349 480 50 20 20 51 55 5 8 8 60 2 3 3
2,250
65 0 1 1 70 0 1 0 75 0 0 0 80 0 0 0 85 0 0 0
3,000
** EFFICIENCY = 60.1% ** CERTIFIED TEST REPORT NO. 2418FR, DATE: FEB 10, 2004
SC = 1.1 COMPUTED BY LSI PROGRAM **TEST-LITE**
90 0 0 0
30°
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE 0 Deg. 45 Deg. 90 Deg.
45 11611 17393 23922 55 306 466 466 65 0 71 57 75 0 23 0 85 0 0 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 2050 35.98 59.89 0-40 3062 53.73 89.44 0-60 3423 60.05 99.96
0-90 3424 60.08 100 40-90 361 6.34 10.56 60-90 1 0.02 0.04
90-180 0 0 0
0-180 3424 60.08 100
CEILING 80% 70% 50% 30%
Coefficients of Utilization
WALL 70 50 30 10 50 10 50 10 50 10 0
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .72 .72 .72 .72 .70 .70 .67 .67 .64 .64 .60 1 .68 .67 .66 .64 .66 .63 .63 .61 .61 .59 .57 2 .65 .63 .61 .59 .62 .58 .60 .57 .58 .56 .54 3 .62 .59 .56 .54 .58 .54 .57 .53 .55 .52 .50 4 .60 .56 .52 .50 .55 .50 .54 .49 .52 .49 .47 5 .57 .52 .49 .46 .51 .46 .50 .46 .49 .45 .44 6 .54 .49 .46 .43 .48 .43 .48 .43 .47 .42 .41 7 .51 .46 .42 .40 .45 .40 .45 .40 .44 .39 .38 8 .48 .43 .39 .37 .42 .37 .42 .37 .41 .36 .36 9 .46 .40 .36 .34 .40 .34 .39 .34 .39 .34 .33 10 .43 .37 .34 .31 .37 .31 .36 .31 .36 .31 .30
LUMINAIRE INPUT WATTS = 78.0
100W ED17 (ENCLOSED) PHILIPS COATED METAL HALIDE LAMP. LUMEN RATING = 8500 LMS., AROMAT, ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM
ANGLE 0° 45° 90° 0 4622 4622 4622 5 4767 4575 4529 10 4783 4421 4539 15 4151 4423 4544
1,250
20 3703 4033 4286 25 3387 3501 3570
60°
30 3033 3024 3064 35 2201 2273 2443
2,500
40 1410 1566 1617 45 501 615 580 50 63 56 62 55 19 19 18 60 10 12 9
3,750
45°
65 5 7 5 70 3 3 2 75 1 1 0 80 0 0 0 85 0 0 0
5,000
** EFFICIENCY = 62.2% ** CERTIFIED TEST REPORT NO. 2267FR , DATE: JUN 23, 2003
SC = 1.1 COMPUTED BY LSI PROGRAM **TEST-LITE**
90 0 0 0
30°
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE 0 Deg. 45 Deg. 90 Deg.
45 24858 30607 28891 55 1140 1179 1075 65 422 611 376 75 153 153 0 85 0 0 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 3282 38.62 62.14
0-40 4720 55.54 89.35
0-60 5275 62.07 99.86
0-90 5283 62.15 100 40-90 562 6.62 10.65 60-90 7 0.08 0.14
90-180 0 0 0
0-180 5283 62.15 100
CEILING 80% 70% 50% 30%
Coefficients of Utilization
WALL 70 50 30 10 50 10 50 10 50 10 0
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .74 .74 .74 .74 .72 .72 .69 .69 .66 .66 .62 1 .71 .69 .68 .67 .68 .66 .65 .64 .63 .62 .59 2 .68 .65 .63 .61 .64 .60 .62 .59 .60 .58 .56 3 .65 .61 .58 .56 .60 .56 .59 .55 .57 .54 .52 4 .62 .58 .55 .52 .57 .52 .56 .51 .55 .51 .49 5 .59 .54 .51 .48 .54 .48 .53 .48 .52 .47 .46 6 .56 .51 .48 .45 .51 .45 .50 .45 .49 .45 .43 7 .53 .48 .45 .42 .48 .42 .47 .42 .46 .41 .40 8 .51 .45 .42 .39 .45 .39 .44 .39 .43 .39 .38 9 .48 .42 .39 .36 .42 .36 .41 .36 .41 .36 .35 10 .45 .40 .36 .34 .39 .34 .39 .33 .38 .33 .32
LUMINAIRE INPUT WATTS = 110
Job Information Type:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504