Calculite
®
HID Downlight C6T6VW
Page 1 of 2 6" Aperture, 2pc Vertical, T6 Wide Beam
Top View: Magnetic Ballast
Top View: Electronic Ballast
Ceiling Cutout: 6 9/16” (167 mm) Dia.
Reflector Trim Frame-In Kit Lamp
C6T6VW
CLP Specular Clear, Matching Flange.
CCDW Comfort Clear Diffuse, White Painted Flange.
CCDP Comfort Clear Diffuse, Matching Flange.
CCZW Champagne Bronze, White Painted Flange.
CCZP Champagne Bronze, Matching Flange.
CLW Specular Clear, White Painted Flange.
C639T6E1 Electronic 120V 39W T6 Ceramic Metal Halide
C639T6E2 Electronic 277V 39W T6 Ceramic Metal Halide
C670T6E1 Electronic 120V 70W T6 Ceramic Metal Halide
C670T6E2 Electronic 277V 70W T6 Ceramic Metal Halide
C615T6E1 Electronic 120V 150W T6 Ceramic Metal Halide
C615T6E2 Electronic 277V 150W T6 Ceramic Metal Halide
C615T6U Magnetic 120V/277V 150W T6 Ceramic Metal Halide
Features
1. Upper Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides wide
beam optics ideal for general lighting. Also available in narrow and medium
beam, see C6T6VN and C6T6VM specification sheets.
2. Aper ture Cone: Provides 50° visual cut-off to lamp and lamp image; self-
flange in painted white or aperture-matching polished flange. Consult factory
for other finishes.
3. Lamp Shield: High-temperature glass as required by code, captive during
re-lamping. Light diffusion provides exceptionally smooth beam.
4. Socket Housing: Galvanized steel, pre-wired with G12 pulse rated socket.
Snaps onto upper reflector for secure attachment without tools; assures
proper lamp alignment to optics for consistent performance..
5. Mounting Frame: 0.048" (18-ga.) galvanized steel. Ver tical adjustment
mechanism accommodates mounting to virtually any ceiling system using
mounting bars (provided, or 1/2" EMT tubing (by others). Single locking
feature secures all adjustments. Alignment holes and markings allow fixture
to be preset prior to installation.
6. Mounting Ring: 0.048"(18-ga.) galvanized steel. Designed for vertical
adjustment from above or below for ceilings from 0" to 2" thick. Center-line
notches allow consistent alignment of multiple fixtures.
7. Mounting Bars: 0.048" (18-ga.) pre-installed, telescoping bars extend to
30" long and lock securely into position. Built-in locking tabs provide positive
attachment to common T-bar systems. Self-centering feature simplifies
installation in 24" O.C. grid systems. Attaches to steel or wood joists without
accessories.
8. Trim Retention Springs: Rust resistant springs secure reflector/housing for
quick, tool-less installation.
9. Ballast / Socket Housing / Cover Assembly: Snaps onto junction box
without tools for inspection and ballast replacement, accessible from below.
10. Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90°C through branch circuit conductors. Allows inspection from below.
11. Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not
install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical (cont.)
150W Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted,
HX-HPF circuit type, high power factor, sound rating “B”, -20°F minimum star ting
temperature, Type 1 Outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts
39W MH M130 120/277 0.39/0.17 44
70W MH M139 120/277 0.67/0.29 78
150W MH M142 120/277 1.40/0.60 169/166
* 150W MH M142 120/277 3.70/1.60 180
* Magnetic Ballast
Options and Accessories
Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. See Spec.Sheet
”A/E“. For 277 electronic consult factory.
Emergency: Add suffix E to Reflector Trim and Frame-In Kit. See Spec.
Sheet“A/E”.
Slope Ceiling Adapters: See Specification Sheet SCA.
Chicago Plenum: Consult Factory.
Labels
cULus (Suitable for Damp Locations), I.B.E.W. For 150W, install fixtures with
minimum spacing; 3 feet from center-to center of adjacent luminaries, 3” from
top of luminaire to overhead building member; 1 1/2 feet from luminaire center to
side building member.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Electrical
Electronic Ballast: 120 or 277V, 50/60 Hz., encased, high power factor, T.H.D.
<15%, thermally and transient protected, RMI/RFI complies with FCC Part 18
non-consumer equipment, shut-down circuit at end of lamp life, sound rating “A”,
-5°F (-20°F for 150W) minimum starting temperature, Type 1 outdoor rating.
Lightolier is a Philips group brand
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • B1204
Calculite
®
HID Downlight C6T6VW
Page 2 of 2 6" Aperture, 2pc Vertical, T6 Wide Beam
39W T6 PHILIPS CMH LAMP, LUMEN RATING = 3400 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH TRIM
CANDLEPOWER DISTRIBUTION
375
750
1,125
1,500
** EFFICIENCY = 63.7% ** CERTIFIED TEST REPORT NO. 2327FR, DATE: OCT 25, 2003
SC = 1.2 COMPUTED BY LSI PROGRAM **TEST-LITE**
1,125
70W T6 PHILIPS CMH LAMP, LUMEN RATING = 6600 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH TRIM
CANDLEPOWER DISTRIBUTION
625
1,250
1,875
2,500
** EFFICIENCY = 60.5% ** CERTIFIED TEST REPORT NO. 2323FR, DATE: OCT 04, 2003
SC = 1.2 COMPUTED BY LSI PROGRAM **TEST-LITE**
ANGLE MEAN CP LUMENS
0 1448
5 1453 139
10 1489
15 1502 420
20 1431
25 1349 638
60°
30 1390
35 1157 695
40 726
45 308 264
50 24
55 3 7
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
30°
ANGLE MEAN CP LUMENS
0 2579
5 2582 248
10 2633
15 2667 747
20 2575
25 2503 1177
60°
30 2594
35 2181 1309
40 1382
45 564 495
50 45
55 8 14
60 2
65 0 1
70 0
75 0 0
80 0
85 0 0
90 0
30°
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 26087
55 338
65 0
75 0
85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 1197 35.22 55.34
0-40 1893 55.68 87.47
0-60 2164 63.65 100
0-90 2164 63.65 100
40-90 271 7.97 12.53
60-90 0 0 0
90-180 0 0 0
0-180 2164 63.65 100
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 47753
55 792
65 11
75 0
85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 2172 32.91 54.43
0-40 3481 52.75 87.24
0-60 3990 60.46 99.98
0-90 3990 60.47 100
40-90 509 7.72 12.76
60-90 0 0.01 0.02
90-180 0 0 0
0-180 3990 60.47 100
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
Coefficients of Utilization
RCR
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
0 .76 .76 .76 .76 .74 .74 .71 .71 .68 .68 .64
1 .73 .71 .70 .68 .70 .67 .67 .65 .65 .63 .60
2 .70 .67 .64 .62 .66 .62 .63 .60 .62 .59 .57
3 .66 .62 .59 .57 .61 .56 .60 .56 .58 .55 .53
4 .63 .58 .55 .53 .58 .52 .56 .52 .55 .51 .49
5 .60 .55 .51 .48 .54 .48 .53 .48 .52 .47 .46
6 .57 .51 .47 .45 .51 .44 .50 .44 .49 .44 .43
7 .53 .48 .44 .41 .47 .41 .46 .41 .45 .40 .39
8 .50 .44 .40 .38 .44 .37 .43 .37 .42 .37 .36
9 .47 .41 .37 .34 .41 .34 .40 .34 .39 .34 .33
10 .44 .38 .34 .31 .38 .31 .37 .31 .37 .31 .30
LUMINAIRE INPUT WATTS = 44
Coefficients of Utilization
RCR
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
0 .72 .72 .72 .72 .71 .71 .67 .67 .65 .65 .61
1 .69 .67 .66 .65 .66 .64 .64 .62 .61 .60 .57
2 .66 .63 .61 .59 .62 .58 .60 .57 .58 .56 .54
3 .63 .59 .56 .54 .58 .53 .57 .53 .55 .52 .50
4 .60 .55 .52 .50 .55 .49 .53 .49 .52 .48 .47
5 .56 .52 .48 .45 .51 .45 .50 .45 .49 .44 .43
6 .54 .48 .45 .42 .48 .42 .47 .42 .46 .41 .40
7 .50 .45 .41 .39 .44 .38 .44 .38 .43 .38 .37
8 .48 .42 .38 .35 .41 .35 .41 .35 .40 .35 .34
9 .45 .39 .35 .32 .38 .32 .38 .32 .37 .32 .31
10 .42 .36 .32 .29 .35 .29 .35 .29 .34 .29 .28
LUMINAIRE INPUT WATTS = 78
150W T6 PHILIPS CMH LAMP, LUMEN RATING = 14000 LMS, AROMAT ELECTRONIC BALLAST , CL FINISH TRIM
CANDLEPOWER DISTRIBUTION
ANGLE MEAN CP LUMENS
0 5583
1,375
3,750
4,125
5,500
** EFFICIENCY = 60.2% * CERTIFIED TEST REPORT NO. 2330FR, DATE: OCT 07, 2003
SC = 1.25 COMPUTED BY LSI PROGRAM **TEST-LITE**
5 5573 533
10 5619
15 5646 1588
20 5503
60°
25 5245 2472
30 5370
35 4530 2727
40 2936
45 1247 1071
50 102
55 17 32
60 7
65 1 2
70 0
75 0 0
80 0
85 0 0
30°
90 0
Lightolier is a Philips group brand
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 105687
55 1783
65 209
75 0
85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 4593 32.81 54.51
0-40 7321 52.29 86.88
0-60 8424 60.17 99.97
0-90 8426 60.19 100
40-90 1105 7.9 13.12
60-90 2 0.02 0.03
90-180 0 0 0
0-180 8426 60.19 100
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • B1204
Coefficients of Utilization
RCR
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
0 .72 .72 .72 .72 .70 .70 .67 .67 .64 .64 .60
1 .69 .67 .66 .64 .66 .63 .63 .61 .61 .59 .57
2 .65 .63 .61 .58 .62 .58 .60 .57 .58 .55 .53
3 .62 .58 .56 .53 .58 .53 .56 .52 .55 .51 .50
4 .59 .55 .52 .49 .54 .49 .53 .48 .52 .48 .46
5 .56 .51 .48 .45 .51 .45 .50 .45 .49 .44 .43
6 .53 .48 .44 .42 .47 .42 .47 .41 .46 .41 .40
7 .50 .45 .41 .38 .44 .38 .43 .38 .43 .38 .37
8 .47 .41 .38 .35 .41 .35 .40 .35 .40 .35 .34
9 .44 .38 .35 .32 .38 .32 .37 .32 .37 .32 .31
10 .42 .35 .32 .29 .35 .29 .35 .29 .34 .29 .28
LUMINAIRE INPUT WATTS = 167