Top View: Magnetic Ballast
Top View: Electronic Ballast Ceiling Cutout: 6 9/16” (167 mm) Dia.
Reflector Trim Frame-In Kit Lamp
C6T6VN CLW Specular Clear, White Painted Flange. CLP Specular Clear, Matching Flange. CCDW Comfort Clear Diffuse, White Painted Flange. CCDP Comfort Clear Diffuse, Matching Flange. CCZW Champagne Bronze, White Painted Flange. CCZP Champagne Bronze, Matching Flange.
C639T6E1 Electronic 120V 39W T6 Ceramic Metal Halide C639T6E2 Electronic 277V 39W T6 Ceramic Metal Halide C670T6E1 Electronic 120V 70W T6 Ceramic Metal Halide C670T6E2 Electronic 277V 70W T6 Ceramic Metal Halide C615T6E1 Electronic 120V 150W T6 Ceramic Metal Halide C615T6E2 Electronic 277V 150W T6 Ceramic Metal Halide C615T6U Magnetic 120V/277V 150W T6 Ceramic Metal Halide
Features
1. Upper Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides narrow
beam optics ideal for high ceilings. Also available in medium and wide beam, see C4T4VM and C4T4VW specification sheets.
2. Aper ture Cone: Provides 50° visual cut-off to lamp and lamp image; self-
flange in painted white or aperture-matching polished flange. Consult factory
for other finishes.
3. Lamp Shield: High-temperature glass as required by code, captive during
re-lamping. Light diffusion provides exceptionally smooth beam.
4. Socket Housing: Galvanized steel, pre-wired with G12 pulse rated socket.
Snaps onto upper reflector for secure attachment without tools; assures
proper lamp alignment to optics for consistent performance.
5. Mounting Frame: 0.048" (18-ga.) galvanized steel. Ver tical adjustment
mechanism accommodates mounting to virtually any ceiling system using mounting bars (provided, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture
to be preset prior to installation.
6. Mounting Ring: 0.048"(18-ga.) galvanized steel. Designed for vertical
adjustment from above or below for ceilings from 0" to 2" thick. Center-line notches allow consistent alignment of multiple fixtures.
7. Mounting Bars: 0.048" (18-ga.) pre-installed, telescoping bars extend to
30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without
accessories.
8. Trim Retention Springs: Rust resistant springs secure reflector/housing for
quick, tool-less installation.
9. Ballast / Socket Housing / Cover Assembly: Snaps onto junction box
without tools for inspection and ballast replacement, accessible from below.
10. Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90°C through branch circuit conductors. Allows inspection from below.
11. Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not
install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical (cont.)
150W Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted,
HX-HPF circuit type, high power factor, sound rating “B”, -20°F minimum star ting temperature, Type 1 Outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts
39W MH M130 120/277 0.39/0.17 44 70W MH M139 120/277 0.67/0.29 78 150W MH M142 120/277 1.40/0.60 169/166 *150W MH M142 120/277 3.70/1.60 180 *Magnetic Ballast
Options and Accessories
Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. See Spec.Sheet
”A/E“. For 277 electronic consult factory Emergency: Add suffix E to Reflector Trim and Frame-In Kit. See Spec. Sheet “A/E”.
Slope Ceiling Adapters: See Specification Sheet SCA. Chicago Plenum: Consult Factory.
Labels
cULus (Suitable for Damp Locations), I.B.E.W. For 150W, install fixtures with minimum spacing; 3 feet from center-to center of adjacent luminaries, 3” from top of luminaire to overhead building member; 1 1/2 feet from luminaire center to side building member.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s): Notes:
Electrical
Electronic Ballast: 120 or 277V, 50/60 Hz., encased, high power factor, T.H.D.
<15%, thermally and transient protected, RMI/RFI complies with FCC Part 18 non-consumer equipment, shut-down circuit at end of lamp life, sound rating “A”,
-5°F (-20°F for 150W) minimum starting temperature, Type 1 outdoor rating.
Lightolier is a Philips group brand
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • B1204
Calculite
®
HID Downlight C6T6VN
Page 2 of 2 6" Aperture, 2pc Vertical, T6 Narrow Beam
39W T6 PHILIPS METAL HALIDE LAMP. LUMEN RATING = 3400 LMS. AROMAT ELECTRONIC BALLAST, CL Finish
CANDLEPOWER DISTRIBUTION
1,000
2,000
3,000
4,000
** EFFICIENCY = 64.0% ** CERTIFIED TEST REPORT NO. 2336FR, DATE: OCT 24, 2003 SC = 0.6 COMPUTED BY LSI PROGRAM **TEST-LITE**
70W T6 PHILIPS METAL HALIDE LAMP. LUMEN RATING = 6600 LMS. AROMAT ELECTRONIC BALLAST, CL Finish
CANDLEPOWER DISTRIBUTION
1,750
3,500
5,250
7,000
** EFFICIENCY = 62.9% ** CERTIFIED TEST REPORT NO. 2334FR, DATE: OCT 14, 2003 SC = 0.6 COMPUTED BY LSI PROGRAM **TEST-LITE**
ANGLE MEAN CP LUMENS
0 3984 5 3765 352 10 3218 15 2533 716 20 1816 25 1212 583
60°
30 795 35 570 368 40 407 45 189 155 50 14 55 2 4 60 0 65 0 0 70 0 75 1 1 80 0 85 0 0 90 0
30°
ANGLE MEAN CP LUMENS
0 7054 5 6730 630 10 5887 15 4740 1334 20 3463 25 2357 1129
60°
30 1584 35 1148 737 40 812 45 377 310 50 33 55 7 11 60 4 65 2 2 70 0 75 0 0 80 0 85 0 0 90 0
30°
LUMINANCE SUMMARY
ANGLE MEAN CD/SQ M 45 16034 55 175 65 0 75 162 85 0
ZONE LUMENS % LAMP %LUMINAIRE 0-30 1650 48.53 75.77 0-40 2017 59.35 92.67 0-60 2176 64.02 99.96 0-90 2177 64.05 100.00 40-90 159 4.70 7.33 60-90 0 .02 .04 90-180 0 .00 .00 0-180 2177 64.05 100.00
ANGLE MEAN CD/SQ M 45 31949 55 688 65 350 75 0 85 0
ZONE LUMENS % LAMP %LUMINAIRE 0-30 3093 46.88 74.48 0-40 3830 58.04 92.22 0-60 4151 62.91 99.95 0-90 4153 62.94 100.00 40-90 323 4.89 7.78 60-90 2 .03 .05 90-180 0 .00 .00 0-180 4153 62.94 100.00
CD. / SQ. M.
ZONAL LUMENS AND PERCENTAGES
LUMINANCE SUMMARY
CD. / SQ. M.
ZONAL LUMENS AND PERCENTAGES
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .76 .76 .76 .76 .74 .74 .71 .71 .68 .68 .64 1 .73 .72 .71 .70 .71 .68 .68 .66 .66 .64 .61 2 .71 .68 .66 .65 .67 .64 .65 .63 .63 .61 .59 3 .68 .65 .63 .61 .64 .60 .63 .59 .61 .58 .57 4 .66 .62 .59 .57 .61 .57 .60 .56 .59 .56 .54 5 .63 .59 .56 .54 .59 .54 .57 .53 .57 .53 .52 6 .61 .57 .54 .52 .56 .51 .55 .51 .55 .51 .50 7 .59 .54 .51 .49 .54 .49 .53 .49 .52 .48 .47 8 .57 .52 .49 .47 .51 .46 .51 .46 .50 .46 .45 9 .54 .49 .46 .44 .49 .44 .48 .44 .48 .44 .43 10 .52 .47 .44 .42 .47 .42 .46 .42 .46 .42 .41
LUMINAIRE INPUT WATTS = 44
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .75 .75 .75 .75 .73 .73 .70 .70 .67 .67 .63 1 .72 .71 .69 .68 .70 .67 .67 .65 .64 .63 .60 2 .69 .67 .65 .63 .66 .63 .64 .61 .62 .60 .58 3 .67 .64 .61 .59 .63 .59 .61 .58 .60 .57 .55 4 .64 .61 .58 .56 .60 .56 .59 .55 .58 .54 .53 5 .62 .58 .55 .53 .57 .52 .56 .52 .55 .52 .50 6 .60 .55 .52 .50 .55 .50 .54 .50 .53 .49 .48 7 .57 .53 .50 .48 .52 .47 .51 .47 .51 .47 .46 8 .55 .50 .47 .45 .50 .45 .49 .45 .49 .45 .44 9 .53 .48 .45 .43 .47 .43 .47 .42 .46 .42 .41 10 .51 .46 .43 .40 .45 .40 .45 .40 .44 .40 .39
LUMINAIRE INPUT WATTS = 78
150W T6 PHILIPS METAL HALIDE LAMP. LUMEN RATING = 14000 LMS. AROMAT ELECTRONIC BALLAST, CL Finish
CANDLEPOWER DISTRIBUTION
ANGLE MEAN CP LUMENS
0 13758 5 13134 1232
3,750
7,500
11,250
15,000
** EFFICIENCY = 61.2% ** CERTIFIED TEST REPORT NO. 2333FR, DATE: OCT 13, 2003 SC = 0.7 COMPUTED BY LSI PROGRAM **TEST-LITE**
10 11593 15 9424 2655 20 7028 25 4935 2359
60°
30 3491 35 2551 1627 40 1766 45 816 671 50 70 55 12 22 60 4 65 7 5 70 3 75 1 2 80 0 85 0 0 90 0
30°
Lightolier is a Philips group brand
LUMINANCE SUMMARY
ANGLE MEAN CD/SQ M 45 69119 55 1223 65 1001 75 344 85 0
ZONE LUMENS % LAMP %LUMINAIRE 0-30 6246 44.62 72.86 0-40 7873 56.24 91.83 0-60 8566 61.19 99.92 0-90 8573 61.24 100.00 40-90 700 5.00 8.17 60-90 6 .05 .08 90-180 0 .00 .00 0-180 8573 61.24 100.00
CD. / SQ. M.
ZONAL LUMENS AND PERCENTAGES
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • B1204
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .73 .73 .73 .73 .71 .71 .68 .68 .65 .65 .61 1 .70 .69 .67 .66 .68 .65 .65 .63 .63 .61 .59 2 .67 .65 .63 .61 .64 .61 .62 .59 .60 .58 .56 3 .65 .62 .59 .57 .61 .57 .59 .56 .58 .55 .54 4 .62 .59 .56 .54 .58 .54 .57 .53 .56 .53 .51 5 .60 .56 .53 .51 .55 .51 .54 .50 .53 .50 .49 6 .58 .53 .50 .48 .53 .48 .52 .48 .51 .47 .46 7 .55 .51 .48 .46 .50 .45 .50 .45 .49 .45 .44 8 .53 .48 .45 .43 .48 .43 .47 .43 .47 .43 .42 9 .51 .46 .43 .41 .46 .41 .45 .41 .45 .40 .40 10 .49 .44 .41 .39 .43 .39 .43 .38 .43 .38 .38
LUMINAIRE INPUT WATTS = 167