Calculite
5 7/8" (149 mm) Dia.
4
7
3
8105 692
9
1
5 5/8" (143 mm) Dia.
Vertical Adjustment:
5/8" (16 mm) to
2 7/8" (73 mm)
2" (50 mm) max.
Ceiling Thickness
11-1/4"
(286 mm)
7-1/4" (184 mm) Dia.
18-5/8" (473 mm)
20" (508 mm) to 30" (762 mm)
10-7/8"
(276 mm)
9-3/4"
(248 mm)
10-1/2"
(267 mm)
Top View
(Magnetic Ballast)
7-1/4"
(184 mm)
11" (280 mm)
(100W)
10-7/8"
(276 mm)
Top View
(Electronic Ballast)
9-3/4"
(248 mm)
20" (508 mm) to
30" (762 mm)
®
HID Downlight C6P38MH
Page 1 of 2 6" Aperture, PAR38 Ceramic MH
Ceiling Cutout: 6 9/16”(167 mm) Dia.
Reflector Trim Frame-In Kit Lamp
C6P38MH CLW Specular Clear, White Painted Flange.
CLP Specular Clear, Matching Flange.
CCDW Comfort Clear Diffuse, White Painted Flange.
CCDP Comfort Clear Diffuse, Matching Flange.
CCZW Champagne Bronze, White Painted Flange.
CCZP Champagne Bronze, Matching Flange.
MG Black Multi-Groove, White Molded Trim Ring.
C670MHE1 Electronic 120V 70W PAR38 Ceramic Metal Halide
C670MHE2 Electronic 277V 70W PAR38 Ceramic Metal Halide
C610MHE1 Electronic 120V 100W PAR38 Ceramic Metal Halide
C610MHE2 Electronic 277V 100W PAR38 Ceramic Metal Halide
C670MHU Magnetic 120V/277V 70W PAR38 Ceramic Metal Halide
C610MHU Magnetic 120V/277V 100W PAR38 Ceramic Metal Halide
.
Features
1. Reflector Trim: Clear anodized aluminum, 0.040” (16-ga.). Provides 45°
visual cut-off to lamp and lamp image; self-flange in painted white or
aperture-matching polished flange. Consult factory for other finishes.
2. Mulit-Groove Baffle: One piece seamless aluminum. Sharply detailed con-
centric rings, black finish. Permanently fastened to specular clear reflector.
3. Socket Cup: Galvanized steel, pre-wired with medium base pulse rated
socket. Snaps onto upper reflector for secure attachment without tools;
assures proper lamp alignment to optics for consistent performance.
4. Mounting Frame: 0.048" (18-ga.) galvanized steel includes pre-installed
mounting bars.
5. Mounting Ring: 0.048" (18-ga.) galvanized steel. Designed for vertical
adjustment from above or below for ceilings from 0" to 2" thick. Center-line
notches allow consistent alignment of multiple fixtures.
6. Retention Springs: Rust resistant springs secure cone in place for quick,
tool-less installation.
7. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism
accommodates mounting to virtually any ceiling system using pre-installed
mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures
all adjustments. Alignment holes and markings allow fixture to be pre-set
prior to installation.
8. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to 30"
long and lock securely into position. Built-in locking tabs provide positive
attachment to common T-bar systems. Self-centering feature simplifies
installation in 24" O.C. grid systems. Attaches to steel or wood joists without
accessories.
9. Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V).
Accessible from below for inspection and/or replacement without tools.
10. Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90°C through branch circuit conductors; allows inspection from below.
11.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not
install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high-power factor, T.H.D.
<15%, thermally and transient protected, RMI / RFI complies with FCC Part 18
non-consumer equipment, shut-down circuit at end of lamp life, sound rating
"A", -5°F minimum starting temperature, Type 1 outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts
70W MH M98/M143 120/277 0.67/0.28 78
100W MH M90/M140 120/277 0.90/0.43 110
Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted,
HX-HPF circuit type, high power factor, sound rating “B”, -20°F minimum starting
temperature, Type 1 Outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts
70W MH M98/M143 120/277 1.90/0.80 94
100W MH M90/M140 120/277 2.40/1.10 125
Options and Accessories
Slope Ceiling Adapters: See Specification Sheet SCA.
Fuse (magnetic ballast): Add suffix F1 or F2 to Frame-In Kit (F1=120V, F2=277V)
Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Damp Locations), CSA, I.B.E.W.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4
Calculite
®
HID Downlight C6P38MH
Page 1 of 2 6" Aperture, PAR38 Ceramic MH
70W PAR38 FLOOD MH PHILIPS 3K , LUMEN RATING = 4800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM
5,000
10,000
15,000
20,000
** EFFICIENCY = 81.6% ** CERTIFIED TEST REPORT NO. 2453FR, DATE: FEB 12, 2004
SC = .4 COMPUTED BY LSI PROGRAM **TEST-LITE**
ANGLE MEAN CP LUMENS
0 20134
5 17728 1622
10 12396
15 6288 1901
20 1851
60°
25 460 337
30 140
35 64 47
40 29
45 10 9
50 0
55 0 0
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
30°
90 0
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 479
55 0
65 0
75 0
85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 3860 80.42 98.57
0-40 3906 81.39 99.76
0-60 3916 81.59 100
0-90 3916 81.59 100
40-90 9 0.19 0.24
60-90 0 0 0
90-180 0 0 0
0-180 3916 81.59 100
CEILING 80% 70% 50% 30%
Coefficients of Utilization
WALL 70 50 30 10 50 10 50 10 50 10 0
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .97 .97 .97 .97 .95 .95 .91 .91 .87 .87 .82
1 .95 .93 .92 .91 .92 .89 .88 .87 .85 .84 .80
2 .92 .90 .88 .86 .89 .86 .86 .84 .84 .82 .79
3 .90 .88 .85 .84 .87 .83 .85 .82 .83 .81 .79
4 .89 .86 .83 .81 .85 .81 .83 .80 .82 .79 .78
5 .87 .84 .81 .79 .83 .79 .82 .78 .80 .78 .76
6 .86 .82 .80 .78 .82 .78 .81 .77 .80 .77 .76
7 .84 .80 .78 .76 .80 .76 .79 .76 .78 .75 .74
8 .83 .79 .77 .75 .78 .75 .78 .75 .77 .74 .73
9 .82 .78 .76 .74 .77 .74 .77 .73 .76 .73 .73
10 .80 .76 .74 .72 .76 .72 .76 .72 .75 .72 .71
LUMINAIRE INPUT WATTS = 78.0
100W PAR38 FLOOD MH PHILIPS 3K , LUMEN RATING = 6800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM
ANGLE MEAN CP LUMENS
0 26152
5 24195 2202
6,500
13,000
19,500
26,000
** EFFICIENCY = 81.9% ** CERTIFIED TEST REPORT NO. 2455FR, DATE: FEB 13, 2004
SC = .4 COMPUTED BY LSI PROGRAM **TEST-LITE**
10 17741
15 9134 2760
20 2934
60°
25 793 544
30 182
35 78 57
40 29
45 4 7
50 0
55 0 0
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
30°
90 0
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 221
55 0
65 0
75 0
85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 5505 80.97 98.84
0-40 5563 81.82 99.87
0-60 5570 81.92 100
0-90 5570 81.92 100
40-90 7 0.11 0.13
60-90 0 0 0
90-180 0 0 0
0-180 5570 81.92 100
CEILING 80% 70% 50% 30%
Coefficients of Utilization
WALL 70 50 30 10 50 10 50 10 50 10 0
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .98 .98 .98 .98 .95 .95 .91 .91 .87 .87 .82
1 .95 .94 .92 .91 .92 .90 .89 .87 .86 .84 .81
2 .93 .90 .89 .87 .89 .86 .86 .84 .84 .82 .80
3 .91 .88 .86 .84 .87 .83 .85 .82 .83 .81 .79
4 .89 .86 .83 .82 .85 .81 .84 .80 .82 .79 .78
5 .87 .84 .81 .79 .83 .79 .82 .78 .81 .78 .76
6 .86 .82 .80 .78 .82 .78 .81 .77 .80 .77 .76
7 .84 .81 .78 .76 .80 .76 .79 .76 .79 .75 .75
8 .83 .79 .77 .75 .78 .75 .78 .75 .77 .74 .73
9 .82 .78 .76 .74 .77 .74 .77 .74 .77 .73 .73
10 .81 .77 .74 .72 .76 .72 .76 .72 .75 .72 .72
LUMINAIRE INPUT WATTS = 110.0
70W PAR38 WIDE FLOOD MH PHILIPS 3K , LUMEN RATING = 4800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM
ANGLE MEAN CP LUMENS
0 4053
5 3975 378
1,000
2,000
3,000
4,000
** EFFICIENCY = 73.3% ** CERTIFIED TEST REPORT NO. 2454FR, DATE: FEB 12, 2004
SC = .9 COMPUTED BY LSI PROGRAM **TEST-LITE**
10 3826
15 3646 1020
20 3278
60°
25 2623 1235
30 2144
35 1451 831
40 248
45 18 55
50 0
55 0 0
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
30°
90 0
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 901
55 0
65 0
75 0
85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 5505 80.97 98.84
0-30 2632 54.84 74.81
0-40 3463 72.16 98.43
0-60 3518 73.31 100
0-90 3518 73.31 100
40-90 55 1.15 1.57
60-90 0 0 0
90-180 0 0 0
0-180 3518 73.31 100
CEILING 80% 70% 50% 30%
Coefficients of Utilization
WALL 70 50 30 10 50 10 50 10 50 10 0
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .87 .87 .87 .87 .85 .85 .81 .81 .78 .78 .73
1 .84 .82 .81 .79 .81 .78 .78 .76 .75 .74 .70
2 .81 .78 .76 .74 .77 .73 .74 .71 .72 .70 .67
3 .78 .74 .71 .69 .73 .69 .71 .67 .70 .66 .64
4 .75 .71 .68 .65 .70 .65 .68 .64 .67 .63 .62
5 .72 .67 .64 .61 .66 .61 .65 .60 .64 .60 .58
6 .69 .64 .61 .58 .64 .58 .63 .58 .62 .57 .56
7 .66 .61 .57 .55 .61 .55 .60 .55 .59 .54 .53
8 .64 .58 .54 .52 .57 .52 .57 .52 .56 .51 .50
9 .61 .55 .52 .49 .55 .49 .54 .49 .54 .49 .48
10 .58 .52 .49 .46 .52 .46 .52 .46 .51 .46 .45
LUMINAIRE INPUT WATTS = 78.0
100W PAR38 WIDE FLOOD MH PHILIPS 3K , LUMEN RATING = 6800 LMS, ELECTRONIC AROMAT BALLAST, - CL FINISH TRIM
ANGLE MEAN CP LUMENS
0 7353
5 6975 657
1,875
3,750
5,625
7,500
** EFFICIENCY = 73.7% ** CERTIFIED TEST REPORT NO. 2456FR, DATE: FEB 13,
SC = .8 2004 COMPUTED BY LSI PROGRAM **TEST-LITE**
10 6231
15 5506 1553
20 4664
60°
25 3597 1691
30 2759
35 1759 1031
40 288
45 39 74
50 14
55 3 5
60 1
65 0 0
70 0
75 0 0
80 0
85 0 0
30°
90 0
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 1960
55 178
65 0
75 0
85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 3901 57.37 77.85
0-40 4932 72.53 98.43
0-60 5010 73.68 100
0-90 5010 73.69 100
40-90 78 1.16 1.57
60-90 0 0 0
90-180 0 0 0
0-180 5010 73.69 100
CEILING 80% 70% 50% 30%
Coefficients of Utilization
WALL 70 50 30 10 50 10 50 10 50 10 0
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .88 .88 .88 .88 .86 .86 .82 .82 .78 .78 .74
1 .85 .83 .81 .80 .82 .79 .78 .76 .76 .74 .71
2 .81 .79 .77 .74 .77 .74 .75 .72 .73 .71 .68
3 .79 .75 .72 .70 .74 .70 .72 .68 .71 .67 .65
4 .76 .72 .69 .66 .71 .66 .69 .65 .68 .64 .63
5 .73 .68 .65 .62 .68 .62 .66 .62 .65 .61 .60
6 .71 .66 .62 .60 .65 .59 .64 .59 .63 .59 .58
7 .68 .62 .59 .57 .62 .56 .61 .56 .60 .56 .55
8 .65 .60 .56 .54 .59 .54 .59 .54 .58 .53 .52
9 .63 .57 .53 .51 .57 .51 .56 .51 .55 .51 .50
10 .60 .54 .51 .49 .54 .49 .54 .48 .53 .48 .47
LUMINAIRE INPUT WATTS = 110.0
Job Information Type:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504