Lightolier C6LV User Manual

Calculite
7 2 3 1 6 8 5
4
9 1/2" Dia.
2 3/4" max.
1/4" min. -
12 1/2"
3"
7 1/4" max.
6 3/4" min.*
6"
15 3/4"
1 1/4" Max. Ceiling Thk.
* 6 3/4" min. is for up to 3/4" thick ceiling.
7 3/4"
®
Evolution Recessed Downlighting C6LV
Page 1 of 1 6" Aperture PAR36 Low Voltage Non-IC Frame-In Kit
Ceiling Cutout: 6 11/16" Dia.
Frame-In Kit Reflector Trim
C6LV Adjustable Accent
C6P36A 35W - 75W PAR36 (12V)
25W PAR36 (5.5V) 35W - 75W AR111 (12V)
Features
1. Housing: Steel, 0.03" (22 ga.). Top Cover: Aluminum, 0.04" (14 ga.),
Removable for top access. Matte black finish.
2. Mounting Frame: Die-cast aluminum for dr y or plaster ceilings.
3. Retaining Springs: Precision-tooled steel springs secure reflector trim to
mounting frame for quick, tool-less installation.
4. Mounting Brackets: Galvanized steel, 0.06" (16 ga.). Adjust from inside and outside of fixture. Use 3/4" or 1 1/2" lathing channel, 1/2" EMT (by others), or optional Lightolier mounting bars.
5. Transformer: Magnetic, 120V/277V dual tap primar y, nominal 12V and
5.5V secondary.
6. Snap-In Connector s: Keyed to accept power and socket harnesses which are provided with reflector trim.
7. Junction Box: Galvanized steel .063" (14 ga.). UL Listed for maximum of 8 No. 12 AWG 90°C through branch circuit conductors. Accessible from inside and outside of fixture. Outside J-Box door is hinged for maximum opening. Snap-in plug is provided on inside cover for quick connection to power harness.
8. Thermal Protector: Meets NEC and UL requirements. Insulation must be kept 3" away from fixture sides and wiring compartments and must not be placed above fixture in a manner which will entrap heat.
9. Reflector Trim: Compatible reflector trims are listed above. See separate reflector trim specification sheets for complete catalog numbers and details.
Options & Accessories
Mounting Bars: 1950 - 18" set of (2) 1951 - 27" set of (2) T-Bars Anchor Clips: 1956 - set of (4) for use w/bars above. Wood Joist Telescoping Bars: 79 94 - set of (2) Chicago Plenum Add LC to frame suffix
Electrical
Use with dimmers rated for low voltage lamps and magnetic transformers. Consult Lightolier Controls Catalog.
Labels
UL Listed (suitable for damp locations), I.B.E.W.
US and Foreign Patents Pending.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s): Notes:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC • B0507
Loading...