Calculite
6
1
2
4
3
5
7 1/8"
(181 mm)
9 3/4" (248 mm)
5 3/4" (146 mm) DIA.
6 5/8" (168 mm) DIA.
12 1/2"
(318 mm)
®
HID Surface Cylinder C6CS-C6T6VM
Page 1 of 2 6" Aperture, T6, Ceramic Metal Halide, Medium Beam
Stem Kit
Ceiling-Mount
Wall- Mount
Reflector Trim Cylinder Housing Lamp
C6T6VM CL Specular Clear, Minimal Flange.
CCD Comfort Clear Diffuse, Minimal Flange.
CCZ Champagne Bronze, Minimal Flange.
Features
1. Upper Reflector: Clear anodized aluminum, 0.040” (16-ga.). Provides medi-
um beam optics. Also available in narrow and wide beam, see specification
sheets C6CS-C6T6VN and C6CS-C6T6VW.
2. Aperture Cone: Low brightness with 50° cut-off to lamp and lamp image.
anodizedaluminum, minimal flange. Supports captive lamp shield. Cone is
removable for relamping.
3. Cylinder Housing: Two-piece, white baked enamel seamless aluminum.
4. Socket Housing: Galvanized steel, pre-wired with G12 pulse rated socket.
Snaps onto upper reflector for secure attachment without tools; assures
proper lamp alignment to optics for consistent performance.
5. Wall Mount Back Plate: Cast aluminum, suitable for mounting over 4"
octagon outlet box.
6. Electronic Ballast: 120V or 277V. Encased, high power factor, T.H.D. <15%,
thermally and transient protected, RMI/RFI complies with FCC Part 18 noncosumer limits, shut-down circuit at end of lamp life, sound rating "A", -5° F
minimum starting temperature, Type 1 outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts
39W MH M130 120/277 0.39/0.17 44
70W MH M139 120/277 0.67/0.29 78
Ceiling-Mount Wall-Mount
C6CS39T6E1 C6CW39T6E1 Electronic 120V 39W T6 Ceramic MH
C6CS39T6E2 C6CW39T6E2 Electronic 277V 39W T6 Ceramic MH
C6CS70T6E1 C6CW70T6E1 Electronic 120V 70W T6 Ceramic MH
C6CS70T6E2 C6CW70T6E2 Electronic 277V 70W T6 Ceramic MH
Options and Accessories
C4CSW: Stem Kit – White (45°Swivel, 37" Long)
Provided with 5/8" dia. Stem and 5 1/2" Canopy.
Self-aligning swivel provides max. 45° vertical tilting.
Installs over 4" octagonal outlet box.
Stem can be cut to length on site.
Labels
UL (Suitable for Wet Locations), CSA, I.B.E.W.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4
Calculite
®
HID Surface Cylinder C6CS-C6T6VM
Page 2 of 2 6" Aperture, Ceramic Metal Halide, T6 Medium Beam
39W T6 PHILIPS CERAMIC MH LAMP, LUMEN RATING = 3400 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH TRIM
CANDLEPOWER DISTRIBUTION
ANGLE MEAN CP LUMENS
0 2382
5 2347 223
625
1,250
1,875
2,500
** EFFICIENCY = 64.3% ** CERTIFIED TEST REPORT NO. 2337FR, DATE: OCT 24, 2003
SC = 0.9 COMPUTED BY LSI PROGRAM **TEST-LITE**
10 2265
15 2086 581
20 1766
25 1385 648
60°
30 1062
35 836 518
40 566
45 248 209
50 20
55 3 6
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
30°
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 21039
55 301
65 5
75 19
85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 1452 42.71 66.44
0-40 1970 57.94 90.14
0-60 2185 64.28 99.99
0-90 2185 64.28 100
40-90 215 6.34 9.86
60-90 0 0 0.01
90-180 0 0 0
0-180 2185 64.28 100
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .77 .77 .77 .77 .75 .75 .72 .72 .69 .69 .64
1 .74 .72 .71 .69 .71 .68 .68 .66 .66 .64 .61
2 .71 .68 .66 .64 .67 .63 .65 .62 .63 .61 .58
3 .68 .64 .61 .59 .63 .59 .62 .58 .60 .57 .55
4 .65 .61 .58 .55 .60 .55 .59 .54 .57 .54 .52
5 .62 .57 .54 .52 .57 .51 .56 .51 .55 .50 .49
6 .59 .54 .51 .49 .54 .48 .53 .48 .52 .48 .47
7 .56 .51 .48 .45 .51 .45 .50 .45 .49 .45 .44
8 .54 .48 .45 .42 .48 .42 .47 .42 .47 .42 .41
9 .51 .46 .42 .40 .45 .40 .45 .39 .44 .39 .38
10 .49 .43 .39 .37 .43 .37 .42 .37 .42 .37 .36
70W T6 PHILIPS CERAMIC MH LAMP, LUMEN RATING = 6600 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH TRIM
CANDLEPOWER DISTRIBUTION
1,000
2,000
3,000
4,000
** EFFICIENCY = 62.8% ** CERTIFIED TEST REPORT NO. 2335FR, DATE: OCT 14, 2003
SC = 0.9 COMPUTED BY LSI PROGRAM **TEST-LITE**
ANGLE MEAN CP LUMENS
0 4188
5 4141 394
10 4047
15 3813 1062
20 3312
25 2664 1244
60°
30 2115
35 1667 1031
40 1114
45 479 408
50 32
55 3 8
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
30°
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 40627
55 293
65 0
75 0
85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 2700 40.92 65.12
0-40 3731 56.53 89.97
0-60 4147 62.84 100
0-90 4147 62.84 100
40-90 416 6.3 10.03
60-90 0 0 0
90-180 0 0 0
0-180 4147 62.84 100
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .76 .76 .76 .76 .74 .74 .70 .70 .67 .67 .63
1 .72 .71 .69 .68 .70 .67 .67 .65 .65 .63 .60
2 .69 .67 .65 .62 .66 .62 .63 .60 .62 .59 .57
3 .66 .63 .60 .58 .62 .57 .60 .57 .59 .56 .54
4 .64 .59 .56 .54 .59 .54 .57 .53 .56 .52 .51
5 .61 .56 .53 .50 .55 .50 .54 .50 .53 .49 .48
6 .58 .53 .50 .47 .52 .47 .51 .47 .51 .46 .45
7 .55 .50 .46 .44 .49 .44 .49 .44 .48 .43 .42
8 .53 .47 .43 .41 .46 .41 .46 .41 .45 .41 .40
9 .50 .44 .41 .38 .44 .38 .43 .38 .43 .38 .37
10 .47 .41 .38 .36 .41 .36 .41 .35 .40 .35 .34
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
LUMINAIRE INPUT WATTS = 44
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
LUMINAIRE INPUT WATTS = 78
Job Information Type:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504