Lightolier C6CS-C6T6VM User Manual

Calculite
37"
(940 mm)
6
1
2
4
3
5
7 1/8"
(181 mm)
9 3/4" (248 mm)
5 3/4" (146 mm) DIA. 6 5/8" (168 mm) DIA.
12 1/2"
(318 mm)
®
HID Surface Cylinder C6CS-C6T6VM
Page 1 of 2 6" Aperture, T6, Ceramic Metal Halide, Medium Beam
Stem Kit
Ceiling-Mount
Wall- Mount
Reflector Trim Cylinder Housing Lamp
C6T6VM CL Specular Clear, Minimal Flange.
CCD Comfort Clear Diffuse, Minimal Flange. CCZ Champagne Bronze, Minimal Flange.
Features
1. Upper Reflector: Clear anodized aluminum, 0.040” (16-ga.). Provides medi-
um beam optics. Also available in narrow and wide beam, see specification sheets C6CS-C6T6VN and C6CS-C6T6VW.
2. Aperture Cone: Low brightness with 50° cut-off to lamp and lamp image. anodizedaluminum, minimal flange. Supports captive lamp shield. Cone is removable for relamping.
3. Cylinder Housing: Two-piece, white baked enamel seamless aluminum.
4. Socket Housing: Galvanized steel, pre-wired with G12 pulse rated socket.
Snaps onto upper reflector for secure attachment without tools; assures proper lamp alignment to optics for consistent performance.
5. Wall Mount Back Plate: Cast aluminum, suitable for mounting over 4" octagon outlet box.
6. Electronic Ballast: 120V or 277V. Encased, high power factor, T.H.D. <15%, thermally and transient protected, RMI/RFI complies with FCC Part 18 non­cosumer limits, shut-down circuit at end of lamp life, sound rating "A", -5° F minimum starting temperature, Type 1 outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts
39W MH M130 120/277 0.39/0.17 44 70W MH M139 120/277 0.67/0.29 78
Ceiling-Mount Wall-Mount C6CS39T6E1 C6CW39T6E1 Electronic 120V 39W T6 Ceramic MH C6CS39T6E2 C6CW39T6E2 Electronic 277V 39W T6 Ceramic MH C6CS70T6E1 C6CW70T6E1 Electronic 120V 70W T6 Ceramic MH C6CS70T6E2 C6CW70T6E2 Electronic 277V 70W T6 Ceramic MH
Options and Accessories
C4CSW: Stem Kit – White (45°Swivel, 37" Long)
Provided with 5/8" dia. Stem and 5 1/2" Canopy. Self-aligning swivel provides max. 45° vertical tilting. Installs over 4" octagonal outlet box. Stem can be cut to length on site.
Labels
UL (Suitable for Wet Locations), CSA, I.B.E.W.
Job Information Type:
Job Name: Cat. No.:
Lamp(s): Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4
Calculite
®
HID Surface Cylinder C6CS-C6T6VM
Page 2 of 2 6" Aperture, Ceramic Metal Halide, T6 Medium Beam
39W T6 PHILIPS CERAMIC MH LAMP, LUMEN RATING = 3400 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH TRIM
CANDLEPOWER DISTRIBUTION
ANGLE MEAN CP LUMENS
0 2382 5 2347 223
625
1,250
1,875
2,500
** EFFICIENCY = 64.3% ** CERTIFIED TEST REPORT NO. 2337FR, DATE: OCT 24, 2003 SC = 0.9 COMPUTED BY LSI PROGRAM **TEST-LITE**
10 2265 15 2086 581 20 1766 25 1385 648
60°
30 1062 35 836 518 40 566 45 248 209 50 20 55 3 6 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
30°
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 21039 55 301 65 5 75 19 85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 1452 42.71 66.44 0-40 1970 57.94 90.14 0-60 2185 64.28 99.99
0-90 2185 64.28 100 40-90 215 6.34 9.86 60-90 0 0 0.01
90-180 0 0 0
0-180 2185 64.28 100
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .77 .77 .77 .77 .75 .75 .72 .72 .69 .69 .64 1 .74 .72 .71 .69 .71 .68 .68 .66 .66 .64 .61 2 .71 .68 .66 .64 .67 .63 .65 .62 .63 .61 .58 3 .68 .64 .61 .59 .63 .59 .62 .58 .60 .57 .55 4 .65 .61 .58 .55 .60 .55 .59 .54 .57 .54 .52 5 .62 .57 .54 .52 .57 .51 .56 .51 .55 .50 .49 6 .59 .54 .51 .49 .54 .48 .53 .48 .52 .48 .47 7 .56 .51 .48 .45 .51 .45 .50 .45 .49 .45 .44 8 .54 .48 .45 .42 .48 .42 .47 .42 .47 .42 .41 9 .51 .46 .42 .40 .45 .40 .45 .39 .44 .39 .38 10 .49 .43 .39 .37 .43 .37 .42 .37 .42 .37 .36
70W T6 PHILIPS CERAMIC MH LAMP, LUMEN RATING = 6600 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH TRIM
CANDLEPOWER DISTRIBUTION
1,000
2,000
3,000
4,000
** EFFICIENCY = 62.8% ** CERTIFIED TEST REPORT NO. 2335FR, DATE: OCT 14, 2003 SC = 0.9 COMPUTED BY LSI PROGRAM **TEST-LITE**
ANGLE MEAN CP LUMENS
0 4188
5 4141 394 10 4047 15 3813 1062 20 3312 25 2664 1244
60°
30 2115 35 1667 1031 40 1114 45 479 408 50 32 55 3 8 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
30°
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 40627 55 293 65 0 75 0 85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 2700 40.92 65.12 0-40 3731 56.53 89.97 0-60 4147 62.84 100
0-90 4147 62.84 100 40-90 416 6.3 10.03 60-90 0 0 0
90-180 0 0 0
0-180 4147 62.84 100
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .76 .76 .76 .76 .74 .74 .70 .70 .67 .67 .63 1 .72 .71 .69 .68 .70 .67 .67 .65 .65 .63 .60 2 .69 .67 .65 .62 .66 .62 .63 .60 .62 .59 .57 3 .66 .63 .60 .58 .62 .57 .60 .57 .59 .56 .54 4 .64 .59 .56 .54 .59 .54 .57 .53 .56 .52 .51 5 .61 .56 .53 .50 .55 .50 .54 .50 .53 .49 .48 6 .58 .53 .50 .47 .52 .47 .51 .47 .51 .46 .45 7 .55 .50 .46 .44 .49 .44 .49 .44 .48 .43 .42 8 .53 .47 .43 .41 .46 .41 .46 .41 .45 .41 .40 9 .50 .44 .41 .38 .44 .38 .43 .38 .43 .38 .37 10 .47 .41 .38 .36 .41 .36 .41 .35 .40 .35 .34
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
LUMINAIRE INPUT WATTS = 44
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
LUMINAIRE INPUT WATTS = 78
Job Information Type:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504
Loading...