10 1/2"
(267mm)
5 3/4" (146mm)
4 1/2" (115mm)
8137
1911
12 2
6
3
10 1/2" (93mm)
9 1/8" (93mm)
5
9 5/16" (237mm)
4
10
Vertical Adjustment 5/8" (16mm) 2 7/8" (73mm)
20" (508mm) to 30" (762mm)
18 1/2" (470mm)
2" (51mm) max. ceiling thk.
13 3/8" (340mm)
14
®
ColorWash C4X9LEDLW240
Page 1 of 2 4 1/2" X 9 1/8" Aperture, LED Color-Changing Matrix® Wall Washer for Export
Ordering Information
Solid State Lighting Unit Light Source Frame-In Kit Line Voltage
White Flange Polished Flange Finish
C4X9LEDLWCLW C4X9LEDLWCLP C4X9LEDLWCCLW C4X9LEDLWCCLP
C4X9LEDLWCCDW C4X9LEDLWCCDP
Specular Clear
Comfort Clear
Comfort Clear Diffuse
RGBA LED Array
C4X9CCLEDLW240
240, 50Hz
Features
1. Heat Sink Housing: Die-cast aluminum, design thermally optimized to
reduce LED junction temperature to maintain light output, color and life.
2. LED Array: Series of 48 high-power red, green, blue and amber (RGBA)
LEDs generate millions of colors and high quality white light at variable color temperatures. Static colors and dynamic effects are programmable by DMX controls. Average expected life, under normal operating conditions is 50,0 00 hours with lumen maintenance of 70% of original light output. Factory calibrated integral color sensor and self-adjusting feedback soft ware guarantee color consistency over life.
3. Aper ture Cone: Pre-finished aluminum, 55° visual and reflected cutoff.
Overlap flange accommodates different ceiling types, white or polished flange. Precision mitered flange corner. 4. MicroBlend optics: Internal collective mixing technology ensures smooth washing and color uniformit y and eliminates undesirable color fringing.
5. Aper ture Lens: Tempered glass, fine texture provides additional mixing at
the aperture and minimizes the appearance of the individual RGBA sources.
6. Torsiontite Springs: Secure solid state lighting module tight against ceiling
surface without sagging. Accommodates ceilings from ½” to 2” thick.
7. Power Supply Unit /Slave Control Drive Module: PSU: 240VAC 50/60
Hz., Class 2, high power factor, FCC Class B approved, short circuit protection. SCD: low voltage DC, provides power and data to control LED array with a maximum of 8 LED channels. Electronics are enclosed in a black extruded aluminum housing providing optimal thermal dissipation for reliable operation and long life. Module is replaceable from below the ceiling.
8. DMX Connectors: Two RJ45 jacks mounted at one end of PSU/SCD module
provide DMX512-In and DMX512-Out connections (see page 2). Uses standard shielded, plenum rated, CAT5 round, 8 conductor, twisted pair, network cables (not supplied).
9. Flexible Metal Conduit/Quick Connector: Quick connector for easy field
data connection.
10. Mounting Frame: 0.048" thk., galv. steel.
Features (continued)
11. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism
accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set
prior to installation.
12. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to
30"long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without
accessories.
13. Junction Box: UL and cUL Listed for through branch circuit wiring with max.
of (8) No. 12 AWG, 90 ºC supply conductors.
14. Thermal Protector: Meets (NEC) UL and (CEC) CSA requirements. Insulation
must be kept 3" away from fixture sides and wiring compartments and must not be placed above fixture in a manner which will entrap heat.
Electrical
240V, 50/60Hz: Input Watts: 75W Max.
Labels
cULus Listed for dr y locations. I.B.E.W.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s): Notes:
Lightolier is a Philips group brand
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • A0708
Lightolier Lytemode
DMX Master Station
LIGHTOLIER
LYTEMODEÆ
DMX CONTROL
SYSTEM
Strand Lighting
Accent DMX
CAT5 (8) wires round cable with RJ45 plugs (by others)
DMX512 Out
DMX512 In
DMX512 Out To Next Luminarie
or
DMX512 Out
DMX512 In
120VAC 60 HZ. Power Input
RJ45 DMX Terminator (Required to terminate the last luminaire in the same data line)
DMX512 Out
Shielded CAT5 9 Pin Connector Wiring
ILS Network (optional)
Mini Master
(order seperately)
Stand-Alone Accent DMX
Entertainment Technology
DMX Control
Connected Console or Computer to create scenes
OPTIONS DMX512 Systems*
RJ45 jacks
Color-Changing Lensed Wall Washer
Horizon 512 Channel DMX Interface or others
Other Standard
DMX512 Interface
Control
DMX Interface XLR-5 Port (Female)
Receptacle (By Others)
DMX512 Cable
DMX512 In
RJ45 jacks
Color-Changing Lensed Wall Washer
240VAC 50/60HZ. Power Input240VAC 50/60HZ. Power Input
CAT5 (8) wires round cable with RJ45 plugs (by others)
* All systems shown are stand-alone. For additional information and other DMX systems, please visit http://www.genlyte.com/" for link to each manufacturer web site.
Input Power 120 - 240VAC 50/60HZ.
XLR-5(Femal port)
MARQUEEÆ PC DMX INTERFACE
USB Port to PC
DMX512 Cable
®
ColorWash C4X9LEDLW240
Page 2 of 2 4 1/2" X 9 1/8" Aperture, LED Color-Changing Matrix® Wall Washer for Export
Lighting Data (All data is based on 3000K color temperature)
Example: With multiple units located
Color Temperature: 3000K
Repor t No: 22905
2' Fro m Wall - Single 2' Fro m Wall - 2' On Center 2' Fro m Wall - 3' On Center 2' Fro m Wall - 4' On Center
1 1 4 27 4 1 1 38 34 38 1 31 18 31 1 28 9 28 2 1 8 34 8 1 2 54 52 54 2 41 30 41 2 37 17 37 3 1 9 24 9 1 3 46 45 46 3 32 29 32 3 27 18 27
4 2 7 14 7 2 4 33 33 33 4 23 22 23 4 18 15 18 5 2 5 8 5 2 5 24 24 24 5 16 16 16 5 12 11 12
6 1 3 5 3 1 6 18 18 18 6 12 12 12 6 9 9 9 7 1 2 3 2 1 7 13 13 13 7 9 9 9 7 7 7 7
8 1 2 2 2 1 8 10 10 10 8 7 7 7 8 5 5 5 9 1 1 1 1 1 9 9 8 9 9 6 6 6 9 4 4 4
3' Fro m Wall - Single 3' Fro m Wall - 3' On Center 3' Fro m Wall - 4' On Center 3' Fro m Wall - 5' On Center 3' From W all - 6' On Center
1 1 3 8 3 1 1 12 10 12 1 10 7 10 1 9 3 9 1 9 3 9 2 1 6 15 6 1 2 22 20 22 2 18 13 18 2 16 6 16 2 16 6 16 3 2 7 15 7 2 3 25 24 25 3 20 18 20 3 18 12 18 3 17 8 17
4 2 7 13 7 2 4 23 23 23 4 18 16 18 4 16 12 16 4 14 9 14 5 2 6 9 6 2 5 19 19 19 5 14 14 14 5 12 11 12 5 11 8 11
6 2 5 6 5 2 6 16 16 16 6 12 11 12 6 10 9 10 6 8 7 8 7 2 3 4 3 2 7 13 13 13 7 9 9 9 7 8 7 8 7 7 6 7
8 2 3 3 3 2 8 10 10 10 8 7 7 7 8 6 6 6 8 5 5 5 9 1 2 2 2 1 9 9 8 9 9 6 6 6 9 5 5 5 9 4 4 4
3' from wall and spaced 4' on center, the illumination on the wall 3' down from ceiling will be 20 f.c. beneath units and 16 f.c. between units. Footcandle values are averaged and rounded off and are based on a minimum of five units.
DMX Network
Lightolier is a Philips group brand
Accessories
Addressable Interface Kit: Cat. No. CLEDAIK
Load addresses and select operating mode for DMX protocol, load serial numbers and specific lighting preset, update firmware to each LED lighting unit
DMX Terminator: Cat. No. CLEDDMXTERM Stepdown Transformer: Cat. No. 7997.
Supplies 120V fixture from a 277V 60Hz. branch circuit (20 amp. minimum). Can be used up to (4) fixtures (not to exceed 300W maximum load).
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • A0708