Lightolier C4X4MRWCLW User Manual

Calculite
8.16"
9.66"
8"
9.66"
2" Max. Ceiling Thickness
5.75"
4.5"
®
Matrix HID Lensed Adj. Accent C4X4MRW
Page 1 of 1 4½" X 4½" Square Aperture (1) 20W CMH MR16
Ceiling Cutout: 5 1/4" x 5 1/4 " (130 mm x 130mm) Dia.
Ordering Information
Frame-In Kits Reflector Trims Finish/Flange Lamp
C4X420MREU Electronic 120/277V
C4X4MRWCLW C4X4MRWCLP C4X4MRWCCLW C4X4MRWCCLP C4X4MRWCCDW C4X4MRWCCDP C4X4MRWWHW
Specular Clear/White Specular Clear/Polished Comfort Clear/White Comfort Clear/Polished Comfort Clear Diffuse/White Comfort Clear Diffuse/Polished White/ White
(1) 20W MR16 CMH GXIC Base
Features
1. Reflector Trim: 55° physical and reflected cutoff. Available with integral
flange painted white or polished to match inside of cone.
2. Lamp Holder/Trim Adjustment Assembly: Unitized optics ensure
alignment of lamp and aperture cone regardless of ceiling thickness. Patented EZ Aim™ gear-driven adjustment features an optimized lamp path to maximize light output at tilt angles up to 45°. Aiming indicator ensures accurate lamp positioning. Solite lens ships standard. Adjust trim kit vertically to accommodate up to 2" thick ceiling.
3. Socket: Twist and lock base. 5kV (600V) pulse rated PPS, black T240 body
socket with nickel-plated contacts. 18 AWG silicone leads with fiberglass outer sleeve.
4. Frame Housing: Steel, 0.029" (22-Ga.), matte black finish. Removable cover
for top relamping.
5. Frame Vertical Adjustment Mechanism: Accommodates mounting to
virtually any ceiling system using pre-installed mounting bars, or ½" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. Final adjustment can be made from below from inside the fixture.
6. Mounting Bars: Galvanized steel, 0.048" (18-ga.), pre-installed telescoping
bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories.
7. Retention Springs: Rust resistant springs secure trim for quick, tool-less
installation.
8. Ballast/Cover Assembly: Accessible from below and removable without
tools for inspection and ballast replacement.
9. Junction Box: 0.059" (16-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90°C through branch circuit conductors. Allows inspection from below.
10. Thermal Protector: Meets NEC and UL requirements. Do not install
insulation above nor within 3" (76mm) of any part of the luminaire.
11. Electronic Ballast: 120 or 277V, 50/60 Hz., encased, high power factor
>0.99, THD <10%, thermally and transient protected, RMI/RFI complies with FCC Part 18 non-consumer limits, shut-down at end of lamp life, sound rating “A", Minimum starting temperature -30°, Type 1 Outdoor rating.
Features (continued)
Ballast ANSI Code Voltage Max. Amps Input Watts
20W MH M156 120/277V 0.20/0.09 22
Options and Accessories
Accepts one optical accessory 2" diameter color filter/specialty filter: ADF2/AF2 2" diameter louver: AL2HC
Labels
UL, cUL (Suitable For Wet Locations)
Job Name:
Cat. No.:
Lamp(s): Notes:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC • A0507
Calculite
2400
1800
1200
600
30°
60°
500
1000
1500
2000
30°
60°
1200
900
600
300
30°
60°
®
Matrix HID Lensed Adj. Accent C4X4MRW
Page 2 of 2 4½" X 4½" Square Aperture (1) 20W CMH MR16
(FC) is initial footcandles at center of beam. Beam length (L) and beam width (W) are to where the candlepower is reduced to 50% of the center beam candlepower. (C) is the distance to the center of the beam.
4 ½" x 4 ½" Aperture 20W CMH MR16 - 12°
An gle CP 0 117
5 166 10 297 15 644 20 1352 25 2138 30 2595 35 2154 40 1201 45 476 50 159 55 26 60 0 65 0 70 0 75 0 80 0 85 0 90 0
20W G.E.HID MR16 12° SP, GX10 BASE
Lamp @ 30° Vertical Tilt
Lumen Rating = 1000 LMS. CBCP = 2595 CD Beam Angle = 16° Test Report No. 3421FR
30° Aiming Angle - Horizontal Surface D C FC L W
6' 3.5' 47 1.7' 1.5' 8' 4.6' 26 2.3' 1.9' 10' 5.8' 17 2.8' 2.4' 12' 6.9' 12 3.4' 2.9' 14' 8.1' 9 3.9' 3.4'
30° Aiming Angle - Vertical Surface D C FC L W
2' 3.5' 81 1.7' 0.8' 3' 5.2' 36 2.6' 1.3' 4' 6.9' 20 3.5' 1.7' 5' 8.7' 13 4.3' 2.1' 6' 10.4' 9 5.2' 2.5'
4 ½" x 4 ½" Aperture 20W CMH MR16-25°
An gle CP
0 165 5 210 10 335 15 628 20 1107 25 1630 30 1914 35 1730 40 1075 45 453 50 104 55 7 60 2 65 1 70 1 75 1 80 1 85 1 90 1
4 ½" x 4 ½" Aperture 20W CMH MR16-40°
An gle CP 0 134
5 241 10 417 15 676 20 940 25 1128 30 1214 35 1164 40 928 45 541 50 225 55 43 60 3 65 0 70 1 75 1 80 0 85 1 90 0
20W G.E.HID MR16 40° FL, GX10 BASE
Lamp @ 30° Vertical Tilt
Lumen Rating = 1000 LMS. CBCP = 1914 CD Beam Angle = 22° Test Report No. 3418FR
20W G.E.HID MR16 40° FL, GX10 BASE
Lamp @ 30° Vertical Tilt
Lumen Rating = 1000 LMS. CBCP = 1214 CD Beam Angle = 30° Test Report No. 3416FR
30° Aiming Angle - Horizontal Surface D C FC L W
6' 3.5' 35 3.1' 2.7' 8' 4.6' 19 4.2' 3.6' 10' 5.8' 12 5.2' 4.5' 12' 6.9' 9 6.3' 5.4' 14' 8.1' 6 7.3' 6.3'
30° Aiming Angle - Vertical Surface D C FC L W
2' 3.5' 60 3.5' 1.6' 3' 5.2' 27 5.3' 2.3' 4' 6.9' 15 7.0' 3.1' 5' 8.7' 10 8.8' 3.9' 6' 10.4' 7 10.5' 4.7'
30° Aiming Angle - Horizontal Surface D C FC L W
6' 3.5' 22 4.4' 3.7' 8' 4.6' 12 5.9' 5.0' 10' 5.8' 8 7.3' 6.2' 12' 6.9' 5 8.8' 7.4' 14' 8.1' 4 10.2' 8.7'
30° Aiming Angle - Vertical Surface D C FC L W
2' 3.5' 38 5.5' 2.1' 3' 5.2' 17 8.2' 3.2' 4' 6.9' 9 10.9' 4.3' 5' 8.7' 6 13.7' 5.4' 6' 10.4' 4 16.4' 6.4'
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC • A0507