Lightolier C4T4W User Manual

C4T4W
Calculite HID wall wash
Catalog number:
Notes: Type:
9
86 10 7245 31
20" (508 mm) to
9 3/16"
(233 mm)
30" (762 mm)
Top view
8 7/8"
(226 mm)
7 1/2"
(190 mm)
Page 1 of 3
Vertical adjustment
5/8" (16 mm) to
2 7/8" (73 mm)
4 1/4" (108 mm) dia.
5 1/2" (140 mm) dia.
Ceiling cutout: 5 1/8" (130 mm) diameter
Reflector trim Frame-in kit Lamping (ceramic metal halide)
C4 T4 W CLW
Features
1. Upper reflector: Cle ar anodized aluminum, 0.040 ” (16 ga.). Provides wide
beam optics ideal for general lighting and wall washing.
3. Lamp shield: High temperature glass as required by code, captive during re­lamping. Light diffusion provides extremely smooth beam.
4. Socket housing: Galvanized steel, pre-wired with G8. 5 pulse rated socket. Snaps onto reflector/housing for secure attachment without tools. Unitized construction assures proper optical alignment of lamp to reflector.
5. Mounting frame: 0.048” (18 ga.) galvanized steel. Ver tical adjustment mechanism accommodates mounting to virtu ally any ceiling system using mounting bars (provided), or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and mark ings allow fixture to be preset prior to installation.
6. Mounting ring: 0.0 48” (18 ga.) galvanized steel. Designed for ver tical adjustment from above or below for ceilings from 0” to 2” thick . Center-line notches allow consistent alignment of multiple fixtures.
7. Mounting bars: 0.048 ” (18 ga.) galvanized steel. Pre-installed , telescoping bars extend to 30” long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self- centering feature simplifies inst allation in 24” O.C. grid syste ms. At taches to steel or wood joists without accessories.
8. Trim retention springs: Rust resistant springs secure reflector/housing for quick, tool-less installation.
9. Ballast / socket housing / cover assembly: Electronic, snaps onto junction box without tools for inspection and ballast replacement, accessible from below.
10. Junction box: 0.048” (18 ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors. Allows inspection from below.
11. Thermal protector: (Not Shown) Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire.
CLP CCDW CCDP
Specular clear, white painted flange Specular clear, matching flange Comfor t clear dif fuse , white painted flange Comfor t clear dif fuse , matching flange
C420T4EU C439T4E1 C439T4E2 C4 70T4 E1 C4 70T4 E2
Electronic 120V/277V Electronic 120V Electronic 277V Electronic 120V Electronic 277V
Electrical
Electronic ballast: 120V or 277V, 50/60 Hz., encased, high power factor, T.H.D.
<15%, thermally and transient protected, RMI/RFI complies with FCC Part 18 non-consumer limits, shut- down circuit at end of lamp life, sound rating “A”, -5°F minimum starting temperature, Type 1 Outdoor rating.
Ballast ANSI Code Voltage Max. amps Input watts
20W MH M156 120/277 0.21/0.10 23 39W MH M130 120/277 0.39/0.17 44 70W MH M139 120/277 0.67/0.29 78
Options and accessories
Chicago Plenum: Consult factory.
Labels
UL (Suitable for damp locations), CSA, I.B .E.W. For 70W, inst all fixtures with minimum spacing between:
1. Center-to-center of adjacent luminaries: 2 feet .
2. Top of luminaire to overhead building member: 1/2 inch .
3. Luminaire center to side building member: 1 foot.
2" (50 mm) max.
ceiling thickness
20 W T4.5 39 W T4. 5 39 W T4. 5 70 W T4. 5 70 W T4. 5
C4T4W
Calculite HID wall wash
Page 2 of 3
Lighting data - example
C4T4WCLW illumination on the wall 5'down from the ceiling is 23.5 f.c. beneath and 22.8 f.c. between fixtures.
23.5 f.c.
22.8 f.c.
3'
23.5 f.c.
3'
5'
20W T4 GE Ceramic MH , lumen rating = 1700 LMS., Aromat 20W electronic ballast, CL f inish reflector. Report no. 2427FR
200
400
600
800
Downlight Wall wash Side Side
60°
30°
Multiple units -
footcandles on wall
2' From wall - 3' on center
3'
1 19.6 18.2 19.6 2 25.8 26.7 25.8 3 27.5 26.7 27.4 4 24.8 23.8 24.8 5 20.2 20.1 20.2 6 16.9 16.8 16.9 7 13.9 13.7 13.9 8 11.8 11.7 11.8 9 10.2 10.1 10.2 10 8.9 8.9 8.9 11 8.1 8.1 8.1 12 7.5 7.5 7.5 13 7.1 7.1 7.1
Distance from ceiling in feet
14 6.9 6.8 6.9
Multiple units -
footcandles on wall
3' From wall - 3' on center
3'
1 15.6 9.7 15.6 2 19.2 15.2 19.2 3 18.2 18.5 18.1 4 16.8 16.0 16.8 5 14.3 12.9 14.3 6 11.7 11.1 11.7 7 9.4 9.3 9.4 8 8.0 8.0 8.0 9 6.9 6.8 6.9 10 6.1 6.0 6.1 11 5.5 5.5 5.5 12 5.1 5.1 5.1 13 4.8 4.8 4.8
Distance from ceiling in feet
14 4.7 4.7 4.7
Multiple units -
footcandles on wall
3' From wall - 4' on center
4'
1 6.5 6.3 6.5 2 11.5 11.1 11.5 3 12.1 12.6 12.1 4 12.7 12.9 12.7 5 13.0 12.3 13.0 6 11.8 11.4 11.8 7 10.5 10.4 10.5 8 9.3 9.3 9.3 9 8.4 8.3 8.4 10 7.6 7.5 7.6 11 6.9 6.8 6.9 12 6.3 6.3 6.3 13 5.9 5.8 5.9
Distance from ceiling in feet
14 5.6 5.5 5.6
39W T4 Philips Ceramic MH, lumen rating = 3300 LMS., Aromat 39W electronic ballast, CL finish reflector. Report no. 2426FR
375
60°
750
1,125
30°
1,500
Downlight Wall wash Side Side
Multiple units -
footcandles on wall
2' From wall - 3' on center
3'
1 32.2 20.3 32.2 2 34.1 28.4 34.1 3 33.7 31.7 33.7 4 30.8 30.7 30.8 5 26.9 24.9 26.9 6 22.1 21.4 22.1 7 17.8 17.8 17.8 8 15.2 15.3 15.2 9 13.2 13.2 13.2 10 11.6 11.6 11.6 11 10.5 10.5 10.5 12 9.7 9.7 9.7 13 9.2 9.2 9.2
Distance from ceiling in feet
14 8.9 8.9 8.9
Multiple units -
footcandles on wall
3' From wall - 3' on center
3'
1 13.6 13.2 13.6 2 23.4 22.5 23.4 3 22.4 22 22.4 4 22.5 22.5 22.5 5
23.5 22.8 23.5 6 22.1 21.6 22.1 7 19.9 19.8 19.9 8 17.8 17.9 17.8 9 16 16 16 10 14.4 14.4 14.4 11 13.2 13 13.2 12 12.1 12 12.1 13 11.2 11.2 11.2
Distance from ceiling in feet
14 10.6 10.6 10.6
Multiple units -
footcandles on wall
3' From wall - 4' on center
4'
1 10.2 8.4 10.2 2 18.5 14.8 18.5 3 16.7 15.3 16.7 4 17 15.8 17 5 16.7 17.1 16.7 6 16.3 15.6 16.2 7 14.9 14 14.9 8 13.1 12.7 13.1 9 11.6 11.5 11.6 10 10.3 10.4 10.3 11 9.3 9.4 9.3 12 8.5 8.6 8.5 13 7.9 7.9 7.9
Distance from ceiling in feet
14 7.4 7.5 7.4
Loading...