Lightolier C4T4VN User Manual

Calculite
®
HID Downlight C4T4VN
Page 1 of 2 4 1/2” Aperture, 2pc Vertical, T4.5 Narrow Beam
Ceiling Cutout: 5 1/8” (130 mm) Dia.
Reflector Trim Frame-In Kit Lamp
C4T4VN CLW Specular Clear, White Painted Flange.
CLP Specular Clear, Matching Flange. CCDW Comfort Clear Diffuse, White Painted Flange. CCDP Comfort Clear Diffuse, Matching Flange. CCZW Champagne Bronze, White Painted Flange. CCZP Champagne Bronze, Matching Flange.
C420T4E1 Electronic 120V 20W T4.5 Ceramic Metal Halide C420T4E2 Electronic 277V 20W T4.5 Ceramic Metal Halide C439T4E1 Electronic 120V 39W T4.5 Ceramic Metal Halide C439T4E2 Electronic 277V 39W T4.5 Ceramic Metal Halide C470T4E1 Electronic 120V 70W T4.5 Ceramic Metal Halide C470T4E2 Electronic 277V 70W T4.5 Ceramic Metal Halide
Features
1. Upper Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides
medium beam optics ideal for general lighting. Also available in medium and wide beam, see C4T4VM and C4T4VW specification sheets.
2. Aperture Cone: Provides 50° visual cut-off to lamp and lamp image; self-flange in painted white or aperture-matching polished flange. Consult factory for other finishes.
3. Lamp Shield: High-temperature glass as required by code, captive during re-lamping. Light diffusion provides exceptionally smooth beam.
4. Socket Housing: Galvanized steel, pre-wired with G8.5 pulse rated socket. Snaps onto upper reflector for secure attachment without tools; unitized construction assures proper lamp alignment to optics for consistent performance.
5. Mounting Frame: 0.048" (18-ga.) galvanized steel. Vertical adjustment mech­anism accommodates mounting to virtually any ceiling system using mounting bars (provided, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be preset prior to installation.
6. Mounting Ring: 0.048"(18-ga.) galvanized steel. Designed for vertical adjustment from above or below for ceilings from 0" to 2" thick. Center-line notches allow consistent alignment of multiple fixtures.
7. Mounting Bars: 0.048" (18-ga.) pre-installed, telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories.
8. Trim Retention Springs: Rust resistant springs secure reflector/housing for quick, tool-less installation.
9. Ballast / Socket Housing / Cover Assembly: Snaps onto junction box without tools for inspection and ballast replacement, accessible from below.
10.Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors. Allows inspection from below.
11.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Electronic Ballast: 120 or 277V, 50/60 Hz., encased, high power
factor, T.H.D. <15%, thermally and transient protected, RMI/RFI complies with FCC Part 18 non-consumer limits, shut-down circuit at end of lamp life, sound rating “A”, -5°F minimum starting temperature, Type 1 Outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts
20W MH M156 120/277 0.21/0.10 23 39W MH M130 120/277 0.39/0.17 44 70W MH M139 120/277 0.67/0.29 78
Options and Accessories
Slope Ceiling Adapters: See Specification Sheet SCA. Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Damp Locations), CSA, I.B.E.W. For 70W, install fixtures with minimum spacing between:
1. Center-to center of adjacent luminaries: 2 feet.
2. Top of luminaire to overhead building member: 1/2 inch.
3. Luminaire center to side building member: 1 foot.
Job Information Type:
Job Name: Cat. No.:
Lamp(s): Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504
Calculite
®
HID Downlight C4T4VN
Page 2 of 2 4 1/2” Aperture, 2pc Vertical, T4.5 Narrow Beam
20W T4 GE CMH LAMP, LUMEN RATING = 1700 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH TRIM
CANDLEPOWER DISTRIBUTION
ANGLE MEAN CP LUMENS
0 2340 5 2039 189
10 1505
625
1,250
1,875
2,500
** EFFICIENCY = 58.0% ** CERTIFIED TEST REPORT NO. 2401FR, DATE: DEC 22, 2003 SC = 0.4 COMPUTED BY LSI PROGRAM **TEST-LITE**
15 1047 306 20 720 25 490 237
60°
30 351 35 270 173 40 209 45 96 79 50 6 55 0 1 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
30°
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 13228
55 32 65 8 75 0 85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 732 43.09 74.35 0-40 905 53.24 91.87 0-60 985 57.95 100.0
0-90 985 57.95 100.0 40-90 80 4.71 8.13 60-90 0 0.0 0.0
90-180 0 0.0 0.0
0-180 985 57.95 100.00
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .69 .69 .69 .69 .67 .67 .64 .64 .62 .62 .58 1 .67 .65 .64 .63 .64 .62 .62 .60 .60 .58 .56 2 .64 .62 .60 .59 .61 .58 .59 .57 .58 .55 .54 3 .62 .59 .57 .55 .58 .55 .57 .54 .55 .53 .51 4 .60 .56 .54 .52 .56 .52 .54 .51 .53 .50 .49 5 .57 .54 .51 .49 .53 .49 .52 .48 .51 .48 .47 6 .55 .51 .49 .47 .51 .47 .50 .46 .49 .46 .45 7 .53 .49 .46 .44 .49 .44 .48 .44 .47 .44 .43 8 .51 .47 .44 .42 .46 .42 .46 .42 .45 .42 .41 9 .49 .45 .42 .40 .44 .40 .44 .40 .43 .40 .39 10 .47 .43 .40 .38 .42 .38 .42 .38 .42 .38 .37
LUMINAIRE INPUT WATTS = 23
39W T4 PHILIPS CMH LAMP, LUMEN RATING = 3300 LMS, AROMAT BALLAST, CL FINISH TRIM
CANDLEPOWER DISTRIBUTION
ANGLE MEAN CP LUMENS
0 3301 5 2998 281
10 2493
875
1,750
2,625
3,500
** EFFICIENCY = 57.2% ** CERTIFIED TEST REPORT NO. 2400FR, DATE: DEC 22, 2003 SC = 0.6 COMPUTED BY LSI PROGRAM **TEST-LITE**
15 1946 556 20 1462 25 1061 506
60°
30 788 35 609 383 40 435 45 185 158 50 10 55 0 2 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
30°
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 25548
55 0 65 0 75 0 85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 1343 40.71 71.2 0-40 1726 52.33 91.52 0-60 1886 57.17 100
0-90 1886 57.17 100 40-90 159 4.85 8.48 60-90 0 0 0
90-180 0 0 0
0-180 1886 57.17 100
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .68 .68 .68 .68 .67 .67 .64 .64 .61 .61 .57 1 .66 .64 .63 .62 .63 .61 .61 .59 .59 .58 .55 2 .63 .61 .59 .57 .60 .57 .58 .56 .57 .55 .53 3 .61 .58 .56 .54 .57 .53 .56 .52 .54 .52 .50 4 .58 .55 .52 .51 .54 .50 .53 .50 .52 .49 .48 5 .56 .52 .49 .47 .52 .47 .51 .47 .50 .46 .45 6 .54 .50 .47 .45 .49 .45 .49 .44 .48 .44 .43 7 .52 .47 .44 .42 .47 .42 .46 .42 .45 .42 .41 8 .50 .45 .42 .40 .44 .40 .44 .40 .43 .40 .39 9 .47 .43 .40 .38 .42 .38 .42 .37 .41 .37 .37 10 .45 .40 .38 .36 .40 .36 .40 .36 .39 .35 .35
LUMINAIRE INPUT WATTS = 44
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
70W T4 PHILIPS CMH LAMP, LUMEN RATING = 6400 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH TRIM
CANDLEPOWER DISTRIBUTION
1,375
2,750
4,125
5,500
** EFFICIENCY = 57.0% ** CERTIFIED TEST REPORT NO. 2397FR, DATE: DEC 18, 2003 SC = 0.6 COMPUTED BY LSI PROGRAM **TEST-LITE**
ANGLE MEAN CP LUMENS
0 5645
5 5314 498 10 4588 15 3673 1044 20 2797 25 2083 989
60°
30 1582 35 1220 770 40 878 45 386 322 50 14 55 0 3 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
30°
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 53412
55 0 65 0 75 0 85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 2530 39.54 69.8 0-40 3299 51.56 91.02 0-60 3625 56.65 100
0-90 3625 56.65 100 40-90 325 5.09 8.98 60-90 0 0 0
90-180 0 0 0
0-180 3625 56.65 100
Coefficients of Utilization
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .68 .68 .68 .68 .66 .66 .63 .63 .61 .61 .57 1 .65 .64 .63 .62 .63 .61 .60 .59 .58 .57 .54 2 .63 .60 .59 .57 .59 .56 .58 .55 .56 .54 .52 3 .60 .57 .55 .53 .56 .53 .55 .52 .54 .51 .49 4 .58 .54 .52 .50 .54 .49 .53 .49 .51 .48 .47 5 .55 .51 .49 .47 .51 .46 .50 .46 .49 .46 .44 6 .53 .49 .46 .44 .49 .44 .48 .44 .47 .43 .42 7 .51 .46 .43 .42 .46 .41 .45 .41 .45 .41 .40 8 .49 .44 .41 .39 .43 .39 .43 .39 .43 .39 .38 9 .46 .42 .39 .37 .41 .37 .41 .36 .40 .36 .36 10 .44 .39 .37 .35 .39 .35 .39 .34 .38 .34 .34
LUMINAIRE INPUT WATTS = 78
Job Information Type:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504