Lightolier C4T4VM User Manual

®
HID Downlight C4T4VM
Page 1 of 4 4½" Aperture, 2pc Vertical, T4 Medium Beam
Ceiling Cutout: 5 1/8” (130 mm) Dia.
Reflector Trim Frame-In Kit
C4T4VM CLW
CLP CCDW CCDP CCZW CCZP
Specular Clear, White Painted Flange Specular Clear, Matching Flange Comfort Clear Diffuse, White Painted Flange Comfort Clear Diffuse, Matching Flange Champagne Bronze, White Painted Flange Champagne Bronze, Matching Flange
C420BT5PGJ5E1 C420T4GU65EU C420T4EU C439T4GU65EU C439T4E1 C439T4E2 C470T4E1 C470T4E2
Electronic 120V Electronic 120V/277V Electronic 120V/277V Electronic 120V/277V Electronic 120V Electronic 277V Electronic 120V Electronic 277V
Lamp (Ceramic Metal Halide)
22W Philips MiniMasterColor 20W GE ConstantColor 20W T4.5 39W Philips MiniMasterColor 39W T4.5 39W T4.5 70W T4.5 70W T4.5
Features
1. Upper Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides medium
beam optics ideal for general lighting. Also available in medium and wide beam, see C4T4VN and C4T4VW specification sheets.
2. Aper ture Cone: Provides 50° visual cut-off to lamp and lamp image; self­flange in painted white or aperture-matching polished flange. Consult factory
for other finishes.
3. Lamp Shield: High-temperature glass as required by code, captive during re-lamping. Light diffusion provides exceptionally smooth beam.
4. Socket Housing: Galvanized steel, pre-wired with G8.5 pulse rated socket. Snaps onto upper reflector for secure attachment without tools; unitized construction assures proper lamp alignment to optics for consistent performance.
5. Mounting Frame: 0.048" (18-ga.) galvanized steel. Ver tical adjustment mechanism accommodates mounting to virtually any ceiling system using mounting bars (provided, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be
preset prior to installation.
6. Mounting Ring: 0.048"(18-ga.) galvanized steel. Designed for vertical adjustment from above or below for ceilings from 0" to 2" thick. Center-line notches allow consistent alignment of multiple fixtures.
7. Mounting Bars: 0.048" (18-ga.) pre-installed, telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without
accessories.
8. Trim Retention Springs: Rust resistant springs secure reflector/housing for quick, tool-less installation.
9. Ballast / Socket Housing / Cover Assembly: Snaps onto junction box without tools for inspection and ballast replacement, accessible from below.
10. Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors. Allows inspection from below.
11. Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Electronic Ballast: 120 or 277V, 50/60 Hz., encased, high power
factor, T.H.D. <15%, thermally and transient protected, RMI/RFI complies with FCC Par t 18 non-consumer limits, shut-down circuit at end of lamp life, sound rating “A”, -5°F minimum star ting temperature, Type 1 Outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts
20W MH M156 120/277 0.21/0.10 23 39W MH M130 120/277 0.39/0.17 44 70W MH M139 120/277 0.67/0.29 78
Options and Accessories
Slope Ceiling Adapters: See Specification Sheet SCA. Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Damp Locations), CSA, I.B.E.W. For 70W, install fixtures with minimum spacing bet ween:
1. Center-to center of adjacent luminaries: 2 feet.
2. Top of luminaire to overhead building member: 1/2 inch.
3. Luminaire center to side building member: 1 foot.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0609
750
1500
1125
375
1250
2250
4500
®
HID Downlight C4T4VM
Page 2 of 4 4½" Aperture, 2pc Vertical, T4 Medium Beam
20W T4 GE CMH Lamp, Lumen Rating = 1700 LMS, Aromat 20W Electronic Ballast CL Finish Trim
CANDL EPOWER DI ST RIBUTION
ANGL E ME AN CP L UMENS 0 15 95 5 15 24 14 3
37 5
75 0
1125
150 0
** EFFI CIENCY = 66.0 %** CER TIFI ED TES T REPO RT NO. 2 322 FR, DAT E: OC T 04, 2 003 SC = . 7 COM PUTE D BY LSI P ROGR AM **T EST-L ITE* *
10 134 5 15 110 9 314 20 86 7 25 64 9 308
60 °
30 49 3 35 39 6 248 40 29 4 45 12 5 107 50 10 55 0 2 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
30 °
LUM INANC E SUMMA RY CD. / SQ. M. ANGLE M EAN C D/SQ M 4 5 172 55 5 5 39 6 5 0 7 5 0 8 5 0
ZON AL LUM ENS AND PERCE NTAGE S ZONE L UMENS % L AMP %LUM INAIR E 0- 30 7 64 44 .96 6 8.13 0-4 0 1012 5 9.5 6 90 .25 0- 60 1121 66 100 0- 90 1121 66 100 40- 90 109 6. 43 9.7 5 60- 90 0 0 0 90 -180 0 0 0 0-1 80 1121 66 100
Ceiling 80% 70% 50% 30%
Wall 70 50 3 0 10 50 10 50 10 50 10 0
RCR Z onal Cavit y Method - Effecti ve Floor C avity Ref lectanc e = 20%
10 .51 .45 .42 .39 .45 .3 9 .44 .39 .44 .39 .3 8
39W T4 Philips CMH Lamp, Lumen Rating = 3300 LMS, Aromat 39W Electronic Ballast, CL Finish Trim
CANDL EPOWER DI ST RIBUTION
A NGLE ME AN CP L UMENS 0 23 06 5 22 32 2 11
62 5
125 0
187 5
25 00
** EFFI CIENCY = 64. 3%** CER TIFI ED TES T REPO RT NO. 2 321FR , DATE : OCT 01, 200 3 SC = . 8 COM PUTE D BY LSI P ROGR AM **T EST-L ITE* *
10 2 064 15 185 6 523 20 16 01 25 13 13 616
60 °
30 109 5 35 90 2 551 40 60 9 45 24 3 216 50 20 55 3 6 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
30 °
LUM INANC E SUMMA RY CD. / SQ. M. ANGLE M EAN C D/SQ M 4 5 336 51 5 5 46 6 6 5 0 7 5 0 8 5 0
ZON AL LUM ENS AND PERCE NTAGE S ZONE L UMENS % L AMP %LUM INAIR E 0- 30 1349 4 0.9 6 3.6 0-4 0 1900 57.5 9 8 9.56 0- 60 2121 6 4.3 100 0- 90 2121 6 4.3 100 40- 90 221 6 .72 10.4 4 60- 90 0 0 0 90 -180 0 0 0 0-1 80 2121 64 .3 100
Ceiling 80% 70% 50% 30%
Wall 70 50 3 0 10 50 10 50 10 50 10 0
RCR Z onal Cavit y Method - Effecti ve Floor C avity Ref lectanc e = 20%
10 .4 8 .42 .38 .36 . 42 .36 .41 .36 .41 . 36 .35
Coef ficients of U tilization
0 .79 .79 .79 .79 .77 .7 7 .74 .74 .71 .71 .66
1 .76 .74 .73 .72 .73 .71 .70 .68 .68 .66 .63
2 .73 .70 .68 .66 .69 .6 5 .67 .64 .65 .63 .6 0
3 .70 . 66 .64 . 61 .65 .61 .64 .60 .6 2 .59 .57
4 . 67 .63 .60 .5 8 .62 .57 .61 .57 .6 0 .56 .54
5 . 64 .60 .56 .5 4 .59 .54 .58 .53 .5 7 .53 .51
6 . 62 .57 .53 .51 . 56 .51 .55 .5 0 .54 .50 .49
7 . 59 .53 .50 .4 8 .53 .47 .52 .47 .51 .47 .46
8 . 56 .51 .47 .4 5 .50 .45 .49 .44 .4 9 .44 .43
9 . 53 .48 .44 .4 2 .47 .42 .47 .42 .4 6 .42 .41
LUMIN AIRE INPUT WATTS = 23
Coef ficients of U tilization
0 .77 .77 .77 .77 .75 .7 5 .72 .72 .69 .69 .6 5
1 .74 .72 .71 .70 .71 .6 8 .68 .66 .66 .64 . 61
2 .71 . 68 .66 .6 4 .67 .63 .65 .62 .6 3 .60 .58
3 .6 8 .64 .61 .5 9 .63 .59 .62 .58 .6 0 .57 .55
4 . 65 .60 .57 .5 5 .60 .54 .58 .54 .5 7 .53 .52
5 . 62 .57 .53 .51 . 56 .51 .55 .5 0 .54 .50 .49
6 . 59 .54 .50 .4 8 .53 .48 .52 .47 .51 .47 .46
7 . 56 .51 .47 .4 5 .50 .44 .49 .44 .4 8 .44 .43
8 . 53 .47 .44 .4 2 .47 .41 .46 .41 .4 6 .41 .40
9 . 50 .45 . 41 .39 .44 .39 .4 4 .38 .43 .38 .37
LUMIN AIRE INPUT WATTS = 44
70W T4 Philips CMH Lamp, Lumen Rating = 6 400 LMS, Aromat 70W Electronic Ballast, CL Finish Trim
CANDL EPOWER DI ST RIBUTION
A NGLE ME AN CP L UMENS 0 47 07 5 45 60 43 0
1125
22 50
33 75
45 00
** EFFI CIENCY = 62.4 %** CER TIFI ED TES T REPO RT NO. 2 320 FR, DAT E: OCT 01, 20 03 SC = . 8 COM PUTE D BY LSI P ROGR AM **T EST-L ITE* *
10 418 8 15 3 667 10 32 20 3 046 25 2 445 1148
60 °
30 198 7 35 158 7 982 40 109 0 45 44 4 390 50 38 55 3 10 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
30 °
LUM INANC E SUMMA RY CD. / SQ. M. ANGLE M EAN C D/SQ M 4 5 6 1418 5 5 58 4 6 5 0 7 5 0 8 5 0
ZON AL LUM ENS AND PERCE NTAGE S
ZONE L UMENS % L AMP %LUM INAIR E 0-3 0 2 610 40 .79 65. 39 0-4 0 3 592 56 .13 8 9.97 0- 60 3 992 6 2.38 100 0- 90 3 992 6 2.38 100 40- 90 4 00 6.2 6 1 0.03 60- 90 0 0 0 90 -180 0 0 0 0-1 80 3 992 6 2.38 100
Ceiling 80% 70% 50% 30%
Wall 70 50 3 0 10 50 10 50 10 50 10 0
RCR Z onal Cavit y Method - Effecti ve Floor C avity Ref lectanc e = 20%
10 .47 .41 . 38 .36 .41 . 36 . 41 . 36 .40 .3 5 .34
Coef ficients of U tilization
0 .74 .74 .74 .74 .73 .7 3 .70 .70 .67 .67 .6 3
1 .71 .70 .69 .67 .69 .6 6 .66 .64 .64 .62 .5 9
2 .6 8 .66 .64 .6 2 .65 .61 .63 .60 . 61 .59 .56
3 .6 6 .62 .59 .5 7 .61 .57 .60 .56 .5 8 .55 .53
4 . 63 .59 .56 .5 4 .58 .53 .57 .53 .5 6 .52 .51
5 .6 0 .56 .52 .5 0 .55 .50 .54 .49 .5 3 .49 .48
6 . 57 .53 .49 . 47 .52 .47 .51 .46 .5 0 .46 .45
7 . 55 .49 .46 .4 4 .49 .44 .48 .43 .47 .43 .42
8 . 52 .47 .43 .41 . 46 .41 .46 .41 .45 .40 .39
9 . 49 .44 . 41 .38 .44 .38 .4 3 .38 .42 .38 .37
LUMIN AIRE INPUT WATTS = 78
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0609