12 4 56891011 3712
1 1/8" (29 mm) max. Ceiling Thickness
4-1/4" (108 mm) Dia.
5-1/2" (140 mm) Dia.
8" (203 mm)
Vertical Adjustment:
3/4" (25 mm) to
2 7/8" (73 mm)
5/8" (16 mm)
Top View
13-7/8" (352 mm)
20" (508 mm) to 30" (762 mm)
8-1/8" (206 mm)
15" (381 mm)
10"
(254 mm)
Calculite
®
HID Adjustable Accent C4T4A-MHT4RF
Page 1 of 2 4 1/2" Aperture, T4.5, Ceramic Metal Halide, 40° Flood
Flood Upper Reflector
Ceiling Cutout: 5 1/8” (130mm) Dia. For Complete Fixture Order: Trim Kit + Flood Reflector (MHT4RF) + Frame-In Kit. Each Sold Separately.
Trim Kit + Flood Upper Reflector Frame-In Kit Lamp
C4T4A + MHT4RF (Flood Upper Reflector)
CLW Specular Clear,White Painted Flange CLP Specular Clear,Matching Flange
CCDW Comfort Clear Diffuse, White Painted Flange CCDP Comfort Clear Diffuse, Matching Flange CCZW Champagne Bronze,White Painted Flange CCZP Champagne Bronze, Matching Flange
C4A20T4E1 Electronic 120V 20W T4.5 Ceramic MH C4A20T4E2 Electronic 277V 20W T4.5 Ceramic MH C4A39T4E1 Electronic 120V 39W T4.5 Ceramic MH C4A39T4E2 Electronic 277V 39W T4.5 Ceramic MH C4A70T4E1 Electronic 120V 70W T4.5 Ceramic MH C4A70T4E2 Electronic 277V 70W T4.5 Ceramic MH
Features
1. Flood Upper Reflector: Specular textured aluminum; provides 40° beam.
Interchangeable with 12° Spot (MHT4RS) and 25°Narrow Flood (MHT4RNF); see spec sheets C4T4A-MHT4RS and C4T4A-MHT4RNF.
2. Trim Kit : Low brightness aperture cone; anodized aluminum, self-flanged in painted white or aperture-matching polished flange. Consult factory for other finishes.
3. Lamp Shield: High-temperature glass as required by code; captive during re-lamping.
4. Trim Kit Adjustment Mechanism:Provides 35° vertical tilt, 360° horizontal rotation; lockable. Patented EZ-Aim Helical Drive System provides fast and accurate hot aiming with Philips screwdriver.
5. Socket Housing: Galvanized steel, pre-wired with G8.5 pulse rated socket. Snaps onto yoke for secure attachment without tools; unitized construction assures proper alignment of lamp to optics for consistent optical performance.
6. Frame Housing: Steel, 0.029" (22-Ga.), matte black finish. Removable cover for top re-lamping.
7. Frame Vertical Adjustment Mechanism: Accommodates mounting to vir­tually any ceiling system using pre-installed mounting bars, or 1/2" EMT tub­ing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. Final adjustment can be made from below from inside fixture.
8. Mounting Bars: Galvanized steel, 0.048" (18-ga.), pre-installed telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories.
9. Retention Springs: Rust resistant springs secure trim for quick, tool-less installation.
10.Ballast / Cover Assembly: Accessible from below and removable without tools for inspection and ballast replacement .
11.Junction Box: 0.059" (16-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90° C through branch circuit conductors. Allows inspection from below.
12.Optional Accessory Holder: Sold separately catalog # CAH4; die-formed steel, matte black finish, slide-in installation. Accepts up to two 3 3/4" dia. media.
Features (cont.)
13.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not
install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Electronic Ballast: 120V or 277V, 50/60 Hz., electronic, high power factor,
T.H.D. <15%, thermally and transient protected, RMI/RFI complies with FCC Part 18 non-consumer limits, shut-down circuit at end of lamp life, sound rating “A”, -5°F minimum starting temperature, Type 1 Outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts
20W MH M156 120/277 0.21/0.10 23 39W MH M130 120/277 0.39/0.17 44 70W MH M139 120/277 0.67/0.29 78
Options and Accessories
Chicago Plenum: Consult Factory
Labels
UL (Suitable for Damp Locations), CSA, I.B.E.W.
Job Information Type:
Job Name: Cat. No.:
Lamp(s): Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) • B0304
Calculite
®
HID Adjustable Accent C4T4A-MHT4RF
Page 2 of 2 4 1/2" Aperture, T4.5, Ceramic Metal Halide, 40° Flood
(FC) is initial footcandles at center of beam. Beam length (L) and beam width (W) are to where the candlepower is reduced to 50% of the center beam candlepower. (C) is the distance to the center of the beam.
CANDLEPOWER DISTRIBUTION 20W T4.5 – FLOOD
ANGLE WALL 0 244 5 361 10 581 15 962 20 1487 25 2181
60°
30 2520
30°
60°
30°
60°
30°
35 2084 40 1382 45 859 50 498 55 221 60 79 65 18 70 1 75 1 80 1 85 0 90 0
ANGLE WALL 0 446 5 660 10 1052 15 1762 20 2543 25 3163 30 3439 35 3133 40 2389 45 1670 50 1191 55 614 60 226 65 59 70 3 75 0 80 0 85 0 90 0
ANGLE WALL 0 1179 5 1830 10 2840 15 4083 20 5226 25 6268 30 6667 35 6027 40 4505 45 3236 50 1985 55 858 60 287 65 55 70 1 75 1 80 1 85 1 90 1
1,250
1,875
2,500
CANDLEPOWER DISTRIBUTION 39W T4.5 – FLOOD REFLECTOR
1,750
2,625
3,500
CANDLEPOWER DISTRIBUTION 70W T4.5 – FLOOD REFLECTOR
3,250
4,875
6,500
AIMED 30° TOWARD WALL T4 20W G.E. METAL HALIDE LAMP
LUMEN RATING = 1700 LMS. AROMAT 20W ELECTRONIC BALLAST
CBCP = 2,520 cd BEAM ANGLE = 22°
DATE: OCT 31, 2003 CERTIFIED TEST REPORT NO. 2353FR
COMPUTED BY LSI PROGRAM **TEST-LITE**
AIMED 30° TOWARD WALL T4 39W PHILIPS METAL HALIDE LAMP
LUMEN RATING = 3300 LMS. AROMAT 3,439 cd BEAM ANGLE = 30° AROMAT 39W ELECTRONIC BALLAST
DATE: OCT 30, 2003 CERTIFIED TEST REPORT NO. 2348FR
COMPUTED BY LSI PROGRAM **TEST-LITE**
AIMED 30° TOWARD WALL T4 70W PHILIPS METAL HALIDE LAMP
LUMEN RATING = 6400 LMS. AROMAT 6,667 cd BEAM ANGLE = 33° AROMAT 70W ELECTRONIC BALLAST
DATE: OCT 26, 2003 CERTIFIED TEST REPORT NO. 2347FR
COMPUTED BY LSI PROGRAM **TEST-LITE**
30° Aiming Angle
Horizontal Surface
DC FCL W
6' 3.5' 45 3.1' 2.7' 8' 4.6' 26 4.2' 3.6' 10' 5.8' 16 5.2' 4.5' 12' 6.9' 11 6.3' 5.4' 15' 8.7' 7 7.9' 6.7'
30° Aiming Angle
Horizontal Surface
DC FCL W
6' 3.5' 62 4.4' 3.7' 8' 4.6' 35 5.9' 5.0' 10' 5.8' 22 7.3' 6.2' 12' 6.9' 16 8.8' 7.4' 15' 8.7' 10 11.0' 9.3'
30° Aiming Angle
Horizontal Surface
DC FCL W
8' 4.6' 68 6.5' 5.5' 10' 5.8' 43 8.1' 6.8' 12' 6.9' 30 9.8' 8.2' 15' 8.7' 19 12.2' 10.3' 20' 11.5' 11 16.3' 13.7'
30° Aiming Angle
Vertical Surface
DC FCL W
2' 3.5' 79 3.5' 1.6' 3' 5.2' 35 5.3' 2.3' 4' 6.9' 20 7.0' 3.1' 6' 10.4' 9 10.5' 4.7' 8' 13.9' 5 14.0' 6.2'
30° Aiming Angle
Vertical Surface
DC FCL W
2' 3.5' 107 5.5' 2.1' 3' 5.2' 48 8.2' 3.2' 4' 6.9' 27 10.9' 4.3' 6' 10.4' 12 16.4' 6.4' 8' 13.9' 7 21.9' 8.6'
30° Aiming Angle
Vertical Surface
DC FCL W
3' 5.2' 93 9.6' 3.6' 4' 6.9' 52 12.9' 4.7' 6' 10.4' 23 19.3' 7.1' 8' 13.9' 13 25.7' 9.5' 12' 20.8' 6 38.6' 14.2'
Job Information Type:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504