Calculite
15"
7"
8"
9.66"
9.66"
5.45"
Side Views
Frame-In Kit: C420MREU
Top View
®
HID Downlight C4MRD
Page 1 of 2 4 1/2" Aperture (1) 20W CMH MR16
Ceiling Cutout: 5 1/16 " (12 9 mm) Dia. Ceiling Thickness: 1 1/8” Max
Reflector Trim Frame-In Kit Lamp
Finish White Flange Polished Flange
Comfort Clear Diffuse
Comfort Clear
Champagne Bronze
Features
1. Trim Kit Aperture Cone: 50° visual cut-off to lamp and lamp image. Low
brightness, 0.040” aluminum, anodized; keyed to lamp support assembly
for true aiming of lamp to prevent incorrect installation of cone. Hinged
and snaps on for easy tool-less installation.
2. Lamp Support: Die-form aluminum with knurled surface for easy gripping
during relamping. Spring tension clips hold lamp and lens and allow fast
snap-in, snap-out relamping. Matte black finish.
NOTE: HID lampholder ship with the frame. Discard the incandescent
lampholder that ships standard with the trims.
3. Horizontal Adjustment Mechanism: Die-form steel ring, matte black
finish. Provides 360° horizontal stop, lockable.
4. Frame Vertical Adjustment Mechanism: Accommodates mounting
to virtually any ceiling system using pre-installed mounting bars, or ½”
EMT tubing (by others). Single locking feature secures all adjustments.
Alignment holes and markings allow fixture to be pre-set prior to
installation. Final adjustment can be made from below inside fixture.
5. Mounting Bars: Galvanized steel, 0.048”; pre-installed telescoping bars
extend to 30” long and lock securely into position. Built-in locking tabs
provide positive attachment to common T-bars systems. Self-centering
feature simplified installation in 24” O.C. grid systems. Attaches to steel or
wood joists without accessories
6. Socket Harness: Twist and lock base. 5kV (600V) pulse rated PPS, black
T240 body socket with nickel-plated contacts. 18 AWG silicone leads with
fiberglass outer sleeve
C4MRD CCDW C4MRD CCDP
C4MRD CCLW C4MRD CCLP
C4MRD CCZW C4MRD CCZP
C420MREU – Electronic 120/277V Non-IC (1) 20W MR16 CMH
GX10 Base
Options and Accessories
Accepts one accessory
Labels
U.L (Suitable for Damp Locations)
Teflon® is a registered trademark of E.I. DuPont.
US Patent No. 5,9 57,573. Other US and Foreign Patents Pending.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 Genlyte Group LLC • A1007
Calculite
500
1000
1500
2000
0°
30°
60°
90°
750
1500
2250
3000
0°
30°
60°
90°
1750
3500
5250
7000
0°
30°
60°
90°
®
HID Downlight C4MRD
Page 2 of 2 4 1/2" Aperture (1) 20W CMH MR16
C4MRDCCLW, 20W G.E. HID SPOT, 12° GX10 BASE
LUMEN R ATING = 1000 LMS.
SC = . 3
TEST R EPORT NO. 3 405FR
CANDLEPOWER SUMMARY
Angle Mean CP Lumens
0 6 795
5 5107 457
10 2136
15 803 29 3
20 386
25 207 10 8
30 134
35 52 42
40 30
45 16 12
50 0
55 0 0
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS %LAMP %LUMINAIRE
0- 30 8 57 85.75 94.0 6
0- 40 8 99 89.97 98.6 9
0- 60 911 91.16 100.00
0- 90 911 91.16 100.00
40 -90 11 1.19 1.31
60 -90 0 .00 .00
90-180 0 .00 .0 0
0 -180 911 91.16 10 0.00
LUMINANCE SUMMARY
ANGLE MEAN CD/SQ M
45 2475
55 0
65 0
75 0
85 0
Tested according to IES proc edures.
Test dis tance exc eeds five times the g reatest l uminous ope ning of lumina ire.
C4MRDCCLW, 20W G.E. HID FLOOD, 25° GX10 BASE
LUMEN R ATING = 1000 LMS.
SC = .4
TEST R EPORT NO. 33 92FR
CANDLEPOWER SUMMARY
Angle Mean CP Lumens
0 32 80
5 28 96 267
10 2105
15 1316 386
20 715
25 342 184
30 187
35 92 67
40 53
45 30 22
50 0
55 0 0
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS %LAMP %LUMINAIRE
0- 30 8 36 83.67 90.41
0- 40 9 03 90.3 3 97.61
0- 60 925 9 2.54 100.0 0
0- 90 925 9 2.54 100.0 0
40 -90 2 2 2.21 2.39
60 -90 0 .00 .00
90-180 0 .00 .0 0
0 -180 9 25 92.5 4 10 0.00
LUMINANCE SUMMARY
ANGLE MEAN CD/SQ M
45 4709
55 0
65 0
75 0
85 0
Tested according to IES proc edures.
Test dis tance exc eeds five times the g reatest l uminous ope ning of lumina ire.
** EFFIC IENCY = 91.2% **
** EFFIC IENCY = 92.5% **
COEFFICIENTS OF UTILIZATION
ZONAL CAVITY METHOD
CC 80 70 50 30 10
WALL 70 50 30 10 70 50 30 10 50 3 0 10 50 30 10 50 3 0 10 0
RCR
0 1. 09 1. 09 1.09 1.09 1.06 1.06 1.06 1.06 1.01 1.01 1.01 .97 .97 . 97 .93 .93 .9 3 .91
1 1.0 6 1.04 1.03 1.02 1.04 1.03 1.01 1.00 .99 .9 8 .97 .95 .95 .94 .9 2 .92 .91 .9 0
2 1.03 1.01 .98 .9 6 1.01 . 99 .9 7 .95 .96 . 95 .9 3 .94 .93 .92 .91 .91 .90 .88
3 1.01 .97 .9 5 .93 .99 . 96 .9 4 .92 .94 . 92 . 91 .92 .91 . 90 .91 .89 . 88 .87
4 .99 .9 5 .92 .9 0 .98 .9 4 .92 .9 0 .92 .90 . 89 .91 .89 .88 .89 .88 .87 .86
5 .97 .9 3 .90 .8 8 .95 .9 2 .89 .8 7 .90 .88 . 87 .89 .87 .86 .88 .87 .85 .84
6 .95 . 91 .88 .8 6 .94 .9 0 .87 .8 5 .89 .87 . 85 .88 .86 .84 .87 .85 .84 .83
7 .93 .8 9 .86 . 84 .92 .8 8 .86 .8 3 .87 .85 . 83 .86 .84 .83 .86 .84 .82 .8 2
8 .92 .8 7 .84 . 82 .91 .8 6 .84 .8 2 .86 .83 . 82 .85 .83 .81 .84 .83 .81 .80
9 .90 .8 5 .83 .81 . 89 .8 5 .83 .81 . 84 .8 2 .80 .8 4 .82 .80 .8 3 .81 .80 .79
10 .88 . 84 . 81 .79 .88 . 84 . 81 .79 .83 .81 .79 .8 2 .80 .79 .8 2 .80 .79 . 78
CC 80 70 50 30 10
WALL 70 50 30 10 70 50 30 10 5 0 30 10 50 3 0 10 50 30 10 0
RCR
0 1.10 1.10 1.10 1.10 1.08 1.08 1.08 1.08 1.03 1.03 1.03 .98 .98 .98 .94 .94 .94 .93
1 1.07 1.05 1.04 1.02 1.05 1.04 1.02 1.01 1.00 .99 . 98 .96 .95 .95 .93 .93 .92 .91
2 1.04 1.01 .99 .9 6 1.0 2 .99 . 97 .95 .9 6 .95 . 93 .94 .93 .91 .92 .91 .90 .88
3 1.01 .97 .9 4 .92 1. 00 .9 6 .94 . 92 .94 .9 2 .90 .92 .90 .89 .90 .89 .87 .86
4 .98 .9 4 .91 .8 9 .97 .9 3 .91 .8 8 .92 .89 . 87 .90 .88 .86 .88 .87 .85 .84
5 .96 . 91 .88 .8 5 .95 .9 0 .87 .8 5 .89 .86 . 84 .87 .85 .83 .86 .85 .83 .82
6 .94 .8 9 .85 . 83 .93 .8 8 .85 .8 3 .87 .84 . 82 .86 .83 .82 .85 .83 .81 .80
7 .91 .8 6 .83 .8 0 .90 .8 5 .82 .8 0 .84 .82 . 80 .83 .81 .79 .83 .80 .79 .7 8
8 .89 .8 3 .80 .78 . 88 .8 3 .80 .77 .82 .79 .77 .81 .79 .77 .81 .78 .77 .76
9 .87 . 81 .78 .76 . 86 . 81 .78 .76 . 80 .7 7 .75 .8 0 .77 .75 .7 9 .76 .75 .74
10 .85 .79 .76 .73 .84 .7 9 .76 .73 .78 .75 .73 .78 .75 .73 .77 .75 .73 .72
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
deter mined in acco rdance wit h current IE S published pr ocedures
deter mined in acco rdance wit h current IE S published pr ocedures
CU VALUE GR EATER THAN 1.0 0
LUMIN AIRE INPUT WATT S = 26.0
COEFFICIENTS OF UTILIZATION
ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
CU VALUE GR EATER THAN 1.0 0
LUMIN AIRE INPUT WATT S = 26.0
C4MRDCCLW, 20W G.E. HID FLOOD, 40° GX10 BASE
LUMEN R ATING = 1000 LMS.
SC = . 6
TEST R EPORT NO. 33 91FR
CANDLEPOWER SUMMARY
Angle Mean CP Lumens
0 2247
5 19 83 187
10 1629
15 13 00 366
20 934
25 504 2 55
30 261
35 120 8 8
40 62
45 37 27
50 5
55 1 2
60 1
65 1 1
70 0
75 0 0
80 0
85 0 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS %LAMP %LUMINAIRE
0- 30 8 07 80.79 87.15
0- 40 8 96 89.6 3 96. 69
0- 60 925 9 2.56 9 9.85
0- 90 926 9 2.70 100.0 0
40 -90 3 0 3.07 3.31
60 -90 1 .14 .15
90-180 0 .00 .0 0
0 -180 9 26 92.70 100.0 0
** EFFIC IENCY = 92.7% **
LUMINANCE SUMMARY
ANGLE MEAN CD/SQ M
45 573 7
55 2 60
65 211
75 157
85 2 00
Tested according to IES proc edures.
Test dis tance exc eeds five times the g reatest l uminous ope ning of lumina ire.
CC 80 70 50 30 10
WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 5 0 30 10 0
RCR
0 1.10 1.10 1.10 1.10 1.08 1.08 1.08 1.08 1.03 1.03 1.03 .99 .99 .99 .95 .95 .95 .93
1 1.07 1.05 1.03 1.02 1.05 1.03 1.02 1.00 .9 9 .98 .9 7 .96 .95 .94 .93 .92 .92 .90
2 1.03 1.00 .98 .9 5 1.0 2 .99 .9 6 .9 4 . 96 .9 4 .92 .9 3 .92 .91 . 91 .90 .89 .8 7
3 1.0 0 .9 6 .93 . 91 .99 .95 . 92 .9 0 .93 .91 . 89 .91 .89 .87 .89 .88 .86 .85
4 .97 .9 3 .89 . 87 .96 .9 2 .89 .8 6 .90 .87 . 85 .88 .86 .84 .87 .85 .83 .82
5 .94 .8 9 .85 . 83 .93 .8 8 .85 .8 2 .87 .84 . 82 .86 .83 .81 .84 .82 .80 .79
6 .92 .8 6 .83 .8 0 .91 .8 6 .82 .8 0 .85 .82 .79 .83 .81 .79 .82 .80 .78 .77
7 .89 .8 3 .79 .77 . 88 .8 3 .79 .76 .82 .78 .76 .81 .78 .76 .80 .77 .75 .75
8 .87 .8 0 .77 .74 . 86 .8 0 .76 .74 .79 .76 .74 .78 .75 .73 .77 .75 .73 .72
9 .84 . 78 .74 .71 . 83 .7 7 .74 .71 .76 .73 .71 .76 .73 .71 .75 .72 .70 .70
10 .81 .75 .72 . 69 .81 .75 .72 .6 9 .74 .71 . 69 .74 .71 .68 .73 .70 . 68 .67
deter mined in acco rdance wit h current IE S published pr ocedures
COEFFICIENTS OF UTILIZATION
ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
CU VALUE GR EATER THAN 1.0 0
LUMIN AIRE INPUT WATT S = 26.0
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 Genlyte Group LLC • A1007