Lightolier C4LVE1RM User Manual

Calculite
4310 61
52 87 9
5 1/2"
1/2" - 2" Ceiling Thk.
4 1/2" Dia.
7"
8 1/2"
11 5/8"
Top View
®
Evolution Downlighting C4LVE1RM
Page 1 of 1 4 1/2" Aperture Non-IC Low Voltage Remodeler Frame-In Kit
Ceiling Cutout: 5 1/16" (129 mm) Dia.
Frame-In Kit Reflector Trim
C4LVE1RM
Open
Downlight
C4MRD
20W-50W MR16 (12V)
Adjustable
Accent
C4MRA
20W-50W MR16 (12V)
Adjustable
Accent
C4ARA
20W-50W AR70 (12V)
Adjustable 2” Aperture
C4MR2
20W-50W MR16 (12V)
Adjustable 1 1/4” Pinhole
C4MRP
20W-50W MR16 (12V)
Lensed
Wall Washer
C4MRL
20W-50W MR16 (12V)
Glasslite Downlight
C4MRGD
20W-50W MR16 (12V)
Glasslyte Adjustable
C4MRGA
20W-50W MR16 (12V)
Lensed Adjustable
C4MRW
20W-50W MR16 (12V)
Note: Magnetic transformers may produce audible sound when used with dimmers, which may be objectionable in acoustically critical areas.
Features
1. Housing: Hydroformed aluminum, 0.04” (18 ga.). Removable for access to J-Box and transformer.
2. Mounting Frame: Die-formed steel, 0.03” (22 ga.) galvanized steel.
Accommodates existing ceilings up to 2” thick.
3. Locking Clips: Quick-Lock clips provide ratcheting coarse adjustment for
ceiling thickness from 1/2” to 2” thick.
4. Fine Adjustment Screws: Provide pressure to clamp the ceiling material
for secure mounting.
5. Retaining Springs: Precision-tooled steel springs secure reflector trim to
housing for quick, tool-less installation.
6. Quick Electrical Connector: Keyed to accept plug from reflector trim.
7. Junction Box: 0.03” (22 ga.) galvanized steel. UL listed for 90°C supply
connection. Integral cable clamps permit attachment of #14 or #12 ga. non­metallic cable without tools or additional connectors.
8. Transformer: Electronic, 120V 60 Hz, primary, nominal 12V secondary,
short circuit and thermal protection, high power factor, THD<10%, dimmable, FCC approved, quiet operation.
9. Thermal Protector: Meets NEC and UL requirements. Insulation must be
kept 3” away from fixture sides and wiring compartments and must not be placed above fixture in a manner which will entrap heat.
10. Reflector Trim: Compatible reflector trims are listed above. See separate
reflector trim specification sheets for complete catalog numbers, finish,
and details.
Notes:
Vertical aiming for MR16 adjustable trims is 35° max. when used with remodeler. Vertical aiming for AR70 adjustable trims is 25° max. when used with remodeler.
Electrical/Dimming
Dimming controls: Use with dimmers specially designed for use with electronic transformers, like Lightolier Sunrise™, Multiset™, Momentum QE series. For addi­tional information, see Lightolier Controls Catalog or contact Lightolier Controls at 800-526-2731 or visit website at w ww.lolcontrols.com.
Labels
CULUS Listed (suitable for damp locations), I.B.E.W.
US Patent Pending.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s): Notes:
Lightolier is a Philips group brand
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • B0708
Loading...