Lightolier AGM User Manual

Lighting Systems Agili-T Pendant Direct/Indirect AGM
Page 1 of 4 1 lamp T5 UP, 2 lamp T5 DOWN per 4’ section
1-13/16”
46mm
6-15/16”
176mm
Ordering information
48” (1219mm) or 96” (2438mm)
52-3/16” (1326mm) or 100-3/16” (2545mm)
AG
Family
AG: Agili-T
M
Type
M: Direct-Indirect with Independent Compartments (Multiple Optics) & Louvers
4
Luminaire
Length
4: 4’
8: 8’
Note : Luminaire comes without end-caps
P
Mounting
P: Pendant
(Compatible with Wall & Furniture Mounting Systems)
GR
Housing Finish
GR: Titanium
WH: White
DS: Double-circuit
DN: Double-
circuit Network­Ready
DI: Single-feed Double-circuit Network
DG: Group-feed Double-circuit Network
Features
• Direct-Indirect 66.2% efficient (54% up, 46% down) using T5 lamp technology (3xF28T5).
• Separate optics for maximum control options.
• Ultra-Light construction (4’ luminaire less than 12 lb / 5.5 kg) favors mobility, adds installation and remodeling convenience.
• Wide indirect distribution for uniform ceiling luminance.
• Trouble-free luminaire-to-luminaire connectability and luminaire-to-end-cap installation. Special die-cast aluminum joining mechanism (patent 6,769,784) providing continuous
• trouble-free, simultaneous mechanical and electrical connections (plus network connections on Agili-T Network version), as well as no-hassle end-cap installation.
• Built-in network connectors and wiring (Agili-T Network).
Construction
• One-piece aluminum extrusion
• Highly resistant composite plastic end-cap
• Optic made of highly reflective matte aluminum
• Unique contoured louver design with integral light stop
Fixture lenghts & mounting locations
2-3/32” End-cap
48” (1219mm) 96” (2438mm)
2-3/32” End-cap
DS
Wiring
3
Lamp Qty
in a cross
section
3
(1 lamp up, 2 lamps down)
28
Lamp
28: 28W T5
54: 54W
T5HO
UNV
Voltage
120: 120V
277: 277V
347: 347V
UNV:
Universal Voltage 120/277V
PG
Ballast
DW: iGEN DALI Adressable
T5/T5HO with Network-2 MultiSense Integral Motion Sensor (120 or 277V only)
DA: iGEN DALI Adressable T5/T5HO (UNV only)
PG: Electronic Program Start T5/T5HO
Electrical
• AGM with PG ballast code comes with one ballast (for upper compartment) and one 2-lamp ballast (for lower compartment) per 4’ of luminaire.
• Standard product offering (DS and DN version, 120V and 277V only) includes continuous 2-circuit wiring, one circuit for the upper compartment (if applicable) and one circuit for the lower compartment (if applicable). Single and double compartment luminaires can be mixed.
• DA and DW available with Agili-T Network only.
• Integrated quick connectors for power and network cable (Agili-T Network only) and auto plug-in connections between luminaires.
• 18-gauge wire, maximum 10A per circuit.
Mounting
• Suspension points on module: every 4’ (4’ luminaire) or every 8’ (8’ luminaire.)
• Fast installation using mounting clip for Standard T-bar and Slim T-bar or for Slot T-bar (see last page).
Finish
• Seamless color and texture finish between luminaire and end-caps.
Available with textured (white or titanium) high resistant powder-based coating.
Options and accessories
• Emergency circuiting
Labels
Options
48” Luminaire 96” Luminaire
Pendants measure exactly 48” or 96” (plus end-caps) to facilitate installation.
** If electrical junction box is needed to connect emergency wiring, order AGEB, AGES or AGEO. *** 18-gauge wire. Maximum of 10A per breaker. 2 circuits using 2 breakers with common neutral.
For maximum flexibility, DS & DN wiring options include continuous 2-circuit wiring: one circuit
for upper compartment, one circuit for lower compartment (single and double compartment luminaires can be mixed).
End-cap Row Joiners:
L: Order 1 Power Feed Suspension Kit and 1 Suspension Kit per luminaire + 1, T: Order 2 Power Feed Suspension Kit and 1 Suspension Kit per luminaire + 1, X: Order 2 Power Feed Suspension Kit and 1 Suspension Kit per luminaire + 2
Listed as a standard electrical box for through-branch wiring.
††
Consult your Lightolier representative for other adapter shapes.
LIGHTOLIER
A GENLYTE COMPANY
www.lightolier.com TECHNICAL INFORMATION: (978) 657-7600 - (978) 658-0595 631 AIRPORT ROAD, FALL RIVER, MA 02720 - (508) 679-8131
Job Information Type:
Job Name: Cat. No.:
Lamp(s): Notes:
CANLYTE www.canlyte.com 525 EDUCATION ROAD, CORNWALL, ONTARIO, CANADA K6H 6C7 - (613) 938-6221 WE RESERVE THE RIGHT TO CHANGE DETAILS OF DESIGN, MATERIALS AND FINISH © 2007 GENLYTE GROUP LLC (LIGHTOLIER DIVISION) AGM-1
Lighting Systems Agili-T Pendant Direct/Indirect AGM
Page 2 of 4 1 lamp T5 UP, 2 lamp T5 DOWN per 4’ section
Separate Optics
AGM features separate optics enabling the independent lighting control of upper and lower AGM compartments, whether the luminaire is installed individually or in a row.
INDIVIDUAL CONTROL
• One circuit for AGM upper compartment controls 1 ballast and 1 T5 lamp for indirect lighting ( per 4’ of luminaire).
• One circuit for AGM lower compartment controls 1 ballast and 2 T5 lamps for direct lighting ( per 4’ of luminaire).
• Two ballasts allow independant control of compartments (e.g. uniform ceiling luminance and no direct light).
• Separate dimming of compartments available with Agili-T Network version.
CONTINUOUS-ROW CONTROL
All Agili-T luminaires are available with double-circuit wiring (suffixes DS and DN). When AGM is installed in a row with other Agili-T luminaires, the two continuous-wired circuits maintain the integrity of separate controls for the AGM luminaire.
• Rows combining AGM and AGU useful for applications requiring specially located direct light for task illumination.
• When the upper-compartment circuit is switched on, upper-compartment lighting for the entire row is activated.
• When the lower-compartment circuit is switched on, lower-compartment lighting for the entire row is activated.
• Mixed rows including different models of Agili-T Network enable precise control of each circuit in each luminaire.
Agili-T Accessories
Suspension Kit (Patent # 6,634,772)
AG
AC
24 X G
End-cap Row Joiners
(Patent # 6,568,830)
AG CG L
Upper compartment
Lower compartment
DS
Family
AG: Agili-T
Typ e
AC: Aircraft
cable, canopy and joiner mechanism
Power Feed Suspension Kit
Suspension
Length
24: Adjustable
6- 24”
36: Adjustable 6- 36”
*
(Patent # 6,634,772)
End-cap
Color
X: N/A
Canopy Color
G: Titanium W: White
AG EC 24 G G UNV
Family
AG: Agili-T
Typ e
EC: End-caps (2),
aircraft cable, canopy, joiner mechanism
Suspension
Length
24: Adjustable
6- 24”
36: Adjustable 6- 36”
G: Titanium W: White
End-cap
Color
Canopy Color
G: Titanium W: White
Voltage
347: 347V Cable
UNV: 120/277V
Ordering instructions
1. Choose Agili-T luminaire.
2. Choose Power Feed Suspension Kit. One Kit per individual luminaire or one
per row at row extremity (18-gauge wire feed, maximum of 10A per circuit).
3. Choose Suspension Kit. One per luminaire.
Family
AG: Agili-T
CG: Titanium CW: White
4-1/8"
“L” shape
Type
4-1/8"
Shape
L: 90° “L” shape, 2 rows T: “T” shape, 3 rows X: “X” shape, 4 rows
“T” shape
Wiring
DS: Double-circuit DN: Double-circuit Network
Mounting Elements (T-bar Clip Patent # 6,637,710)
DS
t
Wiring
DS: Double-circuit
DN: Double-circuit
Network-Ready
4. Choose Mounting Elements. One per Suspension Kit.
5. Choose Mounting Elements With Junction Box. One per Power Feed Suspension Kit, as needed.
AGTB One-piece T-bar wraparound clip for standard T or narrow T AGSB One-piece T-bar wraparound clip for slot T (consult your Lightolier representative for availability) AGOG Off-grid holding bar
AGEB
One-piece T-bar wraparound clip for standard T or narrow T
with integrated easy-access Lightolier electrical box
AGES
One-piece T-bar wraparound clip for slot T with integrated easy-access Lightolier electrical box (consult your Lightolier representative for availability)
AGEO
Off-grid holding bar with integrated easy-access Lightolier electrical box
t
“X” shape
** If electrical junction box is needed to connect emergency wiring, order AGEB, AGES or AGEO. *** 18-gauge wire. Maximum of 10A per breaker. 2 circuits using 2 breakers with common neutral.
For maximum flexibility, DS & DN wiring options include continuous 2-circuit wiring: one circuit for upper compartment, one circuit for lower compartment (single and double compartment
luminaires can be mixed).
Listed as a standard electrical box for through-branch wiring.
††
Consult your Lightolier representative for other adapter shapes.
To order the latest network-type ballast for the Agili-T Network luminaire, consult your Lightolier representative for availablility.
Lighting Systems Agili-T Pendant Direct/Indirect AGM
Page 3 of 4 1 lamp T5 UP, 2 lamp T5 DOWN per 4’ section
Performance Upper Compartment
CANDLEPOWER CURVE
REPORT NO: LSC8531 1 X 28W T5 UPPER OPTIC
Efficiency: 90.8%. Indirect Peak at: 120°.
Indirect Maximum candela: 1067 cd
ZONE DEG 0 22,5 45 67,5 90
180 322 322 322 322 322 175 317 315 314 322 315 170 317 315 315 324 308 165 312 297 310 316 321 160 295 302 307 317 311 155 289 279 298 323 316 150 265 269 305 314 324 145 251 260 293 331 352 140 229 241 291 370 395 135 207 230 304 452 515 130 176 214 345 621 708 125 156 196 464 777 881 120 133 199 585 943 1067 115 101 222 709 958 962 110 71 272 699 731 754 105 48 319 530 640 664 100 30 264 387 403 418 95 8 138 179 197 195 90 0 0 0 0 0
CANDLEPOWER
ZONAL CAVITY METHOD • EFFECTIVE FLOOR CAVITY REFLECTANCE = .20 80 70 50
Wall reflectance 70 50 30 70 70 50 30 10 50 30 10 0 .86 .86 .86 .86 .74 .74 .74 .74 .50 .50 .50 1 .79 .75 .72 .69 .67 .64 .62 .58 .44 .42 .41 2 .71 .65 .60 .56 .61 .56 .52 .48 .38 .36 .34 3 .65 .57 .51 .47 .55 .49 .44 .40 .34 .31 .28 4 .59 .50 .44 .39 .50 .43 .38 .34 .30 .26 .24 5 .54 .44 .38 .33 .46 .38 .33 .29 .26 .23 .20 6 .50 .40 .33 .28 .42 .34 .29 .25 .24 .20 .17
ROOM CAVITY RATIO
7 .46 .36 .29 .24 .39 .31 .25 .21 .21 .18 .15 8 .42 .32 .25 .21 .36 .27 .22 .18 .19 .16 .13 9 .39 .29 .23 .18 .33 .25 .20 .16 .17 .14 .11 10 .36 .26 .20 .16 .31 .23 .18 .14 .16 .12 .10
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
LUMINAIRE INPUT WATTS = 31.8
DISTRIBUTION
ZONE LUMENS %LAMP % LUMINAIRE 180-150 258 9.90 10.91 180-140 445 17.07 18.79 180-120 1154 44.22 48.69 180-90 2370 90.82 100.00 140-90 1925 73.76 81.21 120-90 1216 46.60 51.31 0-90 0 .00 .00 0-180 2370 90.82 100.00
COEFFICIENTS OF UTILIZATION
Performance Lower Compartment
CANDLEPOWER CURVE CANDLEPOWER
ZONE DEG 0 22,5 45 67,5 90
0 1685 1685 1685 1685 1685 5 1677 1675 1682 1688 1686 10 1635 1628 1663 1679 1682 15 1570 1580 1611 1628 1617 20 1495 1494 1519 1503 1490 25 1399 1407 1377 1367 1355 30 1286 1285 1237 1200 1184 35 1155 1145 1072 1022 970 40 1011 976 887 811 777 45 858 806 689 624 594 50 664 634 506 464 446 55 421 421 346 312 275 60 145 158 186 150 104 65 5 18 60 46 11 70 0 0 10 0 0 75 0 0 0 0 0 80 0 0 0 0 0 85 0 0 0 0 0 90 0 0 0 0 0
REPORT NO: LSC8447 2 X 28W T5 LOWER OPTIC
Efficiency: 54%.
Candela at Nadir: 1685 cd
ZONAL CAVITY METHOD • EFFECTIVE FLOOR CAVITY REFLECTANCE = .20 80 70 50
Wall reflectance 70 50 30 10 70 50 30 10 50 30 10 0 .64 .64 .64 .64 .63 .63 .63 .63 .60 .60 .60 1 .61 .59 .58 .56 .60 .58 .57 .55 .56 .55 .54 2 .57 .54 .52 .50 .56 .53 .51 .49 .51 .50 .48 3 .54 .50 .46 .44 .52 .49 .46 .44 .47 .45 .43 4 .50 .45 .42 .39 .49 .45 .42 .39 .43 .41 .38 5 .47 .41 .38 .35 .46 .41 .37 .35 .40 .37 .34 6 .44 .38 .34 .31 .43 .37 .34 .31 .36 .33 .31
ROOM CAVITY RATIO
7 .41 .35 .31 .28 .40 .34 .30 .28 .33 .30 .28 8 .38 .31 .27 .25 .37 .31 .27 .25 .30 .27 .25 9 .35 .29 .25 .22 .34 .28 .24 .22 .28 .24 .22 10 .32 .26 .22 .20 .32 .26 .22 .20 .25 .22 .19
DETERMINED IN ACCORDANCE WITH CURRENTIES PUBLISHED PROCEDURES
LUMINAIRE INPUT WATTS = 62.9
DISTRIBUTION
ZONE LUMENS %LAMP % LUMINAIRE 0-30 1243 23.82 44.08 0-40 1910 36.59 67.71 0-60 2770 53.09 98.24 0-90 2821 54.04 100.00 40-90 911 17.45 32.29 60-90 50 .95 1.76 90-180 0 .00 .00 0-180 2821 54.04 100.00
COEFFICIENTS OF UTILIZATION
Lighting Systems Agili-T Pendant Direct/Indirect AGM
Page 4 of 4 1 lamp T5 UP, 2 lamp T5 DOWN per 4’ section
Performance
CANDLEPOWER CURVE
DISTRIBUTION
ZONE LUMENS %LAMP % LUMINAIRE 0-30 1243 15.88 23.97 0-40 1909 24.39 36.81 0-60 2769 35.37 53.40 0-90 2818 36.00 54.35 40-90 909 11.62 17.53 60-90 49 .63 .95 90-180 2367 30.24 45.65 0-180 5186 66.24 100.00
REPORT NO: LSC8534 CAT. NO: AGM4PGRDS328UNVPG
2 x 28W T5 down and 1 x 28W T5 up at 2610 lumens. Efficiency: 66.2%. Indirect Maximum candela: 1067 cd Indirect Peak at: 120°. Candela at Nadir: 1685 cd
CANDLEPOWER
ZONE DEG 0 22,5 45 67,5 90
0 1685 1685 1685 1685 1685 5 1676 1674 1682 1688 1685 15 1570 1580 1611 1628 1617 25 1398 1407 1376 1366 1354 35 1154 1144 1071 1021 977 45 857 806 689 623 593 55 420 421 345 311 275 65 5 18 59 45 10 75 0 0 0 0 0 85 0 0 0 0 0 90 0 0 0 0 0 95 7 137 178 196 194 105 47 319 530 640 663 115 101 221 709 958 962 125 155 195 464 777 880 135 206 229 304 452 515 145 250 260 293 331 351 155 289 279 297 323 315 165 312 297 310 315 320 175 316 315 314 321 315 180 322 322 322 322 322
COEFFICIENTS OF UTILIZATION
80 70 50 30 10 0
70 50 30 70 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 .72 .72 .72 .72 .66 .66 .66 .66 .57 .57 .57 .48 .48 .48 .40 .40 .40 .36 1 .67 .64 .62 .60 .62 .60 .58 .56 .52 .50 .49 .44 .43 .43 .37 .37 .36 .33 2 .62 .58 .55 .52 .58 .54 .51 .49 .47 .45 .43 .41 .39 .38 .35 .34 .33 .30 3 .57 .52 .48 .45 .53 .49 .45 .43 .43 .40 .38 .37 .35 .34 .32 .31 .30 .27 4 .53 .47 .43 .39 .50 .44 .40 .37 .39 .36 .34 .34 .32 .30 .29 .28 .27 .24 5 .49 .42 .38 .34 .46 .40 .36 .33 .35 .32 .30 .31 .28 .27 .27 .25 .24 .22 6 .46 .38 .34 .30 .43 .36 .32 .29 .32 .29 .26 .28 .26 .24 .25 .23 .21 .20
ROOM CAVITY RATIO
7 .42 .35 .30 .27 .39 .33 .29 .26 .29 .26 .23 .26 .23 .21 .23 .21 .19 .18 8 .39 .32 .27 .24 .37 .30 .26 .23 .27 .23 .21 .24 .21 .19 .21 .19 .17 .16 9 .36 .29 .24 .21 .34 .27 .23 .20 .24 .21 .18 .21 .19 .17 .19 .17 .15 .14 10 .34 .26 .21 .18 .31 .25 .21 .18 .22 .19 .16 .20 .17 .15 .17 .15 .13 .12
ZONAL CAVITY METHOD • EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
Wall reflectance
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
LUMINAIRE INPUT WATTS = 94.7
Job Information Type:
LIGHTOLIER
TECHNICAL INFORMATION: (978) 657-7600 - (978) 658-0595 631 AIRPORT ROAD, FALL RIVER, MA 02720 - (508) 679-8131
A GENLYTE COMPANY
www.lightolier.com
CANLYTE www.canlyte.com 525 EDUCATION ROAD, CORNWALL, ONTARIO, CANADA K6H 6C7 - (613) 938-6221 WE RESERVE THE RIGHT TO CHANGE DETAILS OF DESIGN, MATERIALS AND FINISH © 2007 GENLYTE GROUP LLC (LIGHTOLIER DIVISION)
Loading...