Lightolier A7053 User Manual

Ceiling Thickness
1 1/8" (29 mm) max.
5 3/4" (146 mm)
Overlap
45
(340 mm)
13 3/8"
(105 mm)
4 1/8"
5" (127 mm)
Flush
A400 Top View
2 1/8" (54 mm) max.
1" (25 mm) min. -
(267 mm)
10 1/2"
(76 mm)
3"
7 15/16" (202 mm)
4 1/2" Dia. (115 mm)
White Molded
Trim Ring
Flush Trim
(Molded trim ring removed)
White or
Polished Flange
99 88
Remodel (A400RM)
Frame-in Kit
Calculite
®
Incandescent Open Downlight A7053
Page 1 of 2 4 1/2” Aperture A19
Ceiling Cutout: A400 5 1/16" (129 mm) Dia. Ceiling Cutout: A400RM 5" (127 mm) Dia.
Reflector Trim Frame-In Kit Lamp
A7053CLW Specular Clear finish with white flange A400 A19, 100W max. A7053CLP Specular Clear finish with polished flange A7053CL Specular Clear finish with molded trim ring (flangeless) A7053 Add suffix for other finishes (see options).
Remodeler Frame-In Kit Lamp
A400RM (for use in existing ceilings Same as A400
with 3/8” min. to 2” max. thickness.)
Features
1. Reflector: 16 ga. Specular Alzak®aluminum, 50° visual cutoff to lamp and
lamp image. Available with white or polished flange, or with removable white molded trim ring (field paintable).
2. Socket Cup: Die-cast aluminum cup effectively dissipates heat and assures lamps maintain proper optical alignment to reflector. Snaps onto reflector neck for easy tool-less installation. Contains medium base porcelain socket with nickel plated screw shell wired and No. 18 SF-1 leads to J-Box.
3. Mounting Frame: Die-cast aluminum suitable for dry or plaster. Provides flush trim in plaster ceiling.
4. Retaining Springs: Precision-tooled steel friction springs secure reflector to mounting frame for quick, tool-less installation.
5. Mounting Brackets: 16 ga. steel. Adjust from inside of fixture. Use 3/4" or 1 1/2" lathing channel, or optional mounting bars.
6. Junction Box: 16 ga. Steel, 4" x 4" x 2" box allows inspection from below.
7. Thermal Protector: Meets NEC and UL requirements. Insulation must be
kept 3" away from fixture sides and wiring compartments and must not be placed above fixture in a manner which will entrap heat.
8. Multi-Groove Baffle (A7053MG): One piece seamless Aluminum. Sharply detailed concentric rings with “sawtooth” profile, optical black finish. Permanently fastened to Specular Clear reflector.
9. Black Cone (A7053BK): Specular Black Alzak®aluminum. Permanently fas- tened to Specular Clear reflector.
Other Reflector Finish Options
Comfort Clear Diffuse CCD Specular Gold GD White WH Specular Black BK* Multi-Groove Baffle MG*
*Flangeless w/molded trim ring. For additional finishes consult factory.
Flange Options
White W Polished Flange P Flangeless Leave Blank (molded trim ring)
Accessories and Options
18" Mounting Bars 1950 (set of 2) 27" Mounting Bars 1951 (set of 2) T-Bar Anchor Clips 1956 (set of 4, for 1950 & 1951 bars) Existing Ceiling Clips 7998 (set of 2) Sloped Ceiling Adapters 7920(see SCA specification sheet) Step Down Transformer 7997 (see 7997 specification sheet) Chicago Air Plenum LC(add suffix to Frame-in Kit)
Electrical
A400 UL Listed for through branch circuit wiring with max. of (8) No. 12 AWG
90°C supply conductors. A400RM UL Listed for No. 12 AWG 60° C supply con­ductors.
Labels
UL Listed for damp locations, I.B.E.W.
®
is a registered trademark of ALCOA.
Alzak
Job Information Type:
Job Name: Cat. No.:
Lamp(s): Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) • B0204
Calculite
Conversion Factors:
Use quick calculator chart to determine spacing of luminaires for desired level of illumination.
40W A-19 (Black Alzak): F.C. X 0.40; (Multi-groove): F.C. x 0.35 60W A-19 (Black Alzak): F.C. X 0.75; (Multi-groove): F.C. x 0.65 75W A-19 (Multi Groove): F.C. X 0.90;  100W A-19 (Black Alzak): F.C. x 1.5; (Multi-groove): F.C. x1.3
80% Ceiling; 50% Walls; 20% Floor
Room Surface Reflectances:
75 Watt A19 1190 Lumens Per Lamp
RCR = 10 (Rm. Width - Mtg. Ht. above work plane)
RCR = 5 (Rm. Width - 2Mtg. Ht. above work plane)
RCR = 1 (Rm. Width - 10 x Mtg. Ht. above work plane)
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
AREA PER FIXTURE IN SQUARE FEET
INITIAL FOOTCANDLES
109876543
90 100 1108070605040302010
40 35 30 25 20 15 10
0
Conversion Factors:
Use quick calculator chart to determine spacing of luminaires for desired level of illumination.
40W A-19 (Clear): F.C. X 0.40; (Gold): F.C. x 0.35 60W A-19 (Clear): F.C. X 0.75; (Gold): F.C. x 0.65 75W A-19 (Gold): F.C. X 0.90; 100W A-19 (Clear): F.C. x 1.5; (Gold): F.C. x1.3
80% Ceiling; 50% Walls; 20% Floor
Room Surface Reflectances:
75 Watt A19 1190 Lumens Per Lamp
RCR = 10 (Rm. Width - Mtg. Ht. above work plane)
RCR = 5 (Rm. Width - 2Mtg. Ht. above work plane)
RCR = 1 (Rm. Width - 10 x Mtg. Ht. above work plane)
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
AREA PER FIXTURE IN SQUARE FEET
INITIAL FOOTCANDLES
1110 12987654
14012010080604020
40 35 30 25 20 15 10
0
100
200
90°
60°
30°
300
400
125
250
60°
30°
375
500
90°
®
Incandescent Open Downlight A7053
Page 2 of 2 4 1/2” Aperture A19
A7053CL A19 75 Watt
A7053BK A19 75 Watt
Spacing Ratio = 1.2
CANDLEPOWER SUMMARY
ZONE LUMENS LAMP FIXT 0-30 397 33.4 57.4
ITL, Inc. Report No. 23108 Date: 4-4-78 Efficiency: 58.2%
ITL, Inc. report No. 23108C. Date: 4-4-78 ITL, Inc. report No. 23151C. Date: 4-10-78
0-40 570 47.9 82.2 0-60 691 58.1 99.8 0-90 693 58.2 100.0
90-180 0 0 .0
0-180 693 58.2 100.0
COEFFICIENTS OF UTILIZATION
%
EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50 30 10 0
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 2 3 4 5 6 7 8
ROOM CAVITY RATIO
9
10
Conversion Factor: For 40W, 60W and 100W A19 units with clear reflector, multiply C.U.’s by 1.0. For 40W, 60W, 75W and 100W A19 units with gold reflector, multiply C.U.’s by 0.9.
.65 .63 .62 .63 .62 .61 .61 .60 .59 .59 .58 .57 .57 .56 .56 .55 .61 .58 .56 .60 .58 .56 .58 .56 .55 .56 .55 .53 .54 .53 .52 .51 .57 .54 .52 .56 .53 .51 .54 .52 .50 .53 .51 .50 .52 .50 .49 .48 .53 .50 .48 .52 .50 .47 .51 .49 .47 .50 .48 .46 .49 .47 .46 .45 .50 .46 .44 .49 .46 .44 .48 .45 .43 .47 .45 .43 .46 .44 .42 .42 .46 .43 .41 .46 .43 .40 .45 .42 .40 .44 .42 .40 .43 .41 .40 .39 .43 .40 .37 .43 .39 .37 .42 .39 .37 .41 .39 .37 .41 .38 .36 .36 .40 .37 .34 .40 .36 .34 .39 .36 .34 .39 .36 .34 .38 .35 .34 .33 .37 .33 .31 .37 .33 .31 .36 .33 .31 .36 .33 .31 .35 .33 .31 .30 .34 .31 .28 .34 .31 .28 .34 .31 .28 .33 .30 .28 .33 .30 .28 .27
% WALL REFLECTANCE
ZONAL
DEG CP FLUX
0 438
5 440 42 15 420 119 25 511 237 35 274 172 45 155 120 55 2 2 65 0 0 75 0 0 85 0 0 90 0
ZONAL SUMMARY
Spacing Ratio = 1.1
ITL, Inc. Report No. 23151 Date: 4-10-78 Efficiency: 42.9%
CANDLEPOWER SUMMARY
DEG CP FLUX 0 427
5 422 40 15 369 105 25 368 170 35 200 126 45 89 69 55 0 0 65 0 0 75 0 0 85 0 0 90 0
ZONAL SUMMARY
ZONE LUMENS LAMP FIXT 0-30 315 26.5 61.7
0-40 441 37.0 86.3 0-60 510 42.8 99.8 0-90 511 42.9 100.0
90-180 0 0.0 0.0
0-180 511 42.9 100.0
ZONAL
COEFFICIENTS OF UTILIZATION
%
EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50 30 10 0
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1
.48 .47 .46 .47 .46 .45 .45 .44 .44 .44 .43 .42 .42 .42 .41 .40
2
.45 .43 .42 .44 .43 .42 .43 .42 .41 .42 .41 .40 .40 .40 .39 .38
3
.42 .40 .39 .42 .40 .38 .40 .39 .38 .39 .38 .37 .39 .37 .37 .36
4
.40 .38 .36 .39 .37 .36 .38 .37 .35 .37 .36 .35 .37 .35 .34 .34
5
.37 .35 .33 .37 .35 .33 .36 .34 .33 .35 .34 .32 .35 .33 .32 .32
6
.35 .33 .31 .35 .32 .31 .34 .32 .31 .34 .32 .30 .33 .31 .30 .30
7
.33 .30 .29 .33 .30 .29 .32 .30 .28 .32 .30 .28 .31 .29 .28 .28
8
.31 .28 .27 .30 .28 .26 .30 .28 .26 .30 .28 .26 .29 .27 .26 .26
ROOM CAVITY RATIO
9
.29 .26 .24 .28 .26 .24 .28 .26 .24 .28 .26 .24 .27 .25 .24 .24
10
.27 .24 .23 .27 .24 .23 .26 .24 .23 .26 .24 .22 .26 .24 .22 .22
% WALL REFLECTANCE
Conversion Factor: For 40W, 60W and 100W A19 units with black Alzak, multiply C.U.’s by
1.0. For 40W, 60W, 75W and 100W A19 units with Multi-Groove, multiply C.U.’s by 0.9.
Job Information Type:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) • B0204
Loading...