Lightolier 83ED17 User Manual

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
REMOVAL SLOT
ROTATION STOP
REFLECTOR SPRING
REFLECTOR LIP
REFLECTOR SPRINGS
REFLECTOR
REFLECTOR CUP
ED17 SPOT
REFLECTOR
LABEL
FIG. 6
FIG. 7
(UP POSITION)
This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
INSTRUCTIONS FOR A TTACHING 83ED17R SERIES REFLECTORS TO
POWERARC MODULAR ED17 LYTESPOT (ROUND OR SQUARE FRONT)
INSTRUCTIONS FOR ATTACHING 83ED17R SERIES REFLECTORS TO A PowerArc ED17 SPOT:
(See chart below for compatible luminaires)
COMPATIBLE LUMINAIRES
Cat. No. Product Group Description
INSTRUCTION SHEET NO.
IS:83ED17
C0104 Page 1 of 2
TM
8307
ED17 Open/Square Lytespot for Protected Lamp
Lytespan Track
ED17 Enclosed/Round Lytespot for Protected Lamp
ED17 Open/Square Lytespot for Unprotected Lamp
ED17 Enclosed/Round Lytespot for Unprotected Lamp
8317
8307U
8317U
NOTE: Reflectors must be installed prior to lamps. After reflector is installed, see IS:83S for installation, lamp­ing, and operating instructions.
1. Orienting LABEL in the UP position, hold REFLECTOR by the LIP and push into REFLECTOR CUP until REFLECTOR SPRINGS engage. (See FIG. 6 and 7).
2. Rotate REFLECTOR clockwise until the REFLECTOR SPRINGS hit the ROTATION STOPS on the REFLEC­TOR CUP. (See FIG. 7)
To remove REFLECTOR:Remove lamp, rotate REFLECTOR counterclockwise until REFLECTOR SPRINGS snap into REMOVAL SLOTS. Pull REFLEC­TOR out of REFLECTOR CUP. (See Fig. 7)
LIGHTOLIER a GENLYTE THOMAS company.
631 Airport Road, Fall River, MA 02720
Fig. 1
REFLECTOR
REFLECTOR
SPRINGS
REFLECTOR
CUP
ACCESS
KNOB
ED17 LYTESPOT
ACCESSORY
CARTRIDGE
LIP
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING LUMINAIRE.
Fig. 2
REFLECTOR
REFLECTOR
SPRINGS
ROTATION
STOP
REMOVAL
SLOT
This luminaire is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
INSTRUCTIONS FOR A TTACHING 83ED17R SERIES REFLECTORS TO
ED17 HID LYTESPOTS SERIES LUMINAIRES.
INSTRUCTIONS FOR ATTACHING 83ED17R SERIES REFLECTORS TO AN HID ED17 LYTESPOT LUMINAIRE:
(See chart below for compatible luminaires)
COMPATIBLE LUMINAIRES
Cat. No. Product Group Description
8387 ED17 50W Magnetic HID Lytespot
8387E ED17 50W Electronic HID Lytespot
8388 Lytespan Track ED17 70W Magnetic HID Lytespot 8388E ED17 70W Electronic HID Lytespot 8389E ED17 100W Electronic HID Lytespot
PDE17 Series ED17 HID Pull-Down SRE17 Series
Calculite
ED17 HID Semi-Recessed
INSTRUCTION SHEET NO.
IS:83ED17
C0104 Page 2 of 2
NOTE: Reflectors must be installed prior to lamps. After reflector is assem­bled, see IS:8387 for Lytespot installation, lamping, accessory, and operating instructions.
1. If Lytespot is already attached onto a track, make sure power to the track is turned off before proceeding.(Lytespan Track luminaire is shown in Figs. 1 & 2. Instructions 2-4 are the same when using Calculite luminaire.
2. Holding ACCESSORY CARTRIDGE, loosen ACCESS KNOB a few turns until ACCESSORY CARTRIDGE opens. SWING the CARTRIDGE open for access to REFLECTOR CUP (See Fig. 1).
3. Holding REFLECTOR by the LIP, push REFLECTOR into REFLECTOR CUP until REFLECTOR SPRINGS engage (See Fig. 2)
4. Rotate REFLECTOR clockwise until the REFLECTOR SPRINGS
hit the ROTATION STOPS on the REFLECTOR CUP (See fig. 2).
To remove REFLECTOR, remove lamp, rotate REFLECTOR counter-clockwise until REFLECTOR SPRINGS snap off into REMOVAL SLOTS. Pull REFLECTOR out of REFLECTOR CUP (See fig. 2).
LIGHTOLIER a GENLYTE THOMAS company.
631 Airport Road, Fall River, MA 02720
Loading...