Ordering Information
Catalog No. Finishes Track Mountings Lamps
8292F3EWH Matte White 70W CDM or CMH T-6 8292F3EBK Matte Black Double Ended Metal Halide (M-98) 8292F3EAL Metallic Aluminum
Features
1. Ballast Housing: 0.09” extruded aluminum housing with die cast endcaps.
2. Ballast: High power factor electronic metal halide ballast.
3. Reflector Housing: .095” thick extruded aluminum body with die cast end
caps.
4. Vertical Pivot: 0 - 90° vertical adjustment.
5. Horizontal Pivot: Die cast track adapter with positive rotation stop provides
385° horizontal rotation.
6. Sockets: 5 Kv pulse rated sockets with nickel plated contacts; leads
enclosed in silicone coated fiberglass sleeving.
7. Contact Holder: High temperature thermoplastic. Secures luminaire
mechanically and makes electrical contact with track.
8. Brass Contact: Extends for connection to second circuit in Advent®
Lytespan® track.
9. Flood Reflector: Symmetrical aluminum reflector for illumination on vertical
surface.
10. Safety Interlock Switch: Disconnects power when safety lens is removed.
11. Safety Lens: Tempered 1/8” UV filtering glass. Meets or exceeds safety
requirements for metal halide lamps.
12. Indicator Guide: Aiming indicator assures consistent and precise multiple
unit alignment.
13. Locking Lever: Nickel plated steel. For mechanical/electrical connection to
track.
All Lytespan® Track Systems, Multipoint, and Monopoint. DO NOT USE with any other mounting accessories or stem mounted Radius® Track.
Electrical (Continued)
Harmonic Distortion: <10%
DO NOT USE ON A DIMMING CIRCUIT
Options and Accessories
Accepts PowerArc Accessory Holder (8293AC), Vertical Blade Louver (8293LV), Spread Lens (8293BE), UV Filter (8293UV), and Visor (8293VS).
NOTE: 8293UV or 8293BE must be combined with 8293AC.
Finish
All painted finishes are baked enamel.
Labels
UL, cUL
Job Name:
Cat. No.:
Lamp(s): Notes:
Electrical
Electronic Ballast Input Voltage: 120V, 60Hz Power Factor: >95% Input Power: 78W
Input Current: .67 amp
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 Genlyte Group LLC • C0807
Lytespan
®
Track Lighting 8292F3E
Page 2 of 2 PowerArc™ Double Ended Metal Halide 30° Vertical Flood
Aiming Angle 30° Horizontal 30° Vertical 45° Vertical
L Beam Length W Beam Width C Distance to center beam D Distance A Aiming Angle FC Footcandles
L and W are the outer points where the candle
power drops to 50% of the maximum. FC are the initial footcandles at the center of the beam.
30° Horizontal 30° Vertical 45° Vertical
Beam Spread (To 50% CBCP) Life (Hrs.)
T6 70W MasterColor Metal Halide 29° x 85°
La mp Information:
70W CDM or CMH T6 Double Ended Metal Halide. Initial Lumens: 6200 to 7000 CRI: 85 Rated Avg. life: 12,000 hrs.
Rated
CBCP
5,659 12,000
5,659 12,000
D FC L W
6’ 157 3.1’ 11.0’ 8’ 88 4.1’ 14.7’ 10’ 57 5.2’ 18.3’ 12’ 38 6.2’ 22.0’
D C FC L W
5’ 2.9’ 147 3.5’ 10.6’ 7’ 4.0’ 75 4.9’ 14.8’ 8’ 5.2’ 45 6.3’ 19.0’ 11’ 6.4’ 30 7.8’ 23.3 ’
D C FC L W
2’ 3.5’ 177 5.2’ 7.3’ 3’ 5.2’ 79 7.8’ 11.0’ 4’ 5.9’ 44 10.4’ 14.7’ 5’ 8.7' 28 12.9’ 18.3’
D C FC L W
3’ 3.0’ 222 3.3’ 7.8’ 5’ 5.0’ 80 5.5’ 13.0’ 7’ 7.0’ 41 7.8’ 16.1’ 9’ 9.0’ 25 10.0’ 23.3’