Lightolier 8091CB User Manual

Calculite
7
2
345
6
6"
(152 mm)
5-7/8"" (149 mm) Dia.
7-1/4" Self-Flanged
Trim (184 mm)
1" (25 mm) min.­2-1/8" (54 mm) max.
1-1/8" (29 mm) max.
Ceiling Thickness
3"
(76 mm)
1
4 5/8"
(117mm)
10"
(254mm)
12 3/4"
(324mm)
®
CFL Open Downlight 8091CB
Page 1 of 2 6" Aperture Triple Tube Cross Blade Louver
Reflector Trim Frame-In Kit
8091CBW White Cone, White Flange 8091CBA Aluminum Cone, White Flange
S6132BU 6" aperture, 1 lamp 26/32W Triple Tube CFL (120/277V) 4-Pin (Amalgam) Dimming Options:
S6132B CU3 Lightolier PowerSpec 3% Dimming (120/277V) J1LD 3 Lutron 3% Dimming (120V) J2LD3 Lutron 3% Dimming (277V) JUM7 Mark 7 Dimming (120/277V) J1MX Mark 10 Dimming (120V) J2MX Mark 10 Dimming (277V)
Other dimming product available, please consult factory
Remodeler Frame-In Kits
6126BURM 6" aperture, 1 lamp 26W Triple Tube CFL (120/277V) 4-Pin (Amalgam)
6132BURM 6" aperture, 1 lamp 26/32W Triple Tube CFL (120/277V) 4-Pin (Amalgam)
Features
1. Reflector: 16 ga. Die-formed aluminum, Anobrite® finish.
2. Socket Cup: Effectively dissipates heat and positions lamp holder.
Snaps onto reflector neck to assure consistently correct optical alignment without tools.
3. Mounting Frame: Galvanized steel for dry or plaster ceilings. Accepts other 6” Triple Tube reflectors (see S6132BU Spec Sheet).
4. Retaining Springs: Precision-tooled steel friction springs secure reflector to mounting frame for quick, tool-less installation.
5. Mounting Brackets: 16 ga. steel. Adjust from inside of fix ture. Use 3/4" or 1 1/2" lathing channel, 1/2" EMT, or optional mounting bars.
6. Ballast/J-Box: Electronic 120V-277V. UL listed for through branch circuit wiring with max of (8) No. 12AWG, 90°c supply conductors. Outboard­mounted to reduce heat transfer and maintain lamp efficacy and life. Service from below without tools.
7. Cross Blade Louver: Die-formed, 16 ga. aluminum, matte white or painted aluminum finish. Accepts lens (consult factor y). 50° cutoff to lamp, medium beam. Keyed for orientation.
Electrical
Note: For ballast electrical data and latest lamp/ballast compatibility refer to “Ballast” specification sheet for complete electrical data.
UL Listed for through branch circuit wiring with max of (8) No 12 AWG, 90 degree C supply conductors.
Options and Accessories
Other Louver Finishes Consult Factor y
Emergency Add suffix EM* Chicago Plenum Use 6132BULC Existing/Thk. Ceiling FA EC6* Emergency Ltg. Kit FA EM3E* Fuse (Slow Blow) Add Suffix F *See Spec. Sheets: FAEC, FAEM
Mounting Bars & Accessories; see Specification Sheet MBA. Sloped Ceiling Adapters; see Specification Sheet SCA.
IC Frame available; see C6CFL32 specification sheet.
Labels
UL listed for damp locations.
Job Name:
Job Name:
Cat. No.:
Cat. No.:
Lamp(s):
Lamp(s): Notes:
Notes:
Lightolier is a Philips group brand
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • A0708
Calculite
** EFFICIENCY = 33.5% **** EFFICIENCY = 33.5% **
** EFFICIENCY = 33.5% **** EFFICIENCY = 33.5% **
** EFFICIENCY = 33.5% **
Quick Calculator
Spacing Ratio = 1.1
CERTIFIED TEST REPORT NO. 0194FR COMPUTED BY LSI PROGRAM **TEST-LITE** CALCULITE 5 3/4" DIA. APERTURE RECESSED FLUORESCENT CROSS BLADE DOWNLIGHT WITH WHITE CROSS BLADE 1-32W PL-T COMPACT FLUORESCENT LAMP. LUMEN RATING = 2400 LMS. TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
60
50
40
30
20
10
10 20 30 40 50 60 70
AREA PER FIXTURE IN SQUARE FEET
23 45 67 8
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
This quick calculator chart determines the number and spacing of 1 It.- 32W PL-T units with white cross blade, for any level of illumination. Conversion Factors: 32W PLT with Aluminum Cross Blade, f.c. x 0.7; 26W PLT with white cross blade, f.c. x 0.8; 26W with Aluminum Cross Blade, f.c. x 0.6.
INITIAL FOOTCANDLES
ROOM SURFACE REFLECTANCES:
80% Ceiling; 50% Wall; 20% Floor
2400 Lumens Per Lamp RCR= 1 (Rm. Width= 10xMtg. Ht. above work plane)
RCR= 5 (Rm. Width= 2xMtg. Ht. above work plane) RCR=10 (Rm. Width= Mtg. Ht. above work plane)
Coefficients Of Utilization
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50 30 10 0
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .36 .35 .34 .36 .35 .34 .34 .34 .33 .33 .32 .32 .32 .31 .31 .30 2 .33 .32 .30 .33 .31 .30 .31 .30 .29 .31 .30 .29 .30 .29 .28 .27 3 .30 .28 .27 .30 .28 .27 .29 .28 .26 .28 .27 .26 .27 .26 .25 .25
4 .28 .26 .24 .28 .26 .24 .27 .25 .24 .26 .25 .24 .26 .24 .23 .23 5 .26 .24 .22 .26 .23 .22 .25 .23 .22 .24 .23 .21 .24 .22 .21 .21
6 .24 .22 .20 .24 .22 .20 .23 .21 .20 .23 .21 .20 .22 .21 .20 .19 7 .22 .20 .18 .22 .20 .18 .21 .19 .18 .21 .19 .18 .21 .19 .18 .17
8 .21 .18 .17 .20 .18 .17 .20 .18 .17 .20 .18 .17 .19 .18 .16 .16 9 .19 .17 .15 .19 .17 .15 .19 .17 .15 .18 .16 .15 .18 .16 .15 .15
10 .18 .16 .14 ..18 .16 .14 .17 .15 .14 .17 .15 .14 .17 .15 .14 .13
20% FLOOR CAVITY REFLECTANCE
Conversion Factors: 32W PLT with Aluminum Cross Blade, C.U. x 0.7;
26W PLT with White Cross Blade, C.U. x 1.1; Aluminum Cross Blade, C.U. x 0.8.
ROOM CAVITY RATIO
CANDLEPOWER
ANGLE ALONG 22.5 45 67.5 ACROSS LUMENS
0 593 593 593 593 593
5 575 575 580 584 585 55 10 536 538 541 549 558 15 487 485 491 522 542 142 20 436 427 439 478 506 25 377 366 388 425 460 184 30 309 301 325 366 402 35 228 233 254 279 308 163 40 166 178 185 192 214 45 128 133 126 129 146 105 50 93 93 92 97 104 55 73 73 74 79 84 69 60 58 58 59 64 68 65 45 45 47 51 53 48 70 34 35 36 39 40 75 24 24 26 28 29 28 80 15 16 17 18 20 85 778101110 90 32344
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP%LUMINAIRE
0-30 380 15.86 47.31 0-40 544 22.67 67.61 0-60 718 29.93 89.28
0-90 804 33.53 100.00 40-90 260 10.86 32.39 60-90 86 3.59 10.72
90-180 0 .00 .00
0-180 804 33.53 100.00
ACROSS 45 ALONG
180150
120
90
60
30
0
400
200
600
®
CFL Open Downlight 8091CB
Page 2 of 2 6" Aperture Triple Tube Cross Blade Louver
Lightolier is a Philips group brand
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • A0708
Loading...