Lightolier 8056 User Manual

Calculite
2
®
CFL Open Downlight 8056
Page 1 of 2 7 3/8" Aperture (2) Quad Tube Horizontal Lamp
2
14-5/8"
(372 mm)
5
5-1/4"
(134 mm)
11-3/8"
(289 mm)
12-1/2"
(318 mm)
Top View
6-7/8"
(175 mm)
1" (25 mm) min.-
-1/8" (54 mm) max.
3"
(76 mm)
4
7-3/8" (187 mm) Dia.
7-7/8" Trimless (200 mm)
Reflector Trim Frame-In Kit
8056 CLW Clear Iridescence Free, White Flange 8056 CLP Clear Iridescence Free, Polished Flange 8056 CL Clear Iridescence Free, Molded Trim Ring 8056 Add suffix. See options for other finishes.
Features
1. Reflector: 16 ga. Die-formed aluminum, Anobrite finish.
2. Socket Cup: Snaps onto reflector neck to assure consistently correct optical
alignment without tools.
4. Retaining Springs: Precision-tooled steel friction springs secure reflector to
mounting frame for quick, tool-less installation.
5. Mounting Brackets: 16 ga. steel. Adjust from inside of fixture. Use 3/4" or
1 1/2" lathing channel, 1/2" EMT, or optional mounting bars.
6. Ballast/J-Box: Outboard mounted to reduce heat transfer and maintain
lamp efficacy and life. Service from below without tools.
Electrical
Note: For ballast electrical data and latest lamp/ballast compatibility refer to “Ballast” specification sheet for complete electrical data.
UL listed for through branch circuit wiring with max of (8) No. 12 AWG, 90° C supply conductors.
Options and Accessories
Comfort Clear™ Finishes1 Other Finishes
Clear CCL White WH Diffuse CCD Champagne Bronze CCZ
1
Specif y desired flange
W White, P Polished Factory Emergency Add suffix EM* Chicago Plenum Add suffix LC
S7218HU 7" aperture, 2 lamp 18W Quad Tube CFL (120/277V) 4-pin S7226HU 7" aperture, 2 lamp 26W Quad Tube CFL (120/277V) 4-pin
Dimming Options:
S7218H or S7226H CU3 Lightolier PowerSpec 3% Dimming (120/277V) J1LD3 Lutron 5% Dimming (120V) J2LD3 Lutron 5% Dimming (277V) JUM7 Mark 7 Dimming (120/277V J1MX Mark 10 Dimming (120V) J2MX Mark 10 Dimming (277V)
Other dimming product available, please consult factory
Options and Accessories (continued)
Existing/Thk. Ceiling FA EC7* Field Emergency Kit FA EM3E* (4 pin)
FA EM4E* (4 pin)
Fuse (Slow Blow) Add Suf fix F *See Spec. Sheets: FAEC, FAEM
Mounting Bars & Accessories; see Specification Sheet MBA. Sloped Ceiling Adapters; see Specification Sheet SCA.
Labels
UL listed for damp locations
Alzak® is a registered trademark of ALCOA.
US Patent Pending.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s): Notes:
8-5/8" Self-Flanged Trim (209 mm)
1
6
3
1-1/8" (29 mm) max. Ceiling Thickness
Lightolier is a Philips group brand
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • C1108
Calculite
®
CFL Open Downlight 8056
Page 2 of 2 7 3/8" Aperture (2) Quad Tube Horizontal Lamp
18W Quick Calculator
60
50
INITIAL FOOTCANDLES
40
30
20
10
20 40 60 80 100 120 140
4 5 6 7 8 9 10 11 12
This quick calculator chart determines the number and spacing of 2 Lt. 18 watt Quad Tube units with clear or clear iridescent free reflector for any level of illumination.
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
ROOM SURFACE REFLECTANCES:
80% Ceiling; 50% Wall, 20% Floor
1250 Lumens Per Lamp RCR= 1 (Rm. Width = 10xMtg. Ht. above work plane)
RCR= 5 (Rm. Width = 2xMtg. Ht. above work plane) RCR=10 (Rm. Width = Mtg. Ht. above work plane)
AREA PER FIXTURE IN SQUARE FEET
Spacing Ratio: 1.4
Test Report Number: LRL 889-5A COMPUTED BY: LIGHTING RESEARCH LABORATORY PREPARED FOR: LIGHTOLIER INC. APERTURE: 7 1/2” REFLECTOR: SPECULAR CLEAR ALZAK LAMPS: TWO 18W QUAD TUBE LAMPS EACH RATED AT 1250 LUMINES.
CANDELPOWER SUMMARY
90
Angle ALONG 22.5 45 67.5 ACROSS
0 614 614 614 614 614
5 616 618 641 632 642 15 629 651 733 697 720 25 625 645 748 690 743
60
35 572 599 709 674 703 45 318 322 413 383 396 55 24 25 28 27 25 65 3 3 4 3 3 75 3 3 3 3 3 85 2 3 3 2 2 90 0 0 0 0 0
ZONAL LUMENS AND PERCENTAGES
0
**EFFICIENCY = 52.3%**
DATE: August 8, 1989
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES
THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
Zone Lumens % Lamp % Luminaire 0–30 576 23.0 44.0
30
0–40 987 39.5 75.5 0–60 1298 51.9 99.3 0–90 1307 52.3 100.00 90–180 0 .00 .00 0–180 1307 52.3 100.00
Coefficients Of Utilization
% Effective Ceiling Cavity Reflectance
80 70 50 30 10 0
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .58 .56 .55 .57 .55 .54 .54 .53 .53 .52 .52 .51 .51 .50 .49 .49
ROOM CAVITY RATIO
2 .54 .52 .50 .53 .51 .49 .51 .50 .48 .50 .48 .47 .48 .47 .46 .45 3 .50 .48 .46 .49 .47 .45 .48 .46 .44 .47 .45 .44 .46 .44 .43 .42 4 .46 .44 .41 .46 .43 .41 .45 .42 .41 .44 .42 .40 .43 .41 .40 .39 5 .43 .40 .38 .43 .40 .38 .42 .39 .37 .41 .39 .37 .40 .38 .37 .36 6 .40 .37 .34 .40 .37 .34 .39 .36 .34 .38 .36 .34 .37 .35 .34 .33 7 .37 .34 .31 .37 .34 .31 .36 .33 .31 .35 .33 .31 .35 .32 .31 .30 8 .34 .31 .28 .34 .31 .28 .33 .30 .28 .33 .30 .28 .32 .30 .26 .27 9 .31 .28 .25 .31 .28 .25 .30 .27 .25 .30 .27 .25 .29 .27 .25 .24
10 .27 .23 .21 .27 .23 .21 .26 .23 .21 .26 .23 .31 .25 .23 .21 .20
%Wall Reflectance
20% FLOOR CAVITY REFLECTANCE
ZONAL
SUMMARY
Zone Avg Zonal
0 614
Deg. C.P. Lumens
5 630 60 15 689 195 25 692 320 35 655 411 45 371 288 55 26 23 65 3 3 75 3 3 85 3 3 90 0 0 95 0 0
105 0 0 115 0 0 125 0 0 135 0 0 145 0 0 155 0 0 165 0 0 175 0 0 180 0 0
26W Quick Calculator
80
70
INITIAL FOOTCANDLES
60
50
40
30
20
10
25 50 75 100 125 150 175 200
3 4 5 6 7 8 9 10 11 12 13 14
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
This quick calculator chart determines the number and spacing of 26 watt Quad Tube units with clear reflector, for any level of illumination. Lighting Conversion Factors: Gold, F.C. x 0.9; Black, F.C. x 0.85; Multi-Groove, F.C. x 0.8.
ROOM SURFACE REFLECTANCES:
80% Ceiling; 50% Wall, 20% Floor
1800 Lumens Per Lamp RCR= 1 (Rm. Width = 10xMtg. Ht. above work plane)
RCR= 5 (Rm. Width = 2xMtg. Ht. above work plane) RCR=10 (Rm. Width = Mtg. Ht. above work plane)
AREA PER FIXTURE IN SQUARE FEET
Spacing Ratio = 1.6
Certified Test Report Number: ITL 40604 COMPUTED BY: INDEPENDANT TESTING LABORATORIES, INC PREPARED FOR: LIGHTOLIER INC. APERTURE: 7 3/8” REFLECTOR: SPECULAR CLEAR LAMPS: TWO 26W 4 PIN QUAD TUBE COMPACT FLUORESCENT RATED AT 1800 LUMENS.
ACROSS 45 ALONG
90
400
800
1200
0
**EFFICIENCY = 56.0%**
DATE: MAY 28, 1993
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES
THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
60
30
CANDLEPOWER SUMMARY
Angle 0.0 45.0 90.0 135.0 180.0 Flux
0 836 836 836 836 836
5 843 889 896 893 839 86 15 898 1080 1142 1051 864 293 25 957 1039 1058 992 914 465 35 880 953 938 925 817 571 45 620 723 690 676 596 415 55 28 43 39 43 37 81 65 4 4 4 4 4 5 75 2 2 2 2 2 2 85 0 0 0 0 0 0 90 0 0 0 0 0
ZONAL LUMENS AND PERCENTAGES
Zone Lumens % Lamp % Luminare 0–30 844 23.5 41.9 0–40 1415 39.3 70.1 0–60 2011 55.9 99.7 0–90 2018 56.0 100.0 90–180 0 .00 .00 0–180 2018 56.0 100.0
Coefficients Of Utilization
% Effective Ceiling Cavity Reflectance
80 70 50 30 10 0
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .61 .59 .58 .60 .58 .57 .58 .56 .55 .55 .55 .54 .54 .53 .52 .51
ROOM CAVITY RATIO
2 .56 .53 .51 .55 .52 .50 .53 .51 .49 .51 .49 .48 .50 .48 .47 .46 3 .51 .47 .45 .50 .47 .44 .48 .46 .43 .47 .45 .43 .46 .44 .42 .41 4 .46 .42 .39 .45 .42 .39 .44 .41 .39 .43 .40 .38 .42 .40 .38 .37 5 .42 .38 .35 .42 .38 .35 .40 .37 .35 .39 .37 .34 .39 .36 .34 .33 6 .39 .34 .31 .38 .34 .31 .37 .34 .31 .36 .33 .31 .35 .33 .31 .30 7 .35 .31 .28 .45 .31 .28 .34 .31 .28 .33 .30 .28 .33 .30 .28 .27 8 .33 .28 .26 .32 .28 .26 .31 .28 .25 .31 .28 .25 .30 .27 .25 .24 9 .30 .26 .23 .30 .26 .23 .29 .26 .23 .29 .25 .23 .28 .25 .23 .22
10 .28 .24 .21 .27 .24 .21 .27 .24 .21 .26 .23 .21 .26 .23 .21 .20
%Wall Reflectance
20% FLOOR CAVITY REFLECTANCE
Lightolier is a Philips group brand
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • C1108