Lightolier 8038TB User Manual

Calculite
TOP VIEW
1
2
4
5
3
6
8"
(203 mm)
8-11/16" (226 mm) Dia.
9-3/16" Trimless (233 mm)
9-7/8" (251 mm) Self-flange Trim
3"
(76 mm)
1" (25 mm) min.­2-1/8" (54 mm) max.
1-1/8" (29 mm) max. Ceiling Thickness
7
5-3/4"
(146 mm)
14"
(356 mm)
12-3/4"
(324 mm)
®
CFL Open Downlight 8038TB
Page 1 of 2 8 3/4" Aperture (2) Triple Tube Turbo Louver
Ceiling Cutout: 9 1/4" (235 mm) Dia.
Reflector Trim Frame-In Kit
8038 TBW Clear Iridescence Free, White Flange 8038 TBP Clear Iridescence Free, Polished Flange 8038 CTBW Comfort Clear, White Flange 8038 CTBP Comfort Clear, Polished Flange
Features
1. Reflector: 16 ga. Specular Alzak® aluminum. Iridescence Free finish. Self-
flanged trim.
2. Socket Bracket: Die-formed steel, vented. Attaches to reflector for correct
optical alignment.
3. Mounting Frame: Die-cast aluminum for dry or plaster ceilings.
4. Retaining Springs: Precision-tooled steel friction springs secure reflector to
mounting frame for quick, tool-less installation.
5. Mounting Brackets: 16 ga. steel. Adjust from inside of fixture. Use 3/4" or 1
1/2" lathing channel, 1/2" EMT, or optional mounting bars.
6. Ballast/J-Box: Outboard mounted to reduce heat transfer and maintain lamp
efficacy and life. Service from below without tools.
7. Turbo Louver: Radial assembly; Specular Alzak® aluminum, removable and
keyed for orientation. 50° visual cutoff, medium beam.
Electrical
Note: For ballast electrical data and latest lamp/ballast compatibility refer to “Ballast" specification sheet for complete electrical data.
UL listed for through branch circuit wiring with max of (8) No. 12 AWG, 90° C supply conductors.
S8242HU 8" aper ture, 2 lamp 26/32/42W Triple Tube CFL (120/277V) 4-Pin (Amalgam)
Dimming Options: S8242H
DU3 Lightolier PowerSpec 3% Dimming (120/277V) J1LD3 Lutron 3% Dimming (120V) J2LD3 Lutron 3% Dimming (277V) JUM7 Mark 7 Dimming (120/277V) J1MX Mark 10 Dimming (120V) J2MX Mark 10 Dimming (277V)
Other dimming product available, please consult factory
Remodeler Frame-In Kits
8242HURM 8" aperture, 2 lamp 26/32/42W Triple Tube CFL (120/277V) 4-Pin (Amalgam)
Options and Accessories
Emergency Add suffix EM* Chicago Plenum Add suffix LC Emergency Ltg. Kit FA EM3E*
FA EM4E*
Fuse (Slow Blow) Add Suffix F
* See Specification Sheet, FA EM
Mounting Bars & Accessories; see Specification Sheet MBA. Sloped Ceiling Adapters; see Specification Sheet SCA.
Labels
UL Listed suitable (for damp locations), I.B.E.W.
Alzak® is a registered trademark of ALCOA.
US Patent Pending.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s): Notes:
Lightolier is a Philips group brand
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • A0708
Calculite
Spacing Ratio: 1.4
42W
CERTIFIED TEST REPORT N0. LSC6698
COMPUTED BY LSC PROGRAM *TEST-LITE*
LIGHTOLIER RECESSED COMPACT FLOUR. DOWNLIGHT WITH SPECULAR
REFLECTOR AND SPECULAR TURBO BAFFLE
TWO 42W PL-T COMPACT FLUORESCENTS. LUMEN RATING =3200 LMS
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50 30 10 0
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .57 .56 .55 .56 .55 .54 .54 .53 .52 .52 .51 .51 .50 .50 .49 .48 2 .53 .51 .39 .52 .50 .49 .51 .49 .48 .49 .48 .47 .48 .47 .46 .45 3 .50 .47 .45 .49 .47 .45 .48 .46 .44 .46 .45 .43 .45 .44 .43 .42 4 .46 .44 .41 .46 .43 .41 .45 .42 .41 .44 .42 .40 .43 .42 .40 .39 5 .43 .40 .38 .43 .40 .38 .42 .39 .37 .42 .39 .37 .40 .38 .37 .36 6 .40 .37 .35 .40 .37 .35 .39 .36 .34 .38 .36 .34 .38 .36 .34 .33 7 .37 .34 .32 .37 .34 .32 .36 .33 .32 .35 .33 .32 .35 .33 .31 .30 8 .34 .31 .29 .34 .31 .29 .34 .31 .29 .33 .30 .29 .32 .30 .28 .28
9 .32 .29 .26 .31 .28 .26 .31 .28 .26 .31 .28 .26 .30 .28 .26 .25
10 .29 .26 .24 .29 .26 .24 .29 .26 .24 .28 .26 .24 .28 .25 .24 .23
20% FLOOR CAVITY REFLECTANCE
ROOM CAVITY RATIO
180150
120
90
60
30
0
1000
3000
2000
CANDLE POWER SUMMARY
ANGLE MEAN CP LUMENS
0 1833
5 1880 186 10 1999 15 2104 592 20 2121 25 2104 951 30 1892 35 1585 968 40 1159 45 687 528 50 254 55 42 67 60 10 65 02 70 0 75 00 80 0 85 00 90 0
ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 1729 27.02 52.49 0-40 2697 42.15 81.86 0-60 3292 51.45 99.93 0-90 3294 51.48 100.00 40-90 597 9.34 18.14 60-90 2 .03 .07 90-180 0 0.0 0.0 0-180 3294 51.48 100.0
** EFFICIENCY =51.5% **
DATE: SEPT 4, 1996 PREPARED FOR: LIGHTOLIER
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE
GREATEST LUMINOUS OPENING OF LUMINAIRE.
32W Spacing Ratio: Along = 1.4 Across = 1.6
CERTIFIED TEST REPORT N0. LSC6639
COMPUTED BY LSC PROGRAM **TEST-LITE**
RECESSED 8-3/4" DIA. OPEN SPECULAR REFLECTOR AND THREE BLADE TURBO
LOUVERWITH SPECULAR REFLECTOR AND SPECULAR TURBO BAFFLE
TWO 32-WATT PL-T COMPACT FLUOR. LAMPS. LUMEN RATING =2400 LMS
Coefficients Of Utilization
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50 30 10 0
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .54 .53 .52 .53 .52 .51 .50 .49 49 .49 .49 .48 .48 .47 .46 .46 2 .51 .49 .47 .50 .48 .46 .48 .47 .45 .47 .45 .44 .45 .44 .43 .43 3 .47 .45 .43 .36 .44 .42 .45 .43 .42 .44 42 .41 .43 .42 .40 .40 4 .44 .41 .39 .43 .41 .39 .42 .40 .3 .41 .39 .38 .40 .39 .38 .37 5 .41 .38 .36 .40 .38 .36 .39 .37 .35 .39 .37 .35 .38 .36 .35 .34 6 .38 .35 .33 .38 .35 .33 .37 .34 .33 .36 .34 .32 .36 .34 .32 .31 7 .35 .32 .30 .35 .32 .30 .34 .32 .30 .34 .31 .30 .33 .31 .29 .29 8 .33 .30 .27 .32 .29 .27 .332 .29 .27 .31 .29 .27 .31 .29 .27 .26
9 .30 .27 .25 .30 .27 .25 .29 .27 .25 .29 .26 .25 .28 .26 .24 .24
10 .28 .25 .23 .27 .25 .23 .27 .24 .22 .27 .24 .22 .26 .24 .22 .22
20% FLOOR CAVITY REFLECTANCE
For 26W lamps, multiply C.U.'s by 0.95
ROOM CAVITY RATIO
CANDLE POWER SUMMARY
ANGLE ALONG 22.5 45 67.5 ACROSS LUMENS
0 1337 1337 1337 1337
5 1306 1328 1367 1401 1429 134 10 1272 1284 1424 1537 1595 15 1293 1314 1500 1622 1691 410 20 1330 1376 1513 1625 1631 25 1323 1359 1470 1610 1608 608 30 1176 1231 1336 1423 1478 35 972 1007 1167 1106 1188 682 40 772 799 835 880 894 45 510 491 511 544 522 393 50 210 190 186 219 217 55 28 19 20 20 23 47 60 3 0041 65 0 00001 70 0 0000 75 0 00000 80 0 0000 85 0 00000 90 0 0000
ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 1220 25.42 52.06 0-40 1902 39.63 81.17 0-60 2342 48.81 89.96 0-90 2341 48.88 100.00 40-90 441 9.20 18.83 60-90 0 .02 .84 90-180 0 0.00 0.00 0-180 2343 48.83 100.00
** EFFICIENCY = 48.8% **
DATE: JUL 26 1996
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE
GREATEST LUMINOUS OPENING OF LUMINAIRE.
ACROSS 45 ALONG
180 150
120
90
60
30
0
1000
3000
2000
Coefficients Of Utilization
®
CFL Open Downlight 8038TB
Page 2 of 2 8 3/4" Aperture (2) Triple Tube Turbo Louver
Lightolier is a Philips group brand
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • A0708