Calculite
®
Accessories/Option 7997
Page 1 of 1 Incandescent Step Down Transformer
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902
Features
1. Transformer: For supplying a 120V fixture from a 277V (60Hz) branch circuit
- 20 amp minimum. Transformer is rated for 277V primary. 1.1 amp, 120V
secondary, 300W maximum incandescent load. One transformer can be used
to supply one or more fixtures, not to exceed the 300W total load.
2. Wire Leads: 4' long, 18 ga., SF1 wire leads provided. Flexible conduit
shown in insert detail, by others.
3. End Cover: Aluminum, 16 ga.
4. Connector: 3/8" connector provided for attaching flexible conduit
(by others).
5. Mounting Brackets: Adjustable 16 ga. steel, uses standard 3/4" or 1 1/2"
lathing channels (by others) or Lightolier mounting bars.
Electrical
Transformer Characteristics
Lamp Wattage Secondary Voltage Total Input Wattage
75W 119V 78W
100W 118V 104W
150W 117V 157W
200W 116V 207W
300W 115V 300W
Options & Accessories
Mounting Bars: 1950-18” Set of (2)
1951-18” Set of (2)
T-Bar Anchor Clips: 1956-Set of (4), for use with above
Labels
U.L. (Suitable for Damp Locations), Union Made
Access above ceiling required.