P
READANDUNDERSTANDTHESEINSTRUCTIONSBEFOREINSTALLINGFIXTURE
Thisfixtureisintendedfor installation in aczordan~ with the National Electrical Code and local regulations,
To assure full compliance with local codes and regulations, check with your local electrical inspector before
Installation, Toprevent electrical shock, turnoff electricity at fuse box before proceeding.
Retainthese instructions for maintenancereference,
CONDUIT ADAPTER
FOR USE WITH BASIC LYTESPAN”TRACK SYSTEM ONLY.
The CONDUIT ADAPTER is used for power feed10theLIVE END of Basic
Lytespanfromsurfaceconduitthatterminatesin 1/2-14 IPSthreadedconnector.
CAUTiON:
“ TURNOFFPOWERAT FUSE BOX BEFOREInstalling
TRACK.
“ usEoNLY #12 GA, soLIDcoPPER wlREIN connectors To
MAINTAiN PROPERRATiNGOFTRACK,
OBSERVEPOLARITY,WHITE(NEUTRAL)WIRE MUSTBE
o
CONNECTEDTO TERMINAL MARKED“NEUT”, FAILURETO
OBSERVEPOLARiTY MAY RESULTINAN ELECTRICAL
HAZARD,
~ DO NOT USETRACK AS A CONDUITSUPPORT,
INDEPENDENTCONDUITSUPPORTS(SUCHAS SUiTABLE
CONDUITSTRAPS)MUST BEUSEDTOATTACH THECONDUIT
lNSTALLATiONTOTHE BUILDINGSTRUCTURE,
BOTTOM->
COVER
FIG, 1
3
INSTRUCTION SHEET NO,
IS:7596
R0892
PLUG
INSTALLATION FORBASICLYTESPAN
l, UnscrewPLUGandremoveBOTTOMCOVERfromLIVEEND(Fig,l),
2,ScrewinCONDUlTADAPTER(Fig,2),
3,Screweleckimlconnector(byothers)intoCONDUITADAPTER,Passsupplyleads
throughassemblyandfastensupplyIeadsasshown
NOTES:TheNUTinside the LIVE END can be rotated to permit
sufficient clearance for suppiy leads. CONDUITADAPTER is NOT
required for Advent Lytespanm,
ontrackinstructionsheet1S:6020,
FIG. 2
[m I <> H
iC> L I E H