Lightolier 7480 User Manual

READ AND UNDERSTAND ALL TRACK, CONNECTOR, FEED-IN-KITS, AND ACCESSORY
INSTRUCTION SHEETS BEFORE INSTALLING ANY TRACK ITEM.
This fixture is intended for installation in accordance with the National Electrical Code and local or Federal code specifications. To assure full compliance with codes and regulations, check with your local electrical inspector before installation. To prevent electric shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
INSTRUCTION SHEET NO.
IS:7480
B1197 Page 1 of 2
Installation Instructions for Swivel Stem Mounting Kits
for use with Lytespan and ProSpec
Caution:
Turn off power at fuse box before installing track.
Instructions for grounding must be followed. Failure to do
so may result in a hazardous condition.
• Do not supply Advent Track from two separate 120V branch circuits as this could overload the neutral track conductor leading to an electrical safety hazard.
Observe polarity, white (neutral) wire must be connected to terminal marked "NEUT". Failure to observe Polarity may result in an electrical hazard.
Swivel Stem mounting kits (0-90 deg., 48" long), for use in sloped ceilings, may be attached to the track at any point and may be spaced up to 4' apart. They are also used to feed power to the track: use the stem closest to the track feed-in point. The unthreaded end of the stem may be field cut using a hacksaw or similar cutting devise. The Stem Extension Kit (48") is used to lengthen a stem (this stem cannot be field cut).
A. FASTEN NON-POWER FEED STEMS TO CEILING
1. Mark centerline for track through center of outlet box.
2. Thread Mounting Screws into Stem Mounting Plates (Fig. C). Remove green screw and washer from Non-Power Feed Stems. Fasten Stem Mounting Plates to ceiling, either to building structure or with permanent fasteners capable of supporting at least 50 lbs. each. Space Stems no more than 4' apart. (See Fig. A.)
3. Attach all Stems which do not carry Supply Leads as follows: Slide Upper Swivel Housing over Swivel Casting Assembly and
attach to Neck Wireway. (See Fig. C). Drive Longer Set Screw into Upper Swivel Housing and through
hole in front of casting until you engage the hole in Neck Wireway. Place Canopy over Swivel Casting Assembly and Mounting Screws. (See Fig. C).
Secure with Cap Screws until Canopy rests tightly against ceiling. Slide Stem into Swivel Casting Assembly and drive Set Screw through hole in the side of casting. Slide Lower Casting Assembly.
Drive Set Screw into Lower Swivel Housing and through the hole in the front of casting until Stem is held tight. Assembly Track Clamps using Flat Head Screws. Screw Track Clamps onto bottom of Stem. (See Figs B and E.)
B. Fasten Power Feed Stem to Outlet Box
1. Outlet Box must be capable of supporting a maximum weight of 50 pounds. Power Feed Stem must be adjacent to track feed-in point. Note: Wires cannot pass beneath two stems.
2. Thread Mounting Screws into Stem Mounting Plate (Fig. Cc).
3. Pass Supply Leads (#12 AWG solid TW wires supplied by others) through Swivel Casting Assembly. Leave at least 6" of Supply Lead
Track Systems Only.
3" or 4" octagonal outlet box (by others)
Fig. A
Side of Casting
Set Screw
Flat Head Screws
Track Clamps
Fig. B
Ground Spring
Neck Wireway
Upper Swivel
Swivel Casting
Assembly
Cap Screws
Fig. C
Housing
Canopy
6"
4' Max.
Centerline
Stem Mounting Plate
Canopy
Upper Swivel Housing
Swivel Casting Assembly
Lower Swivel Housing
Stem
Supply Leads (#12 Solid TW wire supplied by others)
Outlet Box Wirenuts Ground Wire Stem Mounting
Plate Mounting
Screws Longer Set
Screw Outlet Box
Screws Front of
Casting Supply Leads
(#12 solid TW Wires by others)
Lower Swivel Housing
Stem
FALL RIVER, MASSACHUSETTS 02720 MONTREAL, QUEBEC, CANADA
© 1997
INSTRUCTION SHEET NO.
Installation Instructions for Stem Mounting Kit
IS:7480
B1197 Page 2 of 2
for splicing, and enough wire to run horizontally along upper section of track to power feed-in point, plus additional wire for attaching to power feed connections. Slide Upper Swivel Housing over Supply Leads and Swivel Casting Assembly. Feed Supply Leads through Neck Wireway. Attach Upper Swivel Housing and Swivel Casting Assembly to Neck Wireway, by driving Longer Set Screw into Upper Swivel Housing and through the hole in the front of the casting until you engage the hole in the Neck Wireway. (Fig. C).
4. Splice Supply Leads to branch circuit wiring in outlet box. White to white, black to black (red to red in Advent). Attach 12 AWG Branch Circuit ground wire between washer and green screw on Mounting Plate. (Fig. C.)
5. Fasten Stem Mounting Plate to Outlet Box with Outlet Box Screws. Place Canopy over assembly and Mounting Screws. Secure with Cap Screws until Canopy rest tight against ceiling.
6. Pass supply leads through unthreaded end of stem. Slide stem into Swivel casting Assembly and drive Set Screw through hole on the side of casting until tight. Slide Lower Swivel Housing over Stem and onto Swivel Casting Assembly. Drive Set Screw into Lower Swivel Housing and through hole in the front of casting until Stem is held tight.
7. Drive Flat Head Screws into Track Clamps. Screw Track Clamps onto bottom of Stem. (See Figs. C and E.)
C. Mounting Track Units onto Stems
1. Loosen Screws on Track Clamps. For feed stem, the Track Clamp must be positioned as shown in Fig.D-1. Place Track Ribs (Fig. D-3) between Track lamps and slide track into position. Make sure Bead (Fig. D-3) of Track Units are in-line with one another when using more than one Track Unit..
2. Run Supply Leads along top of track toward Live End. Loosed screw in Live End and remove from track.
3. Cut Wireway Cover to distance from Track Clamp to end of Track Unit. Slide Wireway Cover into track over Supply Leads. (Fig. D-1, D3).
4. Remove Bottom Cover from Live End.
5. Break off Barrier in Live End by bending it back and forth. (Fig. D-2)
6. Pass Supply Leads through Barrier opening in Live End. Insert Live End into Track Unit and tighten Screw. For ProSpec feed track place wire cover into track before attaching the stems to the track unit.
7. Connect Supply Leads to screw terminals as shown in Instruction Sheet IS:6020, IS:6121, for Advent, or IS:26000, IS:26046, IS:26050 for ProSpec. Ground terminal in Live End is not used when feeding power from a Stem.
8. Fasten Bottom Cover to Live End. Tighten Screws on all Track Clamps.
for use with Lytespan and ProSpec
Center Barrier Broken Off
Live End
Supply Leads
Bottom Cover
Fig.D-1
Live End
Bottom Cover
Feed Track
Screw
Center Barrier
Sidewall
Barrier
ProSpec Track
Track Systems Only.
Wireway Cover
Track Clamp
Track Unit
Track Rib
Wireway Cover
Basic Track
Track Rib
Individual Track Unit
Screw
Wireway Cover
Advent Track
Barrier
Wireway Cover Track Rib
Fig. D-3Fig. D-2
Stem
Screw
Track Rib
Bead
Bead
Bead
D. Instructions for Stem Extension Kits
1. Screw Coupling to threaded end of Stem supplied with Stem Mounting Kit (Fig. E).
2. Screw Stem supplied with Stem Extension Kit to Coupling (Fig. E).
3. Complete installation of Stem Mounted Lytespan Track following steps in B.