Lightolier 6790BK226U User Manual

14"
4"
6
1
2
3
5
4
7
Decorative Opalite
6790BK226U
Page 1 of 2 Ceiling or Wall Mounted Compact Fluorescent
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902
Features
1. Diffuser: Injection molded white translucent polycarbonate diffuser.
2. Mounting: Twist-lock fastening system.
3. Ceiling Pan: 20 ga. die formed steel.
4. Lamps: Compact Fluorescent (by others)
5. Auxiliary Mounting Holes: For direct mounting to ceiling surface.
6. Insulation Pad: 1” thick fiberglass
7. Keyhole Mounting Slots: (4) For direct mounting to 3” or 4” octagonal out-
let boxes.
Lamping
Compact fluorescent: 26W Quad tube 4-Pin
General Electric Osram/Sylvania Philips F26DBXT4/SPX*/4P CF 26DD/E/* PL-C26W/*/4P
*Manufacturers’ color temperature designation.
Electrical
Lampholders: Compact Fluorescent: 4-pin, G24q -3 base Ballast: Electronic
120/277V Total Input Watts 53 Max. Line Current (Amps) .46/.21 Power Factor .98 Ballast Factor 1.0 THD < 10% Min. Starting Temps. -20°C (-4°F)
Ordering Information
Catalog Number Diameter Depth Finish Lamp
6790BK226U 14” 4” Gloss Black (2) 26W Quad Tube 4-Pin
Labels
UL Listed, Suitable for Damp Locations.
CERTIFIED TEST REPORT NO. 0971FR
COMPUTED BY LSI PROGRAM **TEST-LITE**
LIGHTOLIER SURFACE UTILITY FLOURESCENT
CAT. 6790BK226U WITH TWIST LOCK LEXAN DIFFUSER
2-26W QUAD TUBE GE LAMPS. LUMEN RATING = 1700 LMS.
ROBERTSON BALLAST #PSM226CQMVW, 120VAC
SPACING RATIO = 1.3
ROOM CAVITY RATIO
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
80 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .37 .35 .33 .35 .34 .32 .32 .31 .30 .30 .29 .28 .27.26 .26 .24 2 .32 .29 .27 .30 .28 .26 .28 .26 .24 .26 .24 .23 .24 .23 .21 .20 3 .28 .25 .22 .27 .24 .22 .25 .22 .20 .23 .21 .19 .21 .19 .18 .17 4 .25 .21 .19 .24 .21 .18 .22 .19 .17 .20 .18 .16 .19 .17 .16 .14 5 .22 .19 .16 .21 .18 .16 .19 .17 .15 .18 .16 .14 .17 .15 .13 .12 6 .19 .16 .14 .19 .16 .13 .17 .15 .13 .16 .14 .12 .15 .13 .11 .11 7 .17 .14 .12 .17 .14 .12 .16 .13 .11 .14 .12 .10 .13 .11 .10 .09 8 .16 .13 .10 .15 .12 .10 .14 .11 .10 .13 .11 .09 .12 .10 .09 .08 9 .14 .11 .09 .14 .11 .09 .13 .10 .08 .12 .10 .08 .11 .09 .08 .07
10 .13 .10 .08 .12 .10 .08 .12 .09 .07 .11 .09 .07 .10 .08 .07 .06
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
C
ANDLEPOWER DATA
ANGLE CANDLEPOWER LUMENS 0 286 5 286 28 10 284 15 281 80 20 276 25 269 125 30 260 35 249 156 40 235 45 221 171 50 204 55 185 166 60 164 65 143 142 70 120 75 97 103 80 75 85 58 66
ANGLE CANDLEPOWER LUMENS 90 48 95 46 51 100 45 105 44 47 110 44 115 42 42 120 41 125 39 35 130 37 135 34 27 140 31 145 29 19 150 26 155 23 11 160 20 165 17 5 170 13 175 11 2 180 10
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 231 6.80 18.23 0-40 386 11.38 30.53 0-60 723 21.27 57.04 0-90 1032 30.37 81.47 40-90 645 18.99 50.94 60-90 309 9.11 24.43 90-180 234 6.91 18.53 0-180 1267 37.29 100.00 ** EFFICIENCY = 32.6% **
Decorative Opalite
6790BK226U
Page 2 of 2 Ceiling or Wall Mounted Compact Fluorescent
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902
80
70
60
50
40
INITIAL FOOTCANDLES
30
20
10
20 40 60 80 100 120
3 4 5 6 7 8 9 10 11
Use quick calculator chart to determine the number and spacing of luminaries for a desired level of illumination.
AREA PER FIXTURE IN SQUARE FEET
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
2 Light - 26W Quad Tube
1800 Lumens Per Lamp
RCR = 1 (60' x60'x8.5' room) RCR = 5 (12' x12'x8.5' room) RCR = 10 (6' x6'x8.5' room) Room surface reflectances 80% Ceiling,50% Walls,20% Floor
150 120
180
100
200
300
0
ACROSS 45 ALONG
90
80
30