Decorative Lumiquad
2 5/8"
10 5/16"
Sqr.
1
2
3
4
5
6
™
6783WH213N1
Page 1 of 2 Ceiling or Wall Mounted Compact Fluorescent
Ceiling Pan Only
Ordering Information
Catalog Number Finish Ballast
6783WH213N1 Matte White Magnetic NPF 120V
6783BZ213N1 Matte Bronze Magnetic NPF 120V
Features
1. Diffuser: Injection molded white translucent Polycarbonate.
2. Screw: Diffuser removal, tamper proof.
3. Ballast: Magnetic NPF 120V.
4. Ceiling Pan: 16 ga. die formed aluminum
5. Lamps: Compact fluorescent (by others).
6. Mounting: K.O.’s for direct mounting to 3” or 4” octagonal junction boxes.
Lamping
Compact Fluorescent: (2)13W Twin Tube 2-Pin
General Electric Osram/Sylvania Philips
F13BX/SPX* CF 13DS/* PL-S13W/ *
*Manufacturers’ color temperature designation.
13W lamp rated to start at 32°F.
Electrical
Lampholders: Compact Fluorescent: 2-pin, GX23 base
Ballast: Magnetic 120V
Total Input Watts 28
Max. Line Current (Amps) .72
Power Factor Normal
Ballast Factor .8
THD < 10%
Min. Starting Temps. 0°C (32°F)
Labels
UL Listed, Suitable for Wet Locations.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 Genlyte Group LLC • C0406
Decorative Lumironde
™
6783WH213N1
Page 2 of 2 Ceiling or Wall Mounted Compact Fluorescent
60
50
40
30
INITIAL FOOTCANDLES
20
10
5 10 15 20 25 30 35 40 45 50 55
AREA PER FIXTURE IN SQUARE FEET
2 3 4 5 6 7
Use quick calculator chart to determine the number and spacing of luminaries for
a desired level of illumination.
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
2 Light - 13W Twin Tube
900 Lumens Per Lamp
RCR = 1 (60' x60'x8.5' room)
RCR = 5 (12' x12'x8.5' room)
RCR = 10 (6' x6'x8.5' room)
Room surface reflectances
80% Ceiling,50% Walls,20% Floor
SPACING RATIO = 1.3
CERTIFIED TEST REPORT NO. 0980FR
COMPUTED BY LSI PROGRAM **TEST-LITE**
LIGHTOLIER SURFACE UTILITY FLOURESCENT, LUMIRONDE
CAT. 6731BK213N1 WITH LEXAN DIFFUSER
2-ROBERTSON BALLASTS #S1P, 120VAC
C
ANDLEPOWER DATA
ANGLE CANDLEPOWER LUMENS
0 131
5 131 13
10 130
15 128 37
20 125
25 122 57
30 117
35 111 70
40 105
45 98 76
50 89
55 80 72
60 70
65 59 59
70 48
75 36 39
80 25
85 16 19
90 11
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 104 6.55 22.84
0-40 174 10.91 38.06
0-60 321 20.10 70.10
0-90 436 27.29 95.16
40-90 262 16.38 57.10
60-90 115 7.19 25.06
90-180 22 1.39 4.84
0-180 458 28.68 100.00
** EFFICIENCY = 28.7% **
150 120
180
40
80
120
0
2-13W TWIN TUBE SYL. LAMPS (DULUX S). LUMEN RATING = 800 LMS.
ACROSS
45
ALONG
90
80
30
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
ANGLE CANDLEPOWER LUMENS
95 8 10
100 7
105 6 7
110 5
115 4 4
120 3
125 2 2
130 1
135 1 1
140 1
145 1 1
150 1
155 1 1
160 1
165 1 1
170 1
175 1 1
180 1
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
80 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .29 .28 .27 .29 .28 .26 .27 .26 .25 .26 .25 .24 .25 .24 .23 .23
2 .26 .24 .22 .25 .23 .22 .24 .22 .21 .23 .21 .20 .22 .21 .20 .19
3 .23 .20 .18 .22 .20 .18 .21 .19 .18 .20 .18 .17 .19 .18 .17 .16
4 .20 .18 .16 .20 .17 .15 .19 .17 .15 .18 .16 .15 .17 .16 .14 .14
5 .18 .15 .13 .17 .15 .13 .17 .15 .13 16 .14 .13 .15 .14 .12 .12
6 .16 .13 .12 .16 .13 .11 .15 .13 .11 .14 .12 .11 .14 .12 .11 .10
7 .14 .12 .10 .14 .12 .10 .13 .11 .10 .13 .11 .09 .12 .11 .09 .09
8 .13 .10 .09 .13 .10 .09 .12 .10 .08 .12 .10 .08 .11 .09 .08 .08
ROOM CAVITY RATIO
9 .12 .09 .08 .11 .09 .08 .11 .09 .07 .11 .09 .07 .10 .08 .07 .07
10 .11 .08 .07 .10 .08 .07 .10 .08 .07 .10 .08 .06 .09 .08 .06 .06
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
Job Information Type:
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 Genlyte Group LLC • C0406