Lightolier 6750 User Manual

11" Dia
3
1
2
4
5
6
11" Dia
3 7/8"
1 1/2"
1 1/2"
3 7/8"
Decorative Lumidisc
6750
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902
Features
1. Ceiling Pan: Die-formed 16 ga. aluminum.
2. Diffuser: Injection molded white translucent acrylic with twist-lock fasten-
ing feature.
3. Insulation Pad: 1” Thick fiberglass.
4. Lamp Socket: Electronic Ballast: (2) 4-pin G24q-1 base.
Magnetic Ballast: (2) 2-pin GX23-2 base
5. Ballast: See Electrical/Ballast. Magnetic: (2) one lamp, encased and potted, NPF, class “P”, sound rated
“A”, UL listed for Type 1 outdoor. Electronic: (1) two lamp, encased, class “P”, sound rated “A”, UL listed for Type 1 outdoor.
6. Keyhole Mounting Slots: (4) for direct mounting to 3” or 4” octagonal out­let box.
Electrical/Ballast
13W 13W Magnetic (NPF) Electronic
120V 120V 277V Total Input Watts 36 30 30 Max. Line Current (Amps) .75 .25 .11 Power Factor N > .97 >.97 Ballast Factor 1.0 >0.98 >0.98 THD < 15% < 10% <10% Min. Starting Temps. 0°C (32°F) 18°C (0°F) 18°C (0°F)
Ordering Information:
Cat. No. Diameter Depth Finish Voltage Lamps
6750WH213U 11” 3 7/8” Gloss Electronic (2) 13W Quad Tube 4-Pin (G24q-1 base)
White 120/277V General Electric Osram/Sylvania Philips
F13DBX/SPX*/4P CF13DD/E/* PL-C13W/*/4P
6750WH213N1 11” 3 7/8” Magnetic NPF (2) 13W Quad Tube 2-Pin (GX23-2 base)
120V General Electric Osram/Sylvania Philips
F13DBX23T4/SPX* CF13DD/* PLC13W/*/USA *Manufacturers’ color temperature designation.
Labels
UL Listed for Damp Locations, and 90°C supply conductors.
Electronic
Magnetic
CERTIFIED TEST REPORT NO. 0978FR
COMPUTED BY LSI PROGRAM **TEST-LITE**
LIGHTOLIER SURFACE UTILITY FLUORESCENT, LUMIDISC
WITH TWIST LOCK ACRYLIC DIFFUSER
2-13W QUAD TUBE GE LAMPS. LUMEN RATING = 900 LMS.
ESI BALLAST #ES-2/1-CFQ-13/10-UNVD,120VAC
SPACING RATIO = 1.4
ROOM CAVITY RATIO
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
80 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .32 .31 .29 .31 .29 .28 .28 .27 .26 .26 .25 .24 .24 .23 .23 .22
2 .28 .25 .23 .27 .25 .23 .25 .23 .21 .23 .21 .20 .21 .20 .19 .18
3 .24 .22 .19 .23 .21 .19 .22 .19 .18 .20 .18 .17 .18 .17 .16 .15
4 .21 .19 .16 .21 .18 .16 .19 .17 .15 .18 .16 .14 .16 .15 .14 .13
5 .19 .16 .14 .18 .16 .14 .17 .15 .13 .16 .14 .12 .15 .13 .12 .11
6 .17 .14 .12 .16 .14 .12 .15 .13 .11 .14 .12 .11 .13 .11 .10 .09
7 .15 .12 .10 .15 .12 .10 .14 .11 .10 .13 .11 .09 .12 .10 .09 .08
8 .14 .11 .09 .13 .11 .09 .12 .10 .08 .11 .09 .08 .11 .09 .08 .07
9 .12 .10 .08 .12 .09 .08 .11 .09 .07 .10 .08 .07 .10 .08 .07 .06
10 .11 .09 .07 .11 .08 .07 .10 .08 .06 .10 .08 .06 .09 .07 .06 05
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
CANDLEPOWER DATA
ANGLE CANDLEPOWER LUMENS 0 131 5 130 12 10 130 5 129 36 20 127 25 124 57 30 120 35 115 72 40 109 45 102 79 50 95 55 86 77 60 77 65 67 67 70 57 75 47 50 80 37 85 29 33 90 24
ANGLE CANDLEPOWER LUMENS 95 23 25 100 22 105 21 22 110 20 115 19 19 120 18 125 17 15 130 16 135 14 11 140 12 145 10 6 150 8 155 6 3 160 4 165 3 1 170 2 175 1 0 180 1
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 105 5.88 18.07 0-40 177 9.88 30.33 0-60 334 18.56 57.00 0-90 483 26.87 82.52 40-90 305 16.99 52.19 60-90 149 8.31 25.52 90-180 102 5.69 17.48 0-180 586 32.56 100.00
** EFFICIENCY = 32.6% **
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
Decorative Lumidisc
6750
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902
Job Information Type:
60
50
40
30
INITIAL FOOTCANDLES
20
10
5 10 15 20 25 30 35 40 45 50 55
AREA PER FIXTURE IN SQUARE FEET
2 3 4 5 6 7
Use quick calculator chart to determine the number and spacing of luminaries for a desired level of illumination.
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
2 Light - 13W Quad Tube
860 Lumens Per Lamp
RCR = 1 (60' x60'x8.5' room) RCR = 5 (12' x12'x8.5' room) RCR = 10 (6' x6'x8.5' room) Room surface reflectances 80% Ceiling,50% Walls,20% Floor
180
40
80
120
0
150 120
ACROSS 45 ALONG
90
30
80