Lightolier 6422MC User Manual

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
INSTRUCTIONS FOR ATTACHING LYTESPOT®TO LYTESPAN®TRACK
For use with Lytespan®Track Systems Only
INSTRUCTIONS FOR ATTACHING LYTESPOT®TO SINGLE CIRCUIT TRACK SYSTEMS
1. Insert into LYTESPAN TRACK. (Fig. 1) LOCKING LEVER must be on the same side of track as BEAD.
2. Rotate FITTING clockwise until LOCKING LEVER snaps and locks in place. (Fig. 2 & 3)
3. To remove: depress LOCKING LEVER, then rotate FITTING 90° counterclockwise.
LYTESPAN TRACK
INSTRUCTION SHEET NO.
I S : 6 4 2 2 M C
0498 Page 1 of 2
BEAD
FITTING
LOCKING
LEVER
Fig. 1
INSTRUCTIONS FOR CONVERTING LYTESPOT
®
ATTACHMENT FITTINGS TO OPERATE ON 2 CIRCUIT TRACK
See Fig. 4. BRASS CONTACTcan be raised or lowered. Broken line indicates position for 1 circuit or lower circuit of 2 circuit track system.
To convert attachment FITTING for upper circuit of 2 circuit track, raise BRASS CONTACT to high position by lifting CONTACT as high as stop permits and CONTACT clicks into place.
Fig. 2 Fig. 3
BRASS CONTACT
LOCKING LEVER
Fig. 4
LIGHTOLIER a GENLYTE company.
631 Airport Road, Fall River, MA 02720
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
WARNING: LIGHT FIXTURE and L A M P get extremely
hot during operation. Allow FIXTURE to cool before handling.
INSTRUCTION SHEET NO.
I S : 6 4 2 2 M C
0498 Page 2 of 2
INSTRUCTIONS FOR LAMPING (Fig. 5 & 6)
1. Remove LOUVER by pulling straight out. (Fig. 5)
2. WARNING: RISK OF FIRE
Use only T-4 Tungsten – Halogen outside frosted minican base L A M P, 150 watts maximum. Insert L A M P into S O C K E T. Turn clockwise until tight. To remove, turn counterclockwise. (Fig. 6)
3. Replace LOUVER with GLASS LAMP GUARD in place by pushing straight up until LOUVER is flush with FIXTURE HOUSING.
WA R N I N G: Lamp manufacturers require the
GLASS LAMP GUARD be in place before energizing L A M P, and that great care should be taken that LAMP is fully cooled before relamping.
HOUSING
GLASS LAMP
GUARD
Fig. 5
LOUVER
HOUSING
T-4 LAMP
Fig. 6
SOCKET
LIGHTOLIER a GENLYTE company.
631 Airport Road, Fall River, MA 02720