INSTRUCTION SHEET NO. ‘
INSTRUCTIONS FOR AITACHING LYTESPOT” TO
LYTESPAN” TRACK
IS:6210
R0490
FOR USE WITH BASIC OR ADVENT LYTESPAN TRACK SYSTEMS ONLY.
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE.
This fixture is intended for installation in accordance with the National Code and local regulations. To
assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
INSTRUCTIONS FOR ATTACHING LYTESPOT TO
SINGLE CIRCUIT TRACK SYSTEMS
1.
Align BEAD on LYTESPAN TRACK and GROOV’E in
FITTING before inserting into LYTESPAN TRACK.
See Fig. 1. (if BEAD is NOT aligned, a potential
hazard may result. )
,,~
GROOVE
FITTING
/- LYTESPAN TRACK
LEVER
2.
Position LEVER as shown in
To attach FITTING, insert into LYTESPAN TRACK.
3.
Fig. 1.
Turn LEVER 90° to make mechanical and electrical
connection. See Fig. 2.
To remove or shift fixture location on the LYTESPAN
4.
TRACK, reverse procedure as described in #3 above.
NOTE:
“Burn
not porcelain, sockets are used.
Lamp manufacturers’ bulb sleeve may state
only in porcelain sockets.” In certain fixtures phenolic,
These are of a special heat
resistant type that have been tested, by Lightolier and are listed
by Underwriters Laboratories for use with the recommended lamps.
INSTRUCTIONSFOR CONVERTINGLYTESPOT
ATTACHMENTFITTING TO OPERATEON
2 CIRCUITTRACKSYSTEMS
NOTE; TO insure proper operation of Lytespots on TM
Circuit Lytespan Track, the BLACK SPACER (provided)
must be used at all times on the plug assembly.
The BLACK SPACER is not used when operating Lytespots
on Single Circuit Track.
%
&
MOVABLE BRASS
CONTACT
*
FIG. 1
FIG. 2
BLACK
SPACER
o
FIG. 3
LOWER CIRCUIT, FIG. 3:
Illustrates contacts in low position with spacer in
place for lower circuit.
UPPER CIRCUIT, FIG. 4 and 5:
To convert attachment fitting for upper circuit, raise
BRASS CONTACT to high position (as indicated by
dotted line) by pulling CONTACT as high as stop
permits and slipping on BLACK SPACER as shown in
Fig. 4 and 5.
b
PLUG
ASSEM8L
BLACK
SPACER
-----
0 ----
%*
‘1
MOVABLE
8RASS
CONTACT
:- ~
---
FIG. 4
STATIONARY
CONTACT
(Comm.n)
BLACK
S PACER
0
FIG. 5