Lightolier 5533 User Manual

5
6
7
8
9
10
1
3
2
4
16 13/16" Dia.
4 3/8"
Decorative Spill Ring
5533
Job Information Type:
Job Name: Cat. No.:
Lamp(s): Notes:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 Genlyte Group LLC • B0305
Features
1. Ceiling Pan: Die-formed 16 ga. aluminum.
2. Trim Ring:Formed 16 ga. aluminum.
3. Knob: (3) Turned brass.
4. Diffuser: Formed white translucent acrylic.
5. Mounting Holes: (3) 3/16" Dia., 120° apart on a 3” Dia. Bolt circle.
6. Lamp Socket: See Lamps.
7. Ballast: See Electrical/Ballast
8. Keyhole Mounting Slots: (2) for direct mounting to 4” octagonal outlet box. †9.Emergency Lighting: Add suffix E
(See Specification Sheet SU-EM)
10.Lamps: 26W Compact Fluorescent Quad Tube (by others).
Electrical/Ballast
Electronic 120/277V Total Input Watts 53 Max. Line Current (Amps) .46 /.21 Power Factor > .98 Ballast Factor 1.0 THD < 10% Min. Starting Temps. -20°C (-4°F)
Ordering Information:
Cat. No. Finish Lamps Diameter Depth
(2) 26 W Quad Tube 4-Pin (G24q-3 base)
5533PB226U Polished brass General Electric Osram/Sylvania Philips 16-13/16” 4-3/8” 5533SN226U Satin Nickel F26DBXT4/SPX */4P CF26DD/E/ * PL-C 26W/ * /4P 16-13/16” 4-3/8” 5533WH226U Gloss White * Manufacturers’ color temperature designation. 16-13/16” 4-3/8”
Labels
UL Listed Suitable for Damp Locations. †UL Listed, (for Indoor Dry Locations only).
CERTIFIED TEST REPORT NO. 1104FR
COMPUTED BY LSI PROGRAM **TEST-LITE**
LIGHTOLIER SURFACE UTILITY FLOURESCENT SPILL RING
CAT.# 5533WH226U WITH ENCLOSED ACRYLIC DIFFUSER
2-26W DULUX D\E SYL.LAMPS. LUMEN RATING = 1800 LMS.
ROBERTSON BALLAST #PSM226CQMVW,120VAC
CANDLEPOWER DATA
ANGLE CANDLEPOWER LUMENS 0 402 5 401 39 10 396 15 388 110 20 377 25 363 168 30 346 35 326 205 40 304 45 281 217 50 255 55 227 205 60 200 65 175 174 70 150 75 127 136 80 106 85 86 94 90 66
ANGLE CANDLEPOWER LUMENS 95 52 58 100 40 105 30 32 110 22 115 18 18 120 15 125 13 12 130 11 135 10 8 140 9 145 9 6 150 8 155 8 4 160 7 165 6 2 170 5 175 5 1 80 5
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
ROOM CAVITY RATIO
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
80 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .41 .39 .37 .40 .38 .36 .37 .36 .34 35 .34 .33 .33 .32 .31 .30 2 .36 .33 .30 .35 .32 .30 .32 .30 .28 .31 .29 .27 .29 .27 .26 .25 3 .31 .28 .25 .30 .27 .25 .29 .26 .24 .27 .25 .23 .25 .23 .22 .21 4 .28 .24 .21 .27 .24 .21 .26 .23 .20 .24 .22 .20 .23 .21 .19 .18 5 .25 .21 .18 .24 .21 .18 .23 .20 .17 .22 .19 .17 .20 .18 .16 .15 6 .22 .18 .16 .22 .18 .15 .20 .17 .15 .19 .17 .15 .18 .16 .14 .13 7 .20 .16 .14 .19 .16 .13 .18 .15 .13 .17 .15 .13 .17 .14 .12 .11 8 .18 .14 .12 .17 .14 .12 .17 .14 .11 .16 .13 .11 .15 .13 .11 .10 9 .16 .13 .10 .16 .13 .10 .15 .12 .10 .14 .12 .10 .14 .11 .10 .09
10 .15 .11 .09 .14 .11 .09 .14 .11 .09 .13 .11 .09 .13 .10 .08 .08
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 315 8.77 21.29 0-40 520 14.45 35.10 0-60 941 26.14 63.50 0-90 1343 37.33 90.68 40-90 823 22.88 55.58 60-90 402 11.19 27.18 90-180 138 3.84 9.32 0-180 1481 41.16 100.00 ** EFFICIENCY = 41.2% **
SPACINGRATIO= 1.3
Decorative Spill Ring
5533
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 Genlyte Group LLC • B0305
Job Information Type:
50 70 60 50 40 30 20
INITIAL FOOTCANDLES
10
20 40 60 80 100 120
3 4 5 6 7 8 9 10 11
Use quick calculator chart to determine the number and spacing of luminaries for a desired level of illumination.
AREA PER FIXTURE IN SQUARE FEET
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
2 Light - 26W Quad Tube
1800 Lumens Per Lamp RCR = 1 (60' x60'x8.5' room)
RCR = 5 (12' x12'x8.5' room) RCR = 10 (6' x6'x8.5' room) Room surface reflectances 80% Ceiling,50% Walls,20% Floor
150 120
180
200
400
600
0
ACROSS 45 ALONG
90
80
30
Loading...