Lightolier 5230 User Manual

5
6
7
8
9
1
2
3
4
10
15 3/8" Dia.
16 1/4" Dia.
3 5/8"
4 5/8"
Decorative Lumidrum
Page 1 of 2 Ceiling or Wall Mounted Compact Fluorescent
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902
Features
1. Ceiling Pan: Die-formed 16 ga. aluminum.
2. Diffuser: Formed white translucent acrylic.
3. Bracket: (2) Twist-lock fastener.
4. Stop: (2) Formed 18 ga. galvanized steel.
5. Mounting Holes: (3) 3/16" Dia., 120° apart on a 14 1/8" Dia. Bolt circle.
6. Lamp Socket: See Lamps.
7. Ballast: See Electrical/Ballast
8. Keyhole Mounting Slots: (2) For direct mounting to 4” octagonal outlet box. †9. Emergency Lighting: Add suffix E (See Specification Sheet SU-EM)
10. Lamps: (by others)
Electrical/Ballast
Electronic 120/277V Total Input Watts 53 Max. Line Current (Amps) .46 / .21 Power Factor >.98 Ballast Factor 1.0 THD <10% Min. Starting Temps. -20°C (-4°F)
Ordering Information
Cat. No. Finish Lamps (by others) Diameter Depth
5230WH226U Gloss White (2) 26 W Quad Tube 4-Pin (G24q-3 base) 16 1/4” 4 5/8”
General Electric Osram/Sylvania Philips
F26DBXT4/SPX */4P CF26DD/E/ * PL-C26W/*/4P *Manufacturers’ color temperature designation.
Label:
UL Listed, suitable for Damp Locations. †UL Listed, (for Indoor Dry Locations only).
US Patent Pending.
CERTIFIED TEST REPORT NO. 1044FR
COMPUTED BY LSI PROGRAM **TEST-LITE**
LIGHTOLIER SURFACE UTILITY FLOURESCENT LUMIDOME
CAT. 5231WH226U WITH TWIST ACRYLIC DIFFUSER
2-26W QUAD TUBE SYL.LAMPS. LUMEN RATING = 1800 LMS.
ROBERTSON BALLAST #PSM226CQMVW, 120VAC
ATING = 1160 LMS.
ROBERTSON BALLAST #RED1L10-120R, 120VAC
CANDLEPOWER DATA
ANGLE CANDLEPOWER LUMENS
0 450 5 448 43 10 443 15 434 123 20 422 25 407 189 30 388 35 367 230 40 342 45 317 246 50 291 55 263 236 60 235 65 209 208 70 183 75 59 169 80 136 85 115 126 90 93
ANGLE CANDLEPOWER LUMENS
95 79 86 100 64 105 52 56 110 42 115 35 36 120 30 125 26 24 130 25 135 24 19 140 24 145 23 15 150 23 155 23 11 160 23 165 23 7 170 21 175 19 2 180 21
TESTED ACCORDING TO IES
PROCEDURES. TEST DISTANCE EXCEEDS
FIVE TIMES THE GREATEST LUMINOUS
OPENING OF LUMINAIRE.
ROOM CAVITY RATIO
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
80 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .50 .47 .45 .48 .46 .43 .44 .42 .41 .41 .40 .38 .38 .37 .36 .34
2 .43 .39 .36 .41 .38 .35 .38 .36 .33 .36 .34 .31 .33 .31 .30 .28 3 .37 .33 .30 .36 .32 .29 .34 .30 .28 .31 .29 .26 .29 .27 .25 .24 4 .33 .29 .25 .32 .28 .25 .30 .27 .24 .28 .25 .23 .26 .24 .22 .20 5 .30 .25 .22 .29 .24 .21 .27 .23 .20 .25 .22 .19 .23 .21 .19 .17 6 .26 .22 .19 .26 .21 .18 .24 .20 .18 .22 .19 .17 .21 .18 .16 .15 7 .24 .19 .16 .23 .19 .16 .21 .18 .15 .20 .17 .14 .19 .16 .14 .13 8 .21 .17 .14 .21 .17 .14 .19 .16 .13 .18 .15 .13 .17 .14 .12 .11
9 .20 .15 .12 .19 .15 .12 .18 .14 .12 .17 .14 .11 .16 .13 .11 .10 10 .18 .14 .11 .17 .13 .11 .16 .13 .10 .15 .12 .10 .14 .12 .10 .09 DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHEDPROCEDURES
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 353 9.82 19.44 0-40 583 6.21 32.09 0-60 1064 29.58 58.56 0-90 1565 43.49 86.10 40-90 982 27.28 54.02 60-90 500 13.92 27.55 90-180 252 7.02 13.90 0-180 1818 50.51 100.00 ** EFFICIENCY = 50.5% **
SPACING RATIO = 1.3
Decorative Lumidrum
Page 2 of 2 Ceiling or Wall Mounted Compact Fluorescent
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902
Job Information Type:
80
70
60
50
40
INITIAL FOOTCANDLES
30
20
10
20 40 60 80 100 120 140 180
3 4 5 6 7 8 9 10 11 12 13
Use quick calculator chart to determine the number and spacing of luminaries for a desired level of illumination.
AREA PER FIXTURE IN SQUARE FEET
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
2 Light - 26W Quad Tube
1800 Lumens Per Lamp
RCR= 1 (60' x60'x8.5' room) RCR=5 (12' x12'x8.5' room) RCR= 10 (6' x6'x8.5' room) Room surface reflectances 80% Ceiling,50% Walls,20% Floor
180
200
400
600
0
150 120
ACROSS 45 ALONG
90
60
30
Loading...