Lightolier 4R35 User Manual

3/8"
Nominal OAL
7 11/16"
35"
7"
Architectural Decorative 4R35
Page 1 of 2 Pendalux Traditional 35" Diameter Body 6-26/32/42 Triple Tube
°
45
Max.
2
Note: Drawing illustrates only one of the suspension types available for this luminaire. For other drawings, consult indi­vidual Suspension Specification Sheet numbers as noted in Suspension chart(s) below.
4
5
6
3
7
1
Complete Luminaire Consists of Body and Suspension: Order Each Separately.
Body Cat. No. Finish Lamps Options
4R35642APBU Polished Brass 6-26 Triple Tube Compact Fluorescent D2 (26W, 120V only), 4R35642ASBU Satin Brass or 6-32 Triple Tube Compact Fluorescent E3 (347V), or EM
or 6-42 Triple Tube Compact Fluorescent Add Suffix to Cat. No.
Single Swivel Stem Multiple to Short Swivel Stem 3 Rods to Short Swivel Suspension Ext. Kits
Cat. No. Nominal OAL Cat. No. Nominal OAL Cat. No. Nominal OAL Cat. No. Nominal OAL Specify Finish as Suffix: Specify Finish as Suffix: Specify Finish as Suffix: Specify Finish as Suffix:
PB or SB PB or SB PB or SB PB or SB 4SB115 16 9/16” 4ST228 29 3/8” 4ST435 35” 4SXT48 48”
4SB118 18” (close-to-ceiling) 4ST235 33 See Specification Sheet 4ST428 4SXT96 96” 4SB121 19 5/16” 4ST242 40 5/16” 4SB124 25 9/16” 4SB128 29 3/8” 4SB135 35” 4SB142 40 5/16”
See Specification Sheet(s) 4SB115, 4SB124
See Specification sheet 4ST228
Specifications
Suspension Size:
all length) in pr tion length (see shaded cells). OAL is defined from bottom of diffuser to ceil­ing plane.
• Stem Wires: Equipped with 120” of leads with keyed connectors for quick
connection to Body wiring.
For optimum per
tion to the Body diameter or for close-to-ceiling propor-
opor
mance testing r
for
ecommends OAL (over
Options & Accessories
D2 = Dimming Electronic Ballast, 26 Watt, 120V, only.
Replace Body Cat No. Suffix “U” with Suffix “D2”.
E3
= 347V (Canada)
Replace Body Suf
EM
= Emergency Battery Pack
Add Suffix “EM” to Body Cat. No. Multi-Level Switching: Fusing: Consult Factor Finishes: PB = Polished Brass, SB = Satin Brass
fix “U” with Suf
ed, consult wiring diagram.
ewir
Pr
.
y
fix “E3”.
-
Job Information Type:
Job Name:
.:
No
t.
Ca
Lamp(s):
Notes:
Lightolier a Genlyte company www.lightolier.com
631 Airpor We reserve the right to change details of design, materials and finish. © 2006 Genlyte Gr
t Road, Fall River
, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
oup LLC • B0406
Architectural Decorative 4R35
Page 2 of 2 Pendalux Traditional 35" Diameter Body 6-26/32/42 Triple Tube
Features
1. Diffusing Reflector: White translucent acrylic, 3/16” thick.
2. Inner Dirt Shield: White translucent acrylic, 1/8” thick.
3. Chassis: Steel 20 gauge, semi-gloss white powder-coat finish.
4. Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, steel, 7” Dia.
fastened internally, no exposed hardware. Permits installation on ceilings with slope of up to 45°. Complies with California Code.
5. Rods: Reflector Bowl is suspended from a central point on three 3/16” steel
rods.
6. Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4
lamp base.
7. Flange Trim: Steel 20 gauge, Plated or Painted finish.
Lamping (by others)
Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.
General Electric Osram/Sylvania Philips
26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F26TBX/*/A/4P CF26DT/E/IN/* PL-T26W/*/4P
riple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
32W T F32TBX/*/A/4P CF32DT/E/IN/* PL-T32W/*/4P
42W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F42QBK/*/A/4P CF42DT/E/IN/* PL-T42W/*/4P
*Manufacturers’ color temperature designation.
Electrical
Ballast: Electronic, 2-Lamp HPF, Class P, Programmed Start. Universal Voltage
120/277V, Multi-Wattage 26/32/42W.
6 Lamp 26 Watt 32Watt 42Watt Voltage 120V 277V 120V 277V 120V 277V Total Input Watts 168 168 210 210 279 279 Max. Line Current
(amps)
2.22 0.96 1.40 2.80 1.20 1.60
Power Factor >0.98 >0.98 >0.98 >0.98 >0.99 >0.99 Ballast Factor 1.02 1.02 0.96 0.96 0.95 0.95
THD <10% Minimum Starting Temperature: -5˚F/-20˚C
Mounting
Mounts directly to 4” outlet box, using crossbar hanger, supplied.
Labels
cULus Suitable for Damp Locations.
Application Data
35 Inch Diameter 36’ x 36’ x 11’ Space
TTT
1.15
Spacing: 12’ x 12’ Susp. Dist. 35”
TTT
1.42
TTT
1.94
e
Luminair
2 Lamps 26W 32W 42W
Illum. (FC) Maint. 28 37 49 Lum.Ratio 8/1 8/1 8/1
atts/Sq. Ft.
W Reflectancies: 80% Ceiling, 50% Walls, 20% Floor.
Light Loss Factor = .75 (.88 BF x .85) FC (footcandles) at 30” work plane.
CERTIFIED TEST REPORT NO. 4R35642A
COMPUTED BY LSI PROGRAM **TEST-LITE**
LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE
CAT. #4R35642SNU, 35” DIFFUSER
6-42W T/E SYLVANIA LAMPS. LUMEN RATING = 3200 LMS.
3-ADVANCE BALLAST #ICF-2S42-M2-LD, 120 VAC
ANGLE MEAN CP LUMENS 0 495 5 497 47 10 490 15 480 136 20 468 25 450 208 30 430 35 404 253 40 373 45 340 263 50 304 55 268 240 60 231 65 190 190 70 154 75 118 126 80 85 85 56 68 90 44
DATE: MAR. 1, 2001
ARED FOR:
PREP
ALL RIVER, MA
LIGHTOLIER, F
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
ZONE LUMENS% LAMP%LUMINAIRE 0-30 424 2.22 3.23 0-40 699 3.64 5.31 0-60 1246 6.48 9.47 0-90 1659 8.64 12.62 40-90 60-90 90-180 12631 65.79 95.98 0-180 14269 74.43 100.00
CANDLEPOWER SUMMARY
ZONAL LUMENS AND PERCENTAGES
1069 5.01 7.31
414 2.16 3.15
** EFFICIENCY = 74.4% **
ANGLE MEAN CP LUMENS
90 44
95 235 347 100 757 105 1311 1339 110 1681 115 1932 1913 120 2163 125 2341 2083 130 2442 135 2546 1973 140 2654 145 2727 1707 150 2764 155 2785 1290 160 2818 165 2679 750 170 2401 175 2363 231 180 2540
80 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .58 .55 .53 .51 .49 .46 .37 .36 .35 .24 .24 .23 .13 .12 .12 .08 2 .51 .47 .43 .44 .41 .38 .32 .30 .28 .21 .20 .19 .11 .10 .10 .07 3 .45 .40 .36 .35 .35 .32 .29 .26 .24 .19 .17 .16 .10 .09 .09 .06 4 .39 .34 .31 .34 .30 .27 .25 .22 .20 .17 .15 .14 .09 .08 .07 .05 5 .34 .30 .26 .31 .26 .23 .22 .20 .17 .15 .13 .12 .08 .07 .06 .04 6
.31 .26 .22
.27 .23 .20 .20 .17 .15 .13 .12 .10 .07 .06 .06 .04 7 .28 .23 .19 .24 .20 .17 .18 .15 .13 .12 .10 .09 .06 .05 .05 .03 8 .25 .20 .17 .22 .18 .15 .16 .13 .11 .11 .09 .08 .06 .05 .04 .03 9
.22 .18 .14
.20 .16 .13
.15 .12 .10
.10 .08 .07 .05 .04 .04 .02
10 .20 .16 .13 .18 .14 .11 .13 .11 .09 .09 .07 .06 .05 .04 .03 .02
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
ob Information Type:
J
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 Genlyte Group LLC • B0406