Architectural Decorative 4K35
Page 1 of 2 Pendalux Contemporary 35" Diameter Body 6-26/32/42 Triple Tube
7”
45°
Max.
6
2
Note: Drawing illustrates only one of the suspension types available for this luminaire. For other drawings, consult individual Suspension Specification Sheet numbers as noted in Suspension chart(s) below.
Complete Luminaire Consists of Body and Suspension: Order Each Separately.
4
5
1
3
35”
1 3/8”
Body Cat. No. Finish Lamps Options
4K35642ASBU Satin Brass 6-26 Triple Tube Compact Fluorescent D2 (26W, 120V only), 4K35642ASNU Satin Nickel or 6-32 Triple Tube Compact Fluorescent E3 (347V), or EM 4K35642AWHU White or 6-42 Triple Tube Compact Fluorescent Add Suffix to Cat. No.
7
Nominal OAL
7 11/16”
Single Swivel Stem Multiple to Short Swivel Stem 3 Cables to Short Swivel Suspension Ext. Kits
Cat. No. Nominal OAL Cat. No. Nominal OAL Cat. No. Nominal OAL Cat. No. Nominal OAL
Specify Finish as Suffix: Specify Finish as Suffix: Specify Finish as Suffix: Specify Finish as Suffix: SB, SN or WH SB, SN or WH SB, SN or WH SB, SN or WH
4SB115 16 9/16” 4SB224 25 9/16” 4SB335 35” 4SXT48 48” 4SB118 18”(close-to-ceiling) 4SB228 29 3/8” See Specification Sheet 4SB324 4SXT96 96” 4SB121 19 5/16” 4SB235 35” 4SB124 25 9/16” 4SB242 40 5/16” 4SB128 29 3/8” See Specification sheet 4SB224 4SB135 35” 4SB142 40 5/16”
See Specification Sheet(s) 4SB115, 4SB124
Specifications
• Suspension Size: For optimum performance testing recommends OAL (over­all length) in proportion to the Body diameter or for close-to-ceiling propor­tion length (see shaded cells).OAL is defined from bottom of diffuser to ceil-
ing plane.
• Stem Wires: Equipped with 120” of leads with keyed connectors for quick connection to Body wiring.
Options & Accessories
D2 = Dimming Electronic Ballast, 26 Watt, 120V, only.
Replace Body Cat No. Suffix “U” with Suffix “D2”.
E3 = 347V (Canada)
Replace Body Suffix “U” with Suffix “E3”. EM = Emergency Battery Pack Add Suffix “EM” to Body Cat. No. Multi-Level Switching: Prewired, consult wiring diagram. Fusing: Consult Factory Finishes: SB = Satin Brass, SN = Satin Nickel, WH = White
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • D0808
Lightolier is a Philips group brand
Architectural Decorative 4K35
Page 2 of 2 Pendalux Contemporary 35" Diameter Body 6-26/32/42 Triple Tube
Features
1. Diffusing Reflector: White translucent acrylic, 3/16” thick.
2. Inner Dirt Shield: White translucent acrylic, 1/8” thick.
3. Chassis: Steel 20 gauge, semi-gloss white powder-coat finish.
4. Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, steel, 7” Dia.
fastened internally, no exposed hardware. Permits installation on ceilings with slope of up to 45°. Complies with California Code.
5. Cables: Reflector Bowl is suspended from a central point on three 1/16”
stainless steel cables.
6. Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4
lamp base.
7. Flange Trim: Steel 20 gauge, Plated or Painted finish.
Lamping (by others)
Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts. General Electric Osram/Sylvania Philips
26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F26TBX/*/A/4P CF26DT/E/IN/* PL-T26W/*/4P 32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F32TBX/*/A/4P CF32DT/E/IN/* PL-T32W/*/4P 42W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F42QBK/*/A/4P CF42DT/E/IN/* PL-T42W/*/4P
*Manufacturers’ color temperature designation.
Electrical
Ballast: Electronic, 2-Lamp HPF, Class P, Programmed Start. Universal Voltage
120/277V, Multi-Wattage 26/32/42W.
6 Lamp 26 Watt 32Watt 42Watt Voltage 120V 277V 120V 277V 120V 277V Total Input Watts 168 168 210 210 279 279 Max. Line Current
(amps)
2.22 0.96 2.80 1.20 1.20 1.60
Power Factor >0.98 >0.98 >0.98 >0.98 >0.99 >0.99 Ballast Factor 1.02 1.02 0.96 0.96 0.95 0.95
THD <10% Minimum Starting Temperature: -5˚F/-20˚C
Mounting
Mounts directly to 4” outlet box, using crossbar hanger, supplied.
Labels
cULus Suitable for Damp Locations.
Application Data
36’ x 36’ x 11’ Space
Luminaire Spacing: 12’ x 12’
Susp. Dist. 35”
2 Lamps 26W 32W 42W TTT TTT TTT Illum. (FC) Maint. 28 37 49 Lum.Ratio 8/1 8/1 8/1 Watts/Sq. Ft. 1.15 1.42 1.94
35 Inch Diameter
CERTIFIED TEST REPORT NO. 4R35642A
COMPUTED BY LSI PROGRAM **TEST-LITE**
LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE
CAT. #4R35642SNU, 35” DIFFUSER
6-42W T/E SYLVANIA LAMPS. LUMEN RATING = 3200 LMS.
3-ADVANCE BALLAST #ICF-2S42-M2-LD, 120 VAC
CANDLEPOWER SUMMARY
Angle Mean CP Lumens 0 495 5 497 47 10 490 15 480 136 20 468 25 450 208 30 430 35 404 253 40 373 45 340 263 50 304 55 268 240
60 231
65 190 190 70 154 75 118 126 80 85 85 56 68 90 44
ZONAL LUMENS AND PERCENTAGES
DATE: MAR. 1, 2001 PREPARED FOR: LIGHTOLIER, FALL RIVER, MA
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
ZONE LUMENS % LAMP %LUMINAIRE 0-30 424 2.22 3.23 0-40 699 3.64 5.31 0-60 1246 6.48 9.47 0-90 1659 8.64 12.62 40-90 1069 5.01 7.31 60-90 414 2.16 3.15 90-180 12631 65.79 95.98 0-180 14269 74.43 100.00
** EFFICIENCY = 74.4% **
Angle Mean CP Lumens 90 44 95 235 347 100 757 105 1311 1339 110 1681 115 1932 1913
120 2163
125 2341 2083 130 2442 135 2546 1973 140 2654 145 2727 1707 150 2764 155 2785 1290 160 2818 165 2679 750 170 2401 175 2363 231 180 2540
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
80 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .58 .55 .53 .51 .49 .46 .37 .36 .35 .24 .24 .23 .13 .12 .12 .08
2 .51 .47 .43 .44 .41 .38 .32 .30 .28 .21 .20 .19 .11 .10 .10 .07
3 .45 .40 .36 .35 .35 .32 .29 .26 .24 .19 .17 .16 .10 .09 .09 .06
4 .39 .34 .31 .34 .30 .27 .25 .22 .20 .17 .15 .14 .09 .08 .07 .05
5 .34 .30 .26 .31 .26 .23 .22 .20 .17 .15 .13 .12 .08 .07 .06 .04
6 .31 .26 .22 .27 .23 .20 .20 .17 .15 .13 .12 .10 .07 .06 .06 .04
7 .28 .23 .19 .24 .20 .17 .18 .15 .13 .12 .10 .09 .06 .05 .05 .03
ROOM CAVITY RATIO
8 .25 .20 .17 .22 .18 .15 .16 .13 .11 .11 .09 .08 .06 .05 .04 .03
9 .22 .18 .14 .20 .16 .13 .15 .12 .10 .10 .08 .07 .05 .04 .04 .02
10 .20 .16 .13 .18 .14 .11 .13 .11 .09 .09 .07 .06 .05 .04 .03 .02
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
Reflectancies: 80% Ceiling, 50% Walls, 20% Floor. Light Loss Factor = .75 (.88 BF x .85) FC (footcandles) at 30” work plane.
Lightolier is a Philips group brand
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • G0808