Lightolier 4F28 User Manual

Architectural Decorative 4F28
Page 1 of 2 Pendalux Gemini 28” Diameter Body 4-26/32/42 Triple Tube
Job Information Type:
Job Name: Cat. No.:
Lamp(s): Notes:
Lightolier a Genlyte company www.lightolier.com
Specifications
• Suspension Size: For optimum performance testing recommends OAL
(overall length) in proportion to the Body diameter or for close-to-ceiling pro­portion length (see shaded cells). OAL is defined from bottom of diffuser to ceiling plane.
• Stem Wires: Equipped with 120” of leads with keyed connections for quick
connection to Body wiring.
Options & Accessories
D2 = Dimming Electronic Ballast, 26 Watt, 120V, only
Replace Body Cat No. Suffix “U” with Suffix “D2”.
E3 = 347V (Canada)
Replace Body Suffix “U” with Suffix “E3”.
EM = Emergency Battery Pack
Add Suffix “EM” to Body Cat. No.
Multi-Level Switching: Prewired, consult wiring diagram.
Finishes: PB = Polished Brass, SN = Satin Nickel, WH = White
Complete Luminaire consists of Body and Suspension: Order each separately.
Body Cat. No. Finish Lamps Options
4F28442APBU Polished Brass 4-26 Triple Tube Compact Fluorescent D2 (26W, 120V only), 4F28442ASNU Satin Nickel or 4-32 Triple Tube Compact Fluorescent E3 (347V) 4F28442AWHU White or 4-42 Triple Tube Compact Fluorescent Add Suffix to Cat. No.
45° Max.
7"
Nominal OAL
1 3/8"
6 1/8"
28"
3
6
2
1
5
4
7
Note: Drawing above illustrates only one of the sus­pension types available for this Luminaire. For other drawings, consult individual Suspension Specification Sheet numbers as noted in Suspension chart(s) below.
Single Swivel Stem Multiple to Short Swivel Stem 3 Cables to Short Swivel Suspension Ext. Kits
Cat. No. Nominal OAL Cat. No. Nominal OAL Cat. No. Nominal OAL Cat. No. Nominal OAL
Specify Finish as Suffix: Specify Finish as Suffix: Specify Finish as Suffix: Specify Finish as Suffix: PB, SN or WH PB, SN or WH PB, SN or WH PB, SN or WH
4SB115 15” (close-to-ceiling) 4SB224 24” 4SB328 27 13/16” 4SXT48 48” 4SB118 16 7/16” 4SB228 27 3/16” See Specification Sheet 4SB324 4SXT96 96” 4SB121 17 3/4” 4SB235 33 7/16” 4SB124 24” 4SB242 38 3/4” 4SB128 27 3/16” See Specification sheet 4SB324 4SB135 33 7/16” 4SB142 38 3/4”
See Specification Sheet(s) 4SB115, 4SB124
Features
1. Diffusing Reflector: White translucent acrylic, 3/16” thick.
2. Inner Dirt Shield: White translucent acrylic, 1/8” thick.
3. Chassis: Steel 20 gauge, semi-gloss white powder-coat finish.
4. Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, steel, 7” Dia.
fastened internally, no exposed hardware. Permits installation on ceilings with slope of up to 45°. Complies with California Code.
5. Multiple Stems: 3/8” Steel outer pipe stems surround center stem and go
into collector plate.
6. Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or
GX24q-4 lamp base.
7. Flange Trim: Steel 20 gauge, Plated or Painted Finish.
Lamping (by others)
Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.
General Electric Osram/Sylvania Philips
26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F26TBX/*/A/4P CF26DT/E/IN/* PL-T26W/*/4P
32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F32TBX/*/A/4P CF32DT/E/IN/* PL-T32W/*/4P
42W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F42QBK/*/A/4P CF42DT/E/IN/* PL-T42W/*/4P
*Manufacturers’ color temperature designation.
Electrical
Ballast: Electronic, 2-Lamp HPF, Class P, Programmed Start.
Universal Voltage 120/277V, Multi-Wattage 26/32/42W.
4 Lamps 26 Watt 32Watt 42Watt
Voltage 120V 277V 120V 277V 120V 277V Total Input Watts 110 110 136 136 186 186 Max. Line Current (amps) 1.11 0.48 1.40 0.60 0.60 0.80 Power Factor >0.98 >0.98 >0.98 >0.98 >0.99 >0.99 Ballast Factor 1.02 1.02 0.96 0.96 0.95 0.95 THD<10% Minimum Starting Temperature -5°F /-20°C.
Mounting
Mounts directly to 4” outlet box, using crossbar hanger, supplied.
Labels
cULus listed suitable for damp locations.
Application Data
Reflectancies: 80% Ceiling, 50% Walls, 20% Floor. Light Loss Factor = .75 (.88 BF x .85) FC (footcandles) at 30” work plane.
28 Inch Diameter 30’ x 30’ x 10’ Space Luminaire Spacing: 10’ x 10’
Susp. Dist. 28”
4 Lamps 26W 32W 42W
TTT TTT TTT Illum. (FC) 30 41 54 Maint. Lum. 8/1 8/1 9/1 Ratio Watts/ 1.10 1.36 1.86 Sq. Ft.
ANGLE MEAN CP LUMENS
90 53
95 121 199 100 433 105 834 871 110 1193 115 1470 1453 120 1722 125 1912 1704 130 2053 135 2149 1656 140 2203 145 2215 1386 150 2192 155 2178 1005 160 2136 165 1949 546 170 1666 175 1624 159 180 1756
CERTIFIED TEST REPORT NO. 4A28442A
COMPUTED BY LSI PROGRAM **TEST-LITE**
LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE
CAT. #4A28442APBU, HOUSING COVER WITHOUT FLANGE, 28” DIFFUSER
4-42W PLT TRIPLE TUBE PHILIPS LAMPS. LUMEN RATING = 3200 LMS.
2-ADVANCE BALLAST, #ICF-2S42-M2-LD, 120 VAC
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
ZONE LUMENS% LAMP%LUMINAIRE 0-30 311 2.43 3.03 0-40 512 4.01 5.00 0-60 920 7.20 8.97 0-90 1287 10.06 12.54 40-90 774 6.05 7.55 60-90 366 2.86 3.57 90-180 8978 70.15 87.46 0-180 10266 80.21 100.00
** EFFICIENCY = 80.2% **
CANDLEPOWER SUMMARY
ANGLE MEAN CP LUMENS
0 395
5 394 38 10 389 15 382 108 20 372 25 360 166 30 342 35 321 201 40 297 45 272 211 50 247 55 221 198 60 193 65 165 165 70 141 75 116 123 80 92 85 71 78 90 53
ROOM CAVITY RATIO
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
80 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .68 .65 .63 .60 .57 .54 .44 .42 .41 .29 .28 .27 .15 .15 .14 .08
2 .59 .55 .51 .52 .48 .45 .38 .35 .33 .25 .24 .22 .13 .13 .12 .07
3 .52 .47 .42 .46 .41 .37 .33 .30 .28 .22 .21 .19 .12 .11 .10 .06
4 .46 .40 .36 .40 .35 .32 .30 .26 .24 .20 .18 .16 .10 .10 .09 .05
5 .40 .35 .30 .36 .31 .27 .26 .23 .20 .18 .15 .14 .09 .08 .08 .04
6 .36 .30 .26 .32 .27 .23 .24 .20 .17 .16 .14 .12 .08 .07 .07 .04
7 .32 .26 .22 .28 .23 .20 .21 .18 .15 .14 .12 .10 .08 .06 .06 .03
8 .38 .29 .19 .26 .21 .17 .19 .16 .13 .13 .11 .09 .07 .06 .05 .03
9 .36 .26 .17 .23 .18 .15 .17 .14 .11 .12 .09 .08 .06 .05 .04 .02
10 .33 .24 .15 .21 .16 .13 .16 .12 .10 .11 .08 .07 .06 .05 .04 .02
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
ZONAL LUMENS AND PERCENTAGES
Architectural Decorative 4F28
Page 2 of 2 Pendalux Gemini 28” Diameter Body 4-26/32/42 Triple Tube
Lightolier a Genlyte company www.lightolier.com
Job Information Type: