Lightolier 4A35 User Manual

7"
1 3/8"
Nominal OAL
7 1/2"
35"
3
5
2
1
4
Architectural Decorative 4A35
45
°
Max.
Page 1 of 2 Pendalux Cirrus 35” Diameter Body 6-26/32/42 Triple Tube
Note: Drawing above illustrates only one of the suspension types available for this lumi­naire. For other drawings, consult individual Suspension Specification Sheet numbers as noted in Suspension chart(s) below.
Complete Luminaire consists of Body and Suspension: Order each separately.
Body Cat. No. Finish Lamps Options
4A35642APBU Polished Brass 6-26 Triple Tube Compact Fluorescent D2 (26W, 120V only), 4A35642ASNU Satin Nickel or 6-32 Triple Tube Compact Fluorescent E3 (347V), or EM
or 6-42 Triple Tube Compact Fluorescent Add Suffix to Cat. No.
Single Swivel Stem Multiple Swivel Stem Suspension Extension Kits
Cat. No. Nominal OAL Cat. No. Nominal OAL Cat. No. Nominal OAL Specify Finish as Suffix: PB or SN Specify Finish as Suffix: PB or SN Specify Finish as Suffix: PB or SN 4SB115
4SB118 18” (close-to-ceiling) 4SB228 29 3/8” 4SXT96 96” 4SB121 19 5/16” 4SB235 35” 4SB124 25 9/16” 4SB242 40 5/16” 4SB128 29 3/8” See Specification Sheet 4SB224. 4SB135 35” 4SB142 40 5/16”
See Specification Sheet(s) 4SB115, 4SB124
16 9/16” 4SB224 25 9/16” 4SXT48 48”
Specifications
• Suspension Size: For optimum performance testing recommends OAL (over-
all length) in pr tion length (see shaded cells). OAL is defined from bottom of diffuser to ceil­ing plane.
Stem W
connection to Body wiring.
Options & Accessories
D2 = Dimming Electronic Ballast, 26 Watt, 120V, only.
Replace Body Cat No. Suffix “U” with Suffix “D2”.
E3 = 347V (Canada)
Replace Body Suffix “U” with Suffix “E3”.
= Emergency Battery Pack
EM
Add Suffix “EM” to Body Cat. No. Multi-Level Switching: Fusing: Consult Factory Finishes: PB = Polished Brass, SN = Satin Nickel
oportion to the Body diameter or for close-to-ceiling propor-
es:
ir
Equipped with 120” of leads with keyed connectors for quick
Prewired, consult wiring diagram.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 Genlyte Gr
oup LLC • C0406
Architectural Decorative 4A35
Page 2 of 2 Pendalux Cirrus 35” Diameter Body 6-26/32/42 Triple Tube
Features
1. Diffusing Reflector: White translucent acrylic, 3/16” thick.
2. Inner Dirt Shield: White translucent acrylic, 1/8” thick.
3. Chassis: Steel, 20 gauge, semi-gloss white powder-coat finish.
4. Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, 7” Dia., fas-
tened internally, no exposed hardware. Permits installation on ceilings with slope of up to 45˚. Complies with California Code.
5. Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4
lamp base.
Lamping (by others)
Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.
General Electric Osram/Sylvania Philips
26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F26TBX/*/A/4P CF26DT/E/IN/* PL-T26W/*/4P
32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F32TBX/*/A/4P CF32DT/E/IN/* PL-T32W/*/4P
42W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F42QBK/*/A/4P
CF42DT/E/IN/* PL-T42W/*/4P
*Manufacturers’ color temperature designation.
Electrical
Ballast: Electronic, 2-Lamp HPF, Class P, Programmed Start. Universal Voltage
120/277V, Multi-Wattage 26/32/42W.
6 Lamp 26 Watt 32Watt 42Watt Voltage 120V 277V 120V 277V 120V 277V Total Input Watts 168 168 210 210 279 372 Max. Line Current (amps) 2.22 0.96 2.80 1.20 1.20 1.60 Power Factor >0.98 >0.98 >0.98 >0.98 >0.99 >0.99 Ballast Factor 1.02 1.02 0.96 0.96 0.95 0.95 THD<10% Minimum Starting Temperature: -5°F/-20°C
Mounting
Mounts directly to 4” outlet box, using crossbar hanger, supplied.
Labels
cULus listed suitable for damp locations.
Application Data
35 Inch Diameter 36’ x 36’ x 11’ Space Luminaire Spacing: 12’ x 12’
Susp. Dist. 35”
6 Lamps
26W TTT
32W
TTT TTT Illum. (FC) 33 44 58 Maint. Lum. 8/1 8/1 9/1 Ratio Watts/ 1.15 1.42 1.94 Sq. Ft.
Reflectances: 80% Ceiling, 50% Walls, 20% Floor. Light Loss Factor = .75 (.88 BF x .85) FC (footcandles) at 30” work plane.
42W
CERTIFIED TEST REPORT NO. 4A35642A
COMPUTED BY LSI PROGRAM **TEST-LITE**
LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE
CAT. #4A353642APBU, 35” DIFFUSER
6-42W T/E SYLVANIA LAMPS. LUMEN RATING = 3200 LMS.
3-ADVANCE BALLAST #ICF-2S42-M2-LD, 120 VAC
ANGLE 0 5 10 15 632 179 20 613 25 591 273 30 566 35 534 334 40 493 45 451 349 50 406 55 361 324 60 315 65 268 267 70 226 75 184 196 80 146 85 110 124 90 90
DATE: DEC. 14, 2000
ARED FOR:
PREP LIGHTOLIER, FALL RIVER, MA
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
ZONE 0-30 514 2.68 3.29 0-40 848 4.42 5.42 0-60 1520 7.92 9.72 0-90 2107 10.98 13.47 40-90 1259 6.56 8.05 60-90 587 3.06 3.75 90-180 13538 70.51 86.53 0-180 15646 81.49 100.00 ** EFFICIENCY = 81.5% **
CANDLEPOWER SUMMARY
MEAN CP LUMENS
655 653 62 645
ZONAL LUMENS AND PERCENT
LUMENS% LAMP%LUMINAIRE
ANGLE MEAN CP LUMENS 90 90 95 280 422 100 896 105 1385 1435 110 1760 115 2112 2095 120 2458 125 2759 2453 130 2960 135 3096 2391 140 3197 145 3262 2045 150 3303 155 3356 1548 160 3367 165 3147 882 170 2778 175 2734 268 180 2972
80 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .69 .66 .64 .61 .58 .55 .45 .43 .42 .30 .29 .28 .16 .16 .15 .08 2 .60 .56 .52 .53 .49 .46 .39 .36 .34 .26 .24 .23 .14 .13 .13 .07 3 .53 .48 .43 .47 .42 .38 .34 .31 .29 .23 .21 .20 .12 .11 .11 .06 4 .47 .41 .36 .41 .36 .32 .30 .27 .24 .20 .18 .17 .11 .10 .09 .05 5 .41 .35 .31 .37 .31 .27 .27 .23 .21 .18 .16 .14 .10 .09 .08 .04
VITY RATIO
.37 .31 .26 .33 .27 .23 .24 .21 .18 .16 .14 .12 .09 .08 .07 .04
6
CA
.33 .27 .23
7
ROOM
8 .30 .24 .20 .26 .21 .18 .19 .16 .13 .13 .11 .09 .07 .06 .06 .03
.27 .21 .17
9
.24 .19 .15
10
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
.29 .24 .20
.24 .19 .15 .18 .14 .12 .12 .10 .08 .07 .05 .05 .02 .22 .17 .14
.22 .18 .15
.16 .13 .10
.15 .12 .11
.11 .09 .07
.08 .07 .06
.06 .05 .04
AGES
.03
.02
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
ve the right to change details of design, materials and finish.
eser
e r
W © 2006 Genlyte Group LLC • C0406
Loading...