7"
1 3/8"
Nominal OAL
7 1/2"
35"
3
5
2
1
4
Architectural Decorative 4A35
Page 1 of 2 Pendalux Cirrus 35” Diameter Body 6-26/32/42 Triple Tube
Note: Drawing above illustrates only one of
the suspension types available for this luminaire. For other drawings, consult individual
Suspension Specification Sheet numbers as
noted in Suspension chart(s) below.
Complete Luminaire consists of Body and Suspension: Order each separately.
Body Cat. No. Finish Lamps Options
4A35642APBU Polished Brass 6-26 Triple Tube Compact Fluorescent D2 (26W, 120V only),
4A35642ASNU Satin Nickel or 6-32 Triple Tube Compact Fluorescent E3 (347V), or EM
or 6-42 Triple Tube Compact Fluorescent Add Suffix to Cat. No.
Single Swivel Stem Multiple Swivel Stem Suspension Extension Kits
Cat. No. Nominal OAL Cat. No. Nominal OAL Cat. No. Nominal OAL
Specify Finish as Suffix: PB or SN Specify Finish as Suffix: PB or SN Specify Finish as Suffix: PB or SN
4SB115
4SB118 18” (close-to-ceiling) 4SB228 29 3/8” 4SXT96 96”
4SB121 19 5/16” 4SB235 35”
4SB124 25 9/16” 4SB242 40 5/16”
4SB128 29 3/8” See Specification Sheet 4SB224.
4SB135 35”
4SB142 40 5/16”
See Specification Sheet(s) 4SB115, 4SB124
16 9/16” 4SB224 25 9/16” 4SXT48 48”
Specifications
• Suspension Size: For optimum performance testing recommends OAL (over-
all length) in pr
tion length (see shaded cells). OAL is defined from bottom of diffuser to ceiling plane.
Stem W
•
connection to Body wiring.
Options & Accessories
D2 = Dimming Electronic Ballast, 26 Watt, 120V, only.
Replace Body Cat No. Suffix “U” with Suffix “D2”.
E3 = 347V (Canada)
Replace Body Suffix “U” with Suffix “E3”.
= Emergency Battery Pack
EM
Add Suffix “EM” to Body Cat. No.
Multi-Level Switching:
Fusing: Consult Factory
Finishes: PB = Polished Brass, SN = Satin Nickel
oportion to the Body diameter or for close-to-ceiling propor-
es:
ir
Equipped with 120” of leads with keyed connectors for quick
Prewired, consult wiring diagram.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 Genlyte Gr
oup LLC • C0406
Architectural Decorative 4A35
Page 2 of 2 Pendalux Cirrus 35” Diameter Body 6-26/32/42 Triple Tube
Features
1. Diffusing Reflector: White translucent acrylic, 3/16” thick.
2. Inner Dirt Shield: White translucent acrylic, 1/8” thick.
3. Chassis: Steel, 20 gauge, semi-gloss white powder-coat finish.
4. Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, 7” Dia., fas-
tened internally, no exposed hardware. Permits installation on ceilings with
slope of up to 45˚. Complies with California Code.
5. Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4
lamp base.
Lamping (by others)
Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.
General Electric Osram/Sylvania Philips
26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F26TBX/*/A/4P CF26DT/E/IN/* PL-T26W/*/4P
32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F32TBX/*/A/4P CF32DT/E/IN/* PL-T32W/*/4P
42W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F42QBK/*/A/4P
CF42DT/E/IN/* PL-T42W/*/4P
*Manufacturers’ color temperature designation.
Electrical
Ballast: Electronic, 2-Lamp HPF, Class P, Programmed Start. Universal Voltage
120/277V, Multi-Wattage 26/32/42W.
6 Lamp 26 Watt 32Watt 42Watt
Voltage 120V 277V 120V 277V 120V 277V
Total Input Watts 168 168 210 210 279 372
Max. Line Current (amps) 2.22 0.96 2.80 1.20 1.20 1.60
Power Factor >0.98 >0.98 >0.98 >0.98 >0.99 >0.99
Ballast Factor 1.02 1.02 0.96 0.96 0.95 0.95
THD<10% Minimum Starting Temperature: -5°F/-20°C
Mounting
Mounts directly to 4” outlet box, using crossbar hanger, supplied.
Labels
cULus listed suitable for damp locations.
Application Data
35 Inch Diameter
36’ x 36’ x 11’ Space
Luminaire Spacing: 12’ x 12’
Susp. Dist. 35”
6 Lamps
26W
TTT
32W
TTT TTT
Illum. (FC) 33 44 58
Maint.
Lum. 8/1 8/1 9/1
Ratio
Watts/ 1.15 1.42 1.94
Sq. Ft.
Reflectances: 80% Ceiling, 50% Walls, 20% Floor.
Light Loss Factor = .75 (.88 BF x .85)
FC (footcandles) at 30” work plane.
42W
CERTIFIED TEST REPORT NO. 4A35642A
COMPUTED BY LSI PROGRAM **TEST-LITE**
LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE
CAT. #4A353642APBU, 35” DIFFUSER
6-42W T/E SYLVANIA LAMPS. LUMEN RATING = 3200 LMS.
3-ADVANCE BALLAST #ICF-2S42-M2-LD, 120 VAC
ANGLE
0
5
10
15 632 179
20 613
25 591 273
30 566
35 534 334
40 493
45 451 349
50 406
55 361 324
60 315
65 268 267
70 226
75 184 196
80 146
85 110 124
90 90
DATE: DEC. 14, 2000
ARED FOR:
PREP
LIGHTOLIER, FALL RIVER, MA
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
ZONE
0-30 514 2.68 3.29
0-40 848 4.42 5.42
0-60 1520 7.92 9.72
0-90 2107 10.98 13.47
40-90 1259 6.56 8.05
60-90 587 3.06 3.75
90-180 13538 70.51 86.53
0-180 15646 81.49 100.00
** EFFICIENCY = 81.5% **
CANDLEPOWER SUMMARY
MEAN CP LUMENS
655
653 62
645
ZONAL LUMENS AND PERCENT
LUMENS% LAMP%LUMINAIRE
ANGLE MEAN CP LUMENS
90 90
95 280 422
100 896
105 1385 1435
110 1760
115 2112 2095
120 2458
125 2759 2453
130 2960
135 3096 2391
140 3197
145 3262 2045
150 3303
155 3356 1548
160 3367
165 3147 882
170 2778
175 2734 268
180 2972
80 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .69 .66 .64 .61 .58 .55 .45 .43 .42 .30 .29 .28 .16 .16 .15 .08
2 .60 .56 .52 .53 .49 .46 .39 .36 .34 .26 .24 .23 .14 .13 .13 .07
3 .53 .48 .43 .47 .42 .38 .34 .31 .29 .23 .21 .20 .12 .11 .11 .06
4 .47 .41 .36 .41 .36 .32 .30 .27 .24 .20 .18 .17 .11 .10 .09 .05
5 .41 .35 .31 .37 .31 .27 .27 .23 .21 .18 .16 .14 .10 .09 .08 .04
VITY RATIO
.37 .31 .26 .33 .27 .23 .24 .21 .18 .16 .14 .12 .09 .08 .07 .04
6
CA
.33 .27 .23
7
ROOM
8 .30 .24 .20 .26 .21 .18 .19 .16 .13 .13 .11 .09 .07 .06 .06 .03
.27 .21 .17
9
.24 .19 .15
10
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
.29 .24 .20
.24 .19 .15 .18 .14 .12 .12 .10 .08 .07 .05 .05 .02
.22 .17 .14
.22 .18 .15
.16 .13 .10
.15 .12 .11
.11 .09 .07
.08 .07 .06
.06 .05 .04
AGES
.03
.02
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
ve the right to change details of design, materials and finish.
eser
e r
W
© 2006 Genlyte Group LLC • C0406