Architectural Decorative 4A23
Page 1 of 2 Pendalux Cirrus 23” Diameter Body 2-26/32/42 Triple Tube
7"
45ϒ
Max.
Note: Drawing above illustrates only one of the
suspension types available for this luminaire. For
other drawings, consult individual Suspension
Specification Sheet numbers as noted in
Suspension char t(s) below.
Complete Luminaire consists of Body and Suspension. Order each separately.
23 3/8"
Body Cat. No. Finish Lamps Options
4A23242APBU Polished Brass 2-26 Triple Tube Compact Fluorescent MX1 (26W, 120V only),
4A23242ASNU Satin Nickel or 2-32 Triple Tube Compact Fluorescent E3 (347V), or EM
or 2-42 Triple Tube Compact Fluorescent Add suffix to cat. no.
1 3/8"
Nominal OAL
6"
Single Swivel Stem Suspension Extension Kits
Cat. No. Nominal OAL Cat. No. Nominal OAL
Specify Finish as Suffix: PB or SN Specify Finish as Suffix: PB or SN
4SB115 15” (close-to-ceiling) 4SXT48 48”
4SB118 16 7/16” 4SX T96 96”
4SB121 17 3/4”
4SB124 24”
4SB128 27 13/16”
4SB135 33 7/16”
4SB142 38 3/4”
See Specification Sheet(s) 4SB115, 4SB124
Specifications
• SuspensionSize: For optimum performance testing recommends OAL
(overall length) in proportion to the Body diameter or for close-to-ceiling
proportion length (see spec sheet 4SB115 or 4SB124). OAL is defined from
bottom of diffuser to ceiling plane.
• StemWires: Equipped with 120” of leads with keyed connector for quick
connection to Body wiring.
Options & Accessories
MX1 = Dimming Electronic Ballast, 26 Watt, 120V, only
Replace Body Cat No. Suffix “U” with Suffix “MX1”.
E3 = 347V (Canada)
Replace Body Suf fix “U” with Suffix “E3”.
EM = Emergency Battery Pack
Add Suffix “EM” to Body Cat. No.
Multi-Level Switching: Prewired, consult wiring diagram.
Fusing: Consult Factor y
Finishes: PB = Polished Brass, SN = Satin Nickel
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • C0609

Architectural Decorative 4A23
Page 2 of 2 Pendalux Cirrus 23” Diameter Body 2-26/32/42 Triple Tube
Features
1. Diffusing Reflector: White translucent acrylic, 3/16” thick.
2. Inner Dirt Shield: White translucent acrylic, 1/8” thick.
3. Chassis: Steel, 20 gauge, semi-gloss white powder-coat finish.
4. Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, 7” Dia.,
fastened internally, no exposed hardware. Permits installation on ceilings
with slope of up to 45°. Complies with California Code.
5. Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4
lamp base.
Lamping (by others)
Compact Fluorescent: Triple Tube, 26, 32, or 42 Wat ts.
General Electric Osram/Sylvania Philips
26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F26TBX/*/A/4P CF26DT/E/IN/* PL-T26W/*/4P
32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F32TBX/*/A/4P CF32DT/E/IN/* PL-T32W/*/4P
42W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F42QBK/*/A/4P CF42DT/E/IN/* PL-T42W/*/4P
*Manufacturers’ color temperature designation.
Electrical
Ballast: Electronic, 2-Lamp HPF, Class P, Programmed Start. Universal Voltage
120/277V, Multi-Wattage 26/32/42W.
2 Lamp 26 Watt 32Watt 42Watt
Voltage 120V 277V 120V 277V 120V 277V
TotalInputWatt s 55 55 70 70 93 93
Max. Line Current (amps) 0.55 0.24 0.70 0.30 0.30 0.40
Power Factor >0.98 >0.98 >0.98 >0.98 >0.99 >0.99
Ballast Factor 1.02 1.02 0.96 0.96 0.95 0.95
THD<10% Minimum Starting Temperature: -5°F/-20°C
Mounting
Mounts directly to 4” outlet box, using crossbar hanger, supplied.
Labels
cULus Suitable for Damp Locations.
Application Data
23 Inch Diameter
24’ x 24’ x 9.5’ Space
Luminaire Spacing: 8’ x 8’
Susp. Dist. 24”
2 Lamps 26W 32W 42W
TTT TTT TTT
Illum. (FC) 22 29 40
Maint.
Lum. 7/1 7/1 8/1
Ratio
Watts/ 0.85 1.06 1.45
Sq. Ft.
CERTIFIED TEST REPORT NO. 4A23242A
COMPUTED BY LSI PROGRAM **TEST-LITE**
LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE
2-42W T/E SYLVANIA LAMPS. LUMEN RATING = 3200 LMS.
DATE: DEC. 11, 2000
PREPARED FOR:
LIGHTOLIER, FALL RIVER, MA
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
COEFFICIENTSOFUTILIZATIONZONALCAVITYMETHOD
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
CAT. #4A23242, 23” DIFFUSER
ADVANCE BALLAST #ICF-2S42-M2-LD, 120VAC
ANGLE MEAN CP LUMENS
0 195
5 193 18
10 191
15 189 53
20 184
25 177 82
30 169
35 158 99
40 148
45 137 106
50 126
55 113 101
60 100
65 88 87
70 76
75 64 68
80 53
85 42 47
90 38
ZONE LUMENS % LAMP %LUMINAIRE
0-30 153 2.40 2.95
0-40 252 3.95 4.86
0-60 459 7.18 8.83
0-90 661 10.34 12.72
40-90 409 6.39 7.86
60-90 202 3.16 3.88
90-180 4543 70.98 87.28
0-180 5204 81.33 100.00
CANDLEPOWERSUMMARY
ZONAL LUMENS AND PERCENTAGES
** EFFICIENCY = 81.3% **
ANGLE MEAN CP LUMENS
90 38
95 80 121
100 245
105 437 456
110 604
115 735 725
120 848
125 949 848
130 1035
135 1091 842
140 1133
145 1140 713
150 1125
155 1103 507
160 1051
165 956 267
170 812
175 647 65
180 598
80 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .69 .66 .63 .60 .58 .55 .44 .43 .41 .29 .28 .27 .15 .15 .15 .08
2 .60 .55 .51 .53 .49 .45 .38 .36 .34 .25 .24 .23 .13 .13 .12 .07
3 .53 .47 .43 .46 .42 .38 .34 .31 .28 .22 .21 .19 .12 .11 .10 .06
4 .47 .41 .36 .41 .36 .32 .30 .27 .24 .20 .18 .16 .11 .10 .09 .05
5 .41 .35 .30 .36 .31 .27 .27 .23 .20 .18 .16 .14 .09 .08 .08 .04
6 .37 .31 .26 .32 .27 .23 .24 .20 .18 .16 .14 .12 .08 .07 .07 .04
7 .33 .27 .22 .29 .24 .20 .21 .18 .15 .14 .12 .10 .08 .06 .06 .03
ROOM CAVITY RATIO
8 .30 .24 .20 .26 .21 .17 .19 .16 .13 .13 .11 .09 .07 .06 .05 .03
9 .27 .21 .17 .23 .19 .15 .17 .14 .12 .12 .10 .08 .06 .05 .04 .02
10 .24 .19 .15 .21 .17 .13 .16 .13 .10 .11 .08 .07 .06 .05 .04 .02
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
Reflectancies: 80% Ceiling, 50% Walls, 20% Floor.
Light Loss Factor = .75 (.88 BF x .85)
FC (footcandles) at 30” work plane.
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • C0609
Job Information Type: