Lightolier 412U User Manual

Specification Decorative Performance Pendalyte 412U
Page 1 of 6 12" Compact Fluorescent
Available with
Coil or Straight Cord
5 1/2”
(140mm)
Coil Cord
5-1/2”
(140mm)
Straight Cord
3/4”
(19mm)
3/4” (19mm)
Ordering Information: Complete fixture consists of: Power Head, Reflector, and Suspension System. Select each separately.
Power Head: Titanium Finish
Cat. No. Lamp Watts Volts Options
412U3 CFL Triple Tube 26/32/42 120/277 MX1, MX2, DA, E3 41270U CFL Triple Tube 70 120/277 MX1, MX2, E3 41285U CFL Triple Tube 85 120/277 Not App.
120” Max (3048mm)
5-1/2”
8-3/8”
3
2
22-1/4”
or
or
19-3/8”
1
Suspension
Cat. No. Color Description
4CCG Grey Coil Cord, 120” Length 4CCB Black Coil Cord, 120” Length 404SKG Grey Cable/Straight Cord, 120” Length 404SKB Black Cable/Straight Cord, 120” Length 404S36 Grey 36” Length 5/8” Stem 404S36B Black 36” Length 5/8” Stem 404S60 Grey 60” Length 5/8” Stem 404S60B Black 60” Length 5/8” Stem 404S120 Grey 120” Length 5/8” Stem
Optional Extension Kits
Cat. No. Color Description
404EXT300* Grey 25' Extension Cable/Cord Kit 404EXTB* Black 25' Straight Cable/Cord Extension Kit 404SG5** Grey 120" 5-wire Straight Cord 404SB5** Black 120" 5-wire Straight Cord 404EXT300G5** Grey 5-wire, 25’ Cord/Cable 404EXT300B5** Black 5-wire, 25’ Cord/Cable
* Use with Standard Suspension Kit. ** DALI requires a 5-wire Suspension, use with Standard Suspension Kit.
Reflector/Glass
Cat. No. Description
42SR Satin Aluminum Reflector 42WH White Glass 42BL Cobalt Blue Glass 42AB Amber Glass
Close to Ceiling Kits
Cat. No. Color Used With 4912CTCTM Titanium Standard 9" Pendalyte
and 12" Performance
Features
1. Reflector System: Reflector: High purity, 16 gauge aluminum. Exterior satined and anodized.
Interior low iridescent comfort clear anodized.
Glass Diffusers: Diffusers fabricated of pressed glass with soft etched exterior
and matte white interior fritt.
2. Power Head Housing: Two-piece extruded aluminum.
3. Suspension: Cable and Cord SJT18-3, Black or Grey. Canopy, 20 gage, .036 CRS.
Can be field shortened or 5/8” steel tubing and canopy with 35° swivel hanger.
Lamping (by others)
Compact Fluorescent:
General Electric Osram/Sylvania Philips
(1) 26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F26TBX/*/A/4P CF26DT/E/IN/* PL-T26W/*/4P
(1) 32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F32TBX/*/A/4P CF32DT/E/IN/* PL-T32W/*/4P
(1) 42W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F42QBX/*/A/4P CF42DT/E/IN/* PL-T42W/*/4P
(1) 57W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F57QBX/*/A/4P/EOL
(1) 70W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F70QBX/*/A/4P/EOL
(1) 85W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
N/A N/A PL-H85W/*/4P
* Manufacturers' color temperature designation.
CF57DT/E/IN/* N/A
CF70DT/E/IN/* N/A
26, 32, 42, 57 70W Triple Tube
13-13/16”
(351mm)
12-1/4” (311mm)
85W PLH
MX1 = Mark X Dimming 26/32/42W, 120V only*
MX2 = Mark X Dimming 26/32/42W, 277V only*
E3 = 347V (Canada)
DA = DALI (Digital Addressable Lighting Interface)**
* 2-wire, neutral connection required
at dimming control
** 5-wire Suspension Kit required
Electrical (continued)
Ballast: Fluorescent: Electronic
26 Watt 32 Watt 42 Watt
Voltage 120 277 120 277 120 277 Total Input Watts 26 26 36 36 47 47 Max. Line Current (Amps) .22 .09 .30 .09 .39 .17
57 Watt 70 Watt 85 Watt
Voltage 120 277 120 277 120 277 Total Input Watts 58 57 73 72 98 98 Max. Line Current (Amps) .52 .21 .61 .27 .82 .36
Power Factor >.98, Ballast Factor .98, THD <10% Minimum Starting Temperature 0°F
Labels
cULus listed suitable for damp locations.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Electrical
Lampholders – Compact Fluorescent:
4-pin, 26/32 watt base: GX24q-3; 42 watt base: GX24q-4; 57 watt base: GX24Q-5; 70 watt base: GX24q-6; 85 watt base: 2G8
Lightolier is a Philips group brand
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • E0708
Specification Decorative Performance Pendalyte 412U
50°
60°
70°
80°
90°
45°
60°
75°
90°
105°
120°
135°
150°
165°
45°
60°
75°
90°
Page 2 of 6 12" Compact Fluorescent
Satin Aluminum Reflector Catalog No. 412U3 / 42SR, 32W CFL, 2400 Lumens.
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method - Effective Floor Reflectance = 20%
Luminaire Input Watts = 33.0
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method - Effective Floor Reflectance = 20%
Luminaire Input Watts = 32.0
500
60°
1000
1500
30°
Report No. 2666FR SC = .7
White Glass Reflector
250
60°
500
750
30°
Report No. 2650FR SC = .9
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS
0 2023
5 2015 188 10 1841 15 1554 440 20 1256 25 995 459 30 724 35 427 279 40 199 45 76 75 50 38 55 22 21
60 13
65 8 9 70 5 75 2 2 80 0 85 0 0 90 0
Catalog No. 412U3 / 42WH, 32W CFL, 2400 Lumens.
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS ANGLE MEAN CP LMS 0 864 90 75 5 867 81 95 79 87 10 813 100 84 15 724 205 105 88 93 20 637 110 91 25 544 248 115 94 93 30 420 120 97 35 272 178 125 98 87 40 174 130 98 45 135 108 135 98 75 50 115 140 97 55 103 93 145 95 59 60 95 150 92 65 89 88 155 86 40 70 84 160 77 75 80 85 165 66 18 80 77 170 49 85 74 82 175 29 3 90 75 180 20
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 1087 45.31 73.81 0-40 1366 56.93 92.74 0-60 1462 60.95 99.27 0-90 1473 61.39 100.00 40-90 107 4.46 7.26 60-90 10 .45 .73 90-180 0 .00 .00 0-180 1473 61.39 100.00
** EFFICIENCY = 61.4% **
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 534 22.29 31.00 0-40 713 29.73 41.34 0-60 914 38.12 53.02 0-90 1169 48.74 67.78 40-90 456 19.01 26.44 60-90 254 10.62 14.76 90-180 556 23.17 32.22 0-180 1725 71.91 100.00
** EFFICIENCY=71.9% **
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .73 .73 .73 .73 .71 .71 .68 .68 .65 .65 .61 1 .70 .69 .68 .66 .68 .65 .65 .63 .63 .62 .59 2 .68 .65 .63 .61 .64 .61 .62 .59 .60 .58 .56 3 .65 .62 .59 .57 .61 .57 .60 .56 .58 .55 .54 4 .63 .59 .56 .54 .58 .54 .57 .53 .56 .53 .51 5 .60 .56 .53 .51 .55 .51 .54 .50 .53 .50 .48 6 .58 .53 .50 .48 .53 .48 .52 .48 .51 .47 .46 7 .55 .51 .48 .46 .50 .45 .49 .45 .49 .45 .44 8 .53 .48 .45 .43 .48 .43 .47 .43 .47 .43 .42 9 .51 .46 .43 .41 .46 .41 .45 .40 .45 .40 .39 10 .49 .44 .41 .39 .44 .39 .43 .39 .43 .38 .38
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .80 .80 .80 .80 .76 .76 .67 .67 .59 .59 .49 1 .73 .70 .67 .65 .66 .61 .59 .55 .52 .49 .41 2 .67 .62 .58 .54 .59 .52 .53 .47 .47 .43 .36 3 .63 .56 .51 .47 .53 .45 .48 .42 .43 .38 .32 4 .58 .51 .46 .42 .49 .40 .44 .38 .40 .35 .30 5 .55 .47 .41 .37 .45 .36 .41 .34 .37 .31 .27 6 .51 .43 .38 .34 .41 .33 .38 .31 .34 .29 .25 7 .48 .40 .34 .31 .38 .30 .35 .28 .32 ..26 23 8 .45 .37 .32 .28 .35 .27 .33 .26 .30 .24 .21 9 .42 .34 .29 .26 .33 .25 .30 .24 .28 .23 .20 10 .40 .32 .27 .24 .31 .23 .28 .22 .26 .21 .19
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Amber Glass Reflector
225
450
675
900
30°
Catalog No. 412U3 / 42AB, 32W CFL, 2400 Lumens.
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS ANGLE MEAN CP LMS 0 885 90 3 5 895 84 95 3 3 10 840 100 3 15 750 213 105 4 4 20 662 110 4
60°
25 567 259 115 5 5 30 438 120 5 35 282 85 125 5 5 40 179 130 5 45 132 106 135 5 4 50 104 140 5 55 82 75 145 5 3 60 65 150 4 65 51 51 155 3 1 70 39 160 2 75 27 29 165 1 0 80 18 170 1 85 9 11 175 0 0 90 3 180 0
Report No. 2647FR SC = .9
Lightolier is a Philips group brand
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 555 23.13 53.49 0-40 740 30.85 71.34 0-60 921 38.38 88.76 0-90 1012 42.18 97.53 40-90 271 11.32 26.18 60-90 91 3.79 8.77 90-180 25 1.07 2.47 0-180 1037 43.25 100.00
** EFFICIENCY = 43.2% **
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • E0708
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
0 .51 .51 .51 .51 .50 .50 .47 .47 .45 .43 4.2 1 .48 .47 .46 .45 .46 .44 .44 .42 .42 .41 .39 2 .46 .43 .41 .40 .42 .39 .41 .38 .39 .37 .35 3 .43 .40 .38 .36 .39 .35 .38 .35 .37 .34 .32 4 .41 .37 .35 .33 .37 .32 .35 .32 .34 .31 .30 5 .38 .35 .32 .30 .34 .30 .33 .29 .32 .29 .28 6 .36 .32 .29 .28 .32 .27 .31 .27 .30 .27 .26 7 .34 .30 .27 .25 .30 .25 .29 .25 .28 .25 .24 8 .33 .28 .25 .24 .28 .23 .27 .23 .27 .23 .22 9 .31 .26 .24 .22 .26 .22 .26 .22 .25 .21 .21 10 .29 .25 .22 .20 .25 .20 .24 .20 .24 .20 .19
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 32.0
Notes: Amber Glass and Cobalt Blue Glass have the same Photometrics.
Specification Decorative Performance Pendalyte 412U
37.5°
40°
42.5°
45°
47.5°
50°
52.5°
55°
57.5°
60°
62.5°
65°
67.5°
70°
72.5°
75°
77.5°
80°
82.5°
85°
87.5°
90°
45°
60°
75°
90°
105°
120°
135°
150°
165°
180°
45°
60°
75°
90°
Page 3 of 6 12" Compact Fluorescent
Satin Aluminum Reflector Catalog No. 412U3 / 42SR, 42W CFL, 3200 Lumens.
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method - Effective Floor Reflectance = 20%
Luminaire Input Watts = 59.0
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method - Effective Floor Reflectance = 20%
Luminaire Input Watts = 39.0
500
60°
1000
1500
2000
30°
Report No. 2665FR SC = .8
White Glass Reflector
250
60°
500
750
30°
Report No. 2649FR SC = .9
CANDLEPOWER SUMMARY
ANGLE MEANCP LMS 0 2184 5 2175 204 10 1997 15 1723 488 20 1445 25 1214 564 30 1005 35 737 456 40 425 45 194 172 50 73 55 37 38
60 21
65 11 12
70 6
75 2 2 80 0 85 0 0 90 0
Catalog No. 412U3 / 42WH, 42W CFL, 3200 Lumens.
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS ANGLE MEAN CP LMS 0 920 90 97 5 917 86 95 102 112 10 863 100 108 15 778 221 105 113 119 20 696 110 117 25 607 278 115 120 119 30 495 120 123 35 359 227 125 124 111 40 236 130 125 45 180 145 135 124 96 50 150 140 123 55 134 121 145 120 75 60 123 150 116 65 114 114 155 109 50 70 108 160 99 75 103 109 165 85 24 80 100 170 64 85 96 106 175 39 4 90 97 180 27
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 1255 39.25 64.86 0-40 1711 53.50 88.42 0-60 1921 60.05 99.24 0-90 1936 60.51 100.00 40-90 224 7.01 11.58 60-90 14 .46 .76 90-180 0 .00 .00 0-180 1936 60.51 100.00
** EFFICIENCY = 60.5% **
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 585 18.29 27.64 0-40 812 25.40 38.38 0-60 1078 33.71 50.93 0-90 1407 43.99 66.47 40-90 594 18.59 28.09 60-90 329 10.29 15.54 90-180 710 22.19 33.53 0-180 2117 66.18 100.00
** EFFICIENCY=66.2% **
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .72 .72 .72 .72 .70 .70 .67 .67 .64 64 .61 1 .69 .68 .66 .65 .66 .64 .64 .62 .62 .60 .57 2 .66 .64 .61 .60 .62 .59 .60 .58 .59 .56 .54 3 .63 .60 .57 .55 .59 .55 .58 .54 .56 .53 .51 4 .60 .56 .54 .51 .56 .51 .55 .50 .53 .50 .48 5 .58 .53 .50 .48 .53 .47 .52 .47 .51 .47 .45 6 .55 .50 .47 .45 .50 .45 .49 .44 .48 .44 .43 7 .52 .47 .44 .42 .47 .42 .46 .41 .45 .41 .40 8 .50 .45 .41 .39 .44 .39 .44 .39 .43 .39 .38 9 .47 .42 .39 .36 .42 .36 .1 .36 .41 .36 .35 10 .45 .40 .36 .34 .39 .34 .39 .34 .38 .34 .33
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .74 .74 .74 .74 .69 .69 .61 .61 .54 .54 .44 1 .67 .64 .61 .59 .60 .55 .53 .50 .47 .44 .37 2 .62 .57 .53 .49 .54 .47 .48 .43 .42 .38 .32 3 .57 .51 .46 .42 .48 .41 .43 .37 .39 .34 .28 4 .53 46 .41 .37 .44 .36 .40 .33 .35 .30 .26 5 .49 .42 .37 .33 .40 .32 .36 .30 .33 .27 .23 6 .46 .38 .33 .30 .37 .29 .33 .27 .30 .25 .21 7 .43 .35 .30 .27 .34 .26 .31 .24 .28 .23 .20 8 .40 .33 .28 .24 .31 .24 .28 .22 .26 .21 .18 9 .38 .30 .25 .22 .29 .22 .26 .20 .24 .19 .17 10 .36 .28 .23 .20 .27 .20 .25 .19 .23 .18 .15
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Amber Glass Reflector
Catalog No. 412U3 / 42AB, 42W CFL, 3200 Lumens.
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS ANGLE MEAN CP LMS 0 983 90 4
250
500
750
1000
5 988 93 95 4 4 10 931 100 4 15 842 239 105 5 5 20 753 110 6
60°
25 657 301 115 6 6 30 533 120 7 35 385 244 125 7 6 40 249 130 7 45 181 145 135 6 5 50 137 140 5 55 109 99 145 5 3 60 85 150 5 65 66 67 155 4 2 70 51 160 3 75 36 38 165 2 1 80 23 170 1 85 12 14 175 0 0
30°
90 4 180 0
Report No. 2648FR SC = .9
Lightolier is a Philips group brand
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 632 19.76 49.78 0-40 876 27.38 68.97 0-60 1119 34.99 88.13 0-90 1238 38.70 97.47 40-90 362 11.32 28.50 60-90 118 3.71 9.33 90-180 32 1.01 2.53 0-180 1270 39.70 100.00
** EFFICIENCY = 39.7% **
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • E0708
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
0 .47 .47 .47 .47 .46 .46 .44 .44 .41 .41 .39 1 .44 .43 .42 .41 .42 .40 .40 .39 .38 .37 .35 2 .42 .39 .38 .36 .39 .35 .37 .35 .36 .34 .32 3 .39 .36 .34 .32 .36 .32 .34 .31 .33 .31 .29 4 .37 .34 .31 .29 .33 .29 .32 .29 .31 .28 .27 5 .35 .31 .28 .27 .31 .26 .30 .26 .29 .26 .25 6 .33 .29 .26 .24 .29 .24 .28 .24 .27 .24 .23 7 .31 .27 .24 .22 .26 .22 .26 .22 .25 .22 .21 8 .29 .25 .22 .21 .25 .20 .24 .20 .24 .20 .19 9 .28 .23 .21 .19 .23 .19 .23 .19 .22 .19 .18 10 .26 .22 .19 .18 .22 .18 .21 .17 .21 .17 .17
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 39.0
Notes: Amber Glass and Cobalt Blue Glass have the same Photometrics.
Specification Decorative Performance Pendalyte 412U
60°
75°
90°
45°
60°
75°
90°
105°
120°
135°
150°
165°
45°
60°
75°
90°
Page 4 of 6 12" Compact Fluorescent
Satin Aluminum Reflector Catalog No. 41257U / 42SR, 57W CFL, 4300 Lumens.
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method - Effective Floor Reflectance = 20%
Luminaire Input Watts = 59.0
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method - Effective Floor Reflectance = 20%
Luminaire Input Watts = 54.0
625
60°
1250
1875
2500
30°
Report No. 2592FR SC = .7
White Glass Reflector
250
500
750
1000
Report No. 2645FR SC = .9
60°
30°
CANDLEPOWER SUMMARY
ANGLE MEANCP LMS 0 2414 5 2354 220
10 2076
15 1746 498 20 1459 25 1261 588 30 1104 35 928 579 40 730 45 534 412 50 328 55 156 157 60 58 65 26 31
70 12
75 4 5 80 0 85 0 0 90 0
Catalog No. 41257U / 42WH, 57W CFL, 4300 Lumens.
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS ANGLE MEAN CP LMS 0 1139 90 140 5 1129 106 95 148 162 10 1037 100 156 15 930 264 105 163 172 20 832 110 168 25 744 343 115 172 170 30 639 120 175 35 511 323 125 176 157 40 394 130 175 45 302 241 135 173 133 50 244 140 169 55 208 189 145 164 103 60 184 150 157 65 170 170 155 147 68 70 159 160 133 75 151 160 165 114 32 80 145 170 87 85 139 154 175 55 6 90 140 180 42
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 1305 30.37 52.46 0-40 1885 43.84 75.73 0-60 2453 57.05 98.55 0-90 2489 57.89 100.00 40-90 604 14.05 24.27 60-90 36 .84 1.45 90-180 0 .00 .00 0-180 2489 57.89 100.00
** EFFICIENCY = 57.9% **
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 712 16.57 24.15 0-40 1035 24.08 35.09 0-60 1465 34.08 49.65 0-90 1949 45.33 66.04 40-90 913 21.25 30.95 60-90 483 11.25 16.39 90-180 1002 23.31 33.96 0-180 2951 68.64 100.00
** EFFICIENCY=68.6% **
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .69 .69 .69 .69 .67 .67 .64 .64 .62 .62 .58 1 .66 .64 .63 .61 .63 .60 .60 .58 .58 .57 .54 2 .62 .60 .57 .55 .59 .55 .57 .53 .55 .52 .50 3 .59 .55 .52 .50 .54 .50 .53 .49 .52 .48 .47 4 .56 .52 .48 .46 .51 .46 .50 .45 .49 .45 .43 5 .53 .48 .44 .42 .47 .42 .46 .41 .45 .41 .40 6 .50 .45 .41 .39 .44 .38 .43 .38 .42 .38 .37 7 .47 .41 .38 .35 .41 .35 .40 .35 .39 .35 .34 8 .44 .38 .35 .32 .38 .32 .37 .32 .37 .32 .31 9 .42 .36 .32 .30 .35 .30 .35 .29 .34 .29 .28 10 .39 .33 .30 .27 .33 .27 .32 .27 .32 .27 .26
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .76 .76 .76 .76 .72 .72 .63 .63 .56 .56 .45 1 .69 .66 .63 .60 .62 .57 .55 .51 .48 .45 .37 2 .63 .58 .54 .50 .55 .48 .49 .43 .43 .39 .32 3 .58 .52 .47 .43 .49 .41 .44 .37 .39 .34 .28 4 .54 .47 .42 .38 .45 .36 .40 .33 .36 .30 .25 5 .50 .42 .37 .33 .40 .32 .36 .29 .33 .27 .23 6 .47 .39 .33 .29 .37 .28 .33 .26 .30 .24 .21 7 .43 .35 .30 .26 .34 .25 .30 .24 .27 .22 .19 8 .41 .32 .27 .24 .31 .23 .28 .21 .26 .20 .17 9 .38 .30 .25 .21 .28 .21 .26 .19 .24 .18 .15 10 .36 .27 .23 .19 .26 .19 .24 .18 .22 .16 .14
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Amber Glass Reflector
325
650
975
1300
30°
Catalog No. 41257U / 42AB, 57W CFL, 4300 Lumens.
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS ANGLE MEAN CP LMS 0 1279 90 5 5 1263 118 95 5 6 10 1155 100 6 15 1040 295 105 7 7 20 932 110 7
60°
25 835 384 115 8 8 30 713 120 8 35 565 356 125 9 8 40 427 130 9 45 312 249 135 8 7 50 233 140 8 55 176 161 145 8 5 60 134 150 7 65 103 104 155 5 2 70 77 160 4 75 55 59 165 2 1 80 35 170 1 85 18 21 175 0 0 90 5 180 0
Report No. 2646FR SC = .9
Lightolier is a Philips group brand
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 797 18.54 44.54 0-40 1153 26.83 64.45 0-60 1563 36.37 87.36 0-90 1747 40.63 97.61 40-90 593 13.80 33.16 60-90 183 4.27 10.25 90-180 42 .99 2.39 0-180 1789 41.63 100.00
** EFFICIENCY = 41.6% **
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • E0708
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
0 .49 .49 .49 .49 .48 .48 .46 .46 .44 .44 .41 1 .46 .45 .44 .42 .44 .42 .42 .40 .40 .39 .37 2 .43 .41 .39 .37 .40 .37 .38 .36 .37 .35 .33 3 .41 .37 .35 .33 .37 .33 .35 .32 .34 .31 .30 4 .38 .34 .32 .30 .34 .29 .33 .29 .32 .28 .27 5 .36 .32 .29 .27 .31 .26 .30 .26 .29 .26 .25 6 .34 .29 .26 .24 .29 .24 .28 .24 .27 .24 .23 7 .31 .27 .24 .22 .27 .22 .26 .22 .25 .21 .21 8 .30 .25 .22 .20 .25 .20 .24 ..20 .24 .20 .19 9 .28 .23 .20 .18 .23 .18 .22 .18 .22 .18 .17 10 .26 .22 .19 .17 .21 .17 .21 .17 .20 .17 .16
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 54.0
Notes: Amber Glass and Cobalt Blue Glass have the same Photometrics.
Specification Decorative Performance Pendalyte 412U
60°
90°
50°
60°
70°
80°
90°
100°
110°
120°
130°
140°
150°
160°
170°
45°
60°
75°
90°
Page 5 of 6 12" Compact Fluorescent
Satin Aluminum Reflector Catalog No. 41270U / 42SR, 70W CFL, 5200 Lumens.
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method - Effective Floor Reflectance = 20%
Luminaire Input Watts = 79.0
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method - Effective Floor Reflectance = 20%
Luminaire Input Watts = 72.0
625
60°
1250
1875
2500
30°
Report No. 2606FR SC = .8
White Glass Reflector
500
1000
1500
Report No. 2644FR SC = 1.0
60°
30°
CANDLEPOWER SUMMARY
ANGLE MEANCP LMS 0 2545 5 2483 232 10 2218 15 1906 544 20 1654 25 1494 696 30 1375 35 1229 768 40 1056 45 880 679 50 694 55 497 446
60 301
65 131 151 70 44 75 14 19 80 0 85 0 0 90 0
Catalog No. 41270U / 42WH, 70W CFL, 5200 Lumens.
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS ANGLE MEAN CP LMS 0 1401 90 220 5 1384 130 95 231 252 10 1283 100 242 15 1172 334 105 252 266 20 1084 110 259 25 1013 465 115 265 262 30 913 120 267 35 781 491 125 268 240 40 649 130 266 45 541 421 135 262 203 50 443 140 256 55 365 334 145 247 155 60 318 150 237 65 284 284 155 221 102
70 260 160 200
75 244 259 165 173 48 80 232 170 133 85 219 243 175 86 9 90 220 180 67
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 1473 28.33 41.65 0-40 2240 43.09 63.36 0-60 3366 64.74 95.19 0-90 3536 68.01 100.00 40-90 1295 24.92 36.64 60-90 170 3.27 4.81 90-180 0 .00 .00 0-180 3536 68.01 100.00
** EFFICIENCY = 68.0% **
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 929 17.88 20.67 0-40 1420 27.31 31.58 0-60 2175 41.84 48.37 0-90 2961 56.95 65.84 40-90 1541 29.64 34.26 60-90 785 15.11 17.47 90-180 1536 29.55 34.16 0-180 4497 86.49 100.00
** EFFICIENCY=86.5% **
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .81 .81 .81 .81 .79 .79 .76 .76 .72 .72 .68 1 .76 .74 .72 .71 .73 .69 .70 .67 .67 .65 .62 2 .72 .68 .65 .62 .67 .62 .65 .60 .63 .59 .57 3 .67 .62 .58 .55 .61 .55 .60 .54 .58 .53 .51 4 .63 .57 .53 .49 .56 .49 .55 .49 .53 .48 .46 5 .59 .52 .48 .44 .52 .44 .50 .44 .49 .43 .42 6 .55 .48 .43 .40 .47 .40 .46 .39 .45 .39 .38 7 .51 .44 .39 .36 .43 .35 .42 .35 .41 .35 .33 8 .48 .40 .35 .32 .40 .32 .39 .32 .38 .31 .30 9 .45 .37 .32 .29 .37 .29 .36 .29 .35 .28 .27 10 .42 .34 .29 .26 .34 .26 .33 .26 .32 .26 .25
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .96 .96 .96 .96 .90 .90 .80 .80 .70 .70 .57 1 .87 .83 .79 .75 .78 .71 .69 .64 .60 .57 .46 2 .79 .73 .67 .62 .68 .59 .61 .53 .53 .48 .39 3 .73 .64 .58 .53 .61 .50 .54 .46 .48 .41 .34 4 .67 .58 .51 .46 .55 .44 .49 .40 .43 .36 .30 5 .62 .52 .45 .40 .49 .38 .44 .35 .39 .32 .27 6 .58 .47 .40 .35 .45 .34 .40 .31 .36 .28 .24 7 .53 .42 .36 .31 .40 .30 .36 .27 .33 .25 .21 8 .50 .39 .32 .27 .37 .26 .33 .25 .30 .23 .19 9 .46 .36 .29 .24 .34 .24 .31 .22 .28 .20 .17 10 .43 .33 .26 .22 .31 .21 .28 .20 .26 .18 .15
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Amber Glass Reflector
375
750
1025
1500
Lightolier is a Philips group brand
Report No. 2643FR SC = 1.0
30°
Catalog No. 41270U / 42AB, 70W CFL, 5200 Lumens.
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS ANGLE MEAN CP LMS 0 1444 90 7 5 1450 136 95 6 7 10 1351 100 7 15 1233 351 105 8 8 20 1139 110 8
60°
25 1057 486 115 8 8 30 944 120 8 35 794 499 125 8 7 40 643 130 8 45 512 398 135 8 6 50 392 140 8 55 286 265 145 7 4 60 219 150 6 65 163 165 155 5 2 70 119 160 4 75 83 90 165 3 1 80 53 170 2 85 27 31 175 0 0 90 7 180 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 972 18.71 39.46 0-40 1471 28.30 59.70 0-60 2135 41.07 86.62 0-90 2421 46.56 98.21 40-90 949 18.26 38.51 60-90 285 5.49 11.59 90-180 44 .85 1.79 0-180 2465 47.41 100.00
** EFFICIENCY = 47.4% **
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • E0708
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
0 .56 .56 .56 .56 .55 .55 .52 .52 .50 .50 .47 1 .53 .51 .49 .48 .50 .47 .48 .45 .46 .44 .41 2 .49 .46 .44 .41 .45 .41 .43 .40 .42 .39 .37 3 .46 .42 .39 .36 .41 .36 .40 .35 .38 .35 .33 4 .43 .38 .35 .32 .38 .32 .36 .32 .35 .31 .30 5 .40 .35 .31 .29 .34 .29 .33 .28 .32 .28 .27 6 .37 .32 .28 .26 .32 .26 .21 .26 .30 .25 .24 7 .35 .29 .26 .23 .29 .23 .28 .23 .27 .23 .22 8 .32 .27 .23 .21 .26 .21 .26 .21 .25 .21 .20 9 .30 .25 .21 .19 .24 .19 .24 .19 .23 .19 .18 10 .28 .23 .19 .17 .23 .17 .22 .17 .22 .17 .16
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 72.0
Notes: Amber Glass and Cobalt Blue Glass have the same Photometrics.
Specification Decorative Performance Pendalyte 412U
30°
40°
50°
60°
70°
80°
90°
40°
50°
60°
70°
80°
90°
100°
110°
120°
130°
140°
150°
160°
170°
45°
60°
75°
90°
Page 6 of 6 12" Compact Fluorescent
Satin Aluminum Reflector Catalog No. 41285U / 42SR, 85W CFL, 6000 Lumens.
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method - Effective Floor Reflectance = 20%
Luminaire Input Watts = 96.0
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method - Effective Floor Reflectance = 20%
Luminaire Input Watts = 72.0
500
60°
1000
1500
30°
Report No. 2577FR SC = 1.2
White Glass Reflector
200
400
600
800
1000
Report No. 2642FR SC = 1.3
60°
30°
CANDLEPOWER SUMMARY
ANGLE MEANCP LMS
0 1611
5 1632 155 10 1628 15 1564 443 20 1492 25 1428 658 30 1338 35 1195 746 40 1023 45 852 660 50 679 55 491 441 60 305 65 138 156 70 46 75 14 20 80 0 85 0 0 90 0
Catalog No. 41285U / 42WH, 85W CFL, 6000 Lumens.
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS ANGLE MEAN CP LMS 0 949 90 198 5 960 91 95 209 228 10 957 100 219 15 932 265 105 227 240 20 913 110 234 25 892 408 115 239 236 30 825 120 241 35 718 451 125 242 216 40 609 130 240 45 510 398 135 235 182 50 425 140 228 55 338 311 145 216 135 60 288 150 201 65 257 257 155 183 84 70 235 160 161 75 220 234 165 132 37 80 210 170 100 85 199 220 175 66 7 90 198 180 56
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 1255 20.93 38.31 0-40 2002 33.37 61.07 0-60 3102 51.71 94.64 0-90 3278 54.64 100.00 40-90 1276 21.27 38.93 60-90 175 2.93 5.36 90-180 0 .00 .00 0-180 3278 54.64 100.00
** EFFICIENCY = 54.6% **
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 763 12.73 19.09 0-40 1214 20.24 30.35 0-60 1923 32.06 48.08 0-90 2634 43.92 65.87 40-90 1420 23.68 35.52 60-90 711 11.86 17.78 90-180 1365 22.76 34.13 0-180 4000 66.67 100.00
** EFFICIENCY=66.7% **
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .65 .65 .65 .65 .64 .64 .61 .61 .58 .58 .55 1 .61 .60 .58 .56 .58 .56 .56. 54 .54 .52 .50 2 .58 .54 .52 .50 .53 .49 .52 .48 .50 .47 .45 3 .54 .49 .46 .44 .49 .43 .47 .43 .46 .42 .40 4 .50 .45 .42 .39 .45 .39 .43 .38 .42 .38 .36 5 .47 .41 .37 .34 .41 .34 .40 .34 .39 .34 .32 6 .44 .38 .34 .31 .37 .31 .36 .30 .35 .30 .29 7 .40 .34 .30 .27 .34 .27 .33 .27 .32 .27 .26 8 .38 .31 .27 .24 .31 .24 .30 .24 .29 .24 .23 9 .35 .28 .24 .22 .28 .22 .27 .21 .27 .21 .20 10 .32 .26 .22 .19 .26 .19 .25 .19 .25 .19 .18
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .74 .74 .74 .74 .70 .70 .61 .61 .54 .54 .44 1 .67 .63 .61 .58 .60 .55 .53 .49 .46 .43 .35 2 .61 .56 .51 .48 .52 .45 .46 .41 .41 .37 .30 3 .56 .49 .44 .40 .46 .38 .41 .35 .37 .31 .26 4 .52 .44 .39 .35 .42 .33 .37 .30 .33 .28 .23 5 .48 .39 .34 .30 .37 .29 .34 .26 .30 .24 .20 6 .44 .36 .30 .26 .34 .25 .30 .23 .27 .21 .18 7 .40 .32 .27 .23 .31 .22 .27 .20 .25 .19 .15 8 .38 .29 .24 .20 .28 .20 .25 .18 .23 .17 .14 9 .35 .27 .21 .18 .25 .17 .23 .16 .21 .15 .12 10 .33 .24 .19 .16 .23 .16 .21 .14 .19 .13 .11
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Amber Glass Reflector
Catalog No. 41285U / 42AB, 85W CFL, 6000 Lumens.
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS ANGLE MEAN CP LMS 0 1033 90 7
250
500
750
1000
Report No. 2641FR SC = 1.2
Lightolier is a Philips group brand
5 1042 99 95 6 7
10 1036 100 7
15 1004 285 105 7 8 20 978 110 7
60°
25 947 433 115 8 8 30 866 120 8 35 743 466 125 8 7 40 615 130 8 45 495 385 135 8 6 50 384 140 7 55 275 255 145 7 4 60 203 150 6 65 151 153 155 5 2
70 110 160 3
75 78 83 165 3 1 80 50 170 1 85 26 30 175 0 0
30°
90 7 180 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 816 13.61 36.59 0-40 1282 21.38 57.48 0-60 1922 32.05 86.16 0-90 2188 36.48 98.07 40-90 905 15.10 40.60 60-90 265 4.43 11.91 90-180 43 .72 1.93 0-180 2231 37.19 100.00
** EFFICIENCY = 37.2% **
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • E0708
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
0 .44 .44 .44 .44 .43 .43 .41 .41 .39 .39 .36 1 .41 .40 .39 .37 .39 .37 .37 .35 .36 .34 .32 2 .38 .36 .34 .32 .35 .32 .34 .31 .33 .30 .29 3 .36 .32 .30 .28 .32 .28 .31 .27 .30 .27 .26 4 .33 .30 .27 .25 .29 .25 .28 .24 .27 .24 .23 5 .31 .27 .24 .22 .27 .22 .26 .22 .25 .21 .20 6 .29 .25 .22 .20 .24 .20 .23 .19 .23 .19 .18 7 .27 .22 .19 .18 .22 .17 .21 .17 .21 .17 .16 8 .25 .20 .18 .16 .20 .16 .20 .16 .19 .15 .15 9 .23 .19 .16 .14 .18 .14 .18 .14 .18 .14 .13 10 .22 .17 .14 .13 .17 .13 .17 .13 .16 .12 .12
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 91.0
Notes: Amber Glass and Cobalt Blue Glass have the same Photometrics.