Decorative Performance Pendalyte 406
1
2
3
6 7/8" (175)
Reflector
7 1/8" (181)
Glass Diffuser
5 1/2" (140)
96"
(2438)
11 1/4"
(286)
150W, A-21
26, 32W,
Triple Tube
Compact
Fluorescent
Canopy
Glass
Diffuser
Reflector
Incandescent
Canopy
7 1/4" (184)
2 1/2" (51)
3/4" (19)
Page 1 of 3 6.5” Compact Fluorescent/Incandescent
8292WE
0400
( ) Denotes dimensions in mm
Ordering Information
Power Head and Suspension: Titanium Finish
Catalog No. Lamp Watts Volts Suspension
406U2 CFLTriple Tube 26/32 120/277 Straight Cord
406151 Incandescent A21 150 120 Straight Cord
Reflector/Glass
Catalog No. Description
416SR Satin Aluminum Reflector
416WH White Glass
416BL Cobalt Blue Glass
416AB Amber Glass
Features
1. Reflector System:
Reflector: High purity, 16 gauge aluminum. Exterior satined and anodized.
Interior low iridescent comfort clear anodized.
Glass Diffusers: Pressed colored glass with soft etched exterior and matte
white interior fritt.
2. Power Head Housing: One-piece extruded aluminum.
3. Suspension: Power Cord, SJT/18-3 (incandescent), SJT/18-5 (Compact
Fluorescent) black finish. Canopy, 20 gage, .036 CRS, titanium finish. Can be
field shortened.
Lamping (by others)
Incandescant: 150W, A-21
Compact Fluorescent: Universal for 4-Pin, 26/32 watt, base: GX24q-3
General Electric Osram/Sylvainia Philips
(1) 26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F26TBX/*/A/4P CF26DT/E/IN/* PL-T26W/*/4P
(1) 32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F32TBX/*/A/4P CF32DT/E/IN/* PL-T32W/*/4P
* Manufacturers' color temperature designation.
Electrical
Lampholders:
Incandescent: Medium Based, Porcelain, Nickel-Plated Screw Shell
Compact Fluorescent: 4-pin, 26/32 watt base: GX24Q-3
Ballast: Fluorescent: Electronic
26 Watt 32 Watt
Voltage 120 277 120 277
Total Input Watts 28 28 36 36
Max. Line Current (Amps) .25 .11 .30 .09
Ballast Factor 1.02 1.02 1.00 1.00
THD<10%, Minimum Starting Temperature: 0°F
Power Factor >0.98
Labels
cULus listed suitable for damp locations.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Group LLC • C0605
Decorative Performance Pendalyte 406
Page 2 of 3 6.5” Compact Fluorescent/Incandescent
Satin Aluminum Reflector Catalog No. 406U2 / 416SR, 32W CFL, 2400 Lumens.
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 500 20.84 38.92
0-40 806 33.58 62.72
0-60 1231 51.32 95.84
0-90 1285 53.55 100.00
40-90 479 19.96 37.28
60-90 53 2.23 4.16
90-180 0 .00 .00
0-180 1285 53.55 100.00
** EFFICIENCY = 53.5% **
150
300
450
600
Report No. 2597FR
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS
0 576
5 587 56
10 605
15 612 172
20 605
60°
25 594 271
30 553
35 489 306
40 416
45 342 264
50 263
55 181 162
60 98
65 37 46
70 14
75 6 7
80 1
30°
85 0 0
90 0
SC = 1.3
White Glass Reflector Catalog No. 406U2 / 416WH, 32W CFL, 2400 Lumens.
100
200
300
Report No. 2636FR
SC = 1.1
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS ANGLE MEAN CP LMS
0 349 90 100
5 349 33 95 105 114
10 347 100 109
15 336 95 105 113 119
20 320 110 116
25 295 135 115 118 117
30 260 120 120
35 219 138 125 120 107
60°
30°
40 178 130 119
45 142 112 135 118 91
50 118 140 116
55 106 96 145 112 70
60 98 150 108
65 95 95 155 103 47
70 94 160 93
75 95 101 165 74 20
80 96 170 46
85 95 105 175 20 2
90 100 180 9
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 263 10.98 16.47
0-40 401 16.71 25.06
0-60 609 25.39 38.08
0-90 910 37.94 56.90
40-90 509 21.23 31.83
60-90 301 12.55 18.81
90-180 689 28.74 43.10
0-180 1600 66.68 100.00
** EFFICIENCY = 66.7% **
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method - Effective Floor Reflectance = 20%
0 .64 .64 .64 .64 .62 .62 .59 .59 .57 .57 .54
1 .60 .58 .57 .56 .57 .55 .55 .53 .53 .51 .49
2 .57 .54 .51 .49 .53 .48 .51 .47 .49 .46 .44
3 .53 .49 .46 .43 .48 .43 .47 .42 .45 .41 .40
4 .50 .45 .41 .39 .44 .38 .43 .38 .42 .37 .36
5 .46 .41 .37 .34 .40 .34 .39 .34 .38 .33 .32
6 .43 .37 .33 .31 .37 .30 .36 .30 .35 .30 .29
7 .40 .34 .30 .27 .33 .27 .33 .27 .32 .26 .25
8 .37 .31 .27 .24 .30 .24 .30 .24 .29 .24 .23
9 .34 .28 .24 .21 .28 .21 .27 .21 .27 .21 .20
10 .32 .26 .22 .19 .25 .19 .25 .19 .24 .19 .18
Luminaire Imput Watts = 33.0
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method - Effective Floor Reflectance = 20%
0 .73 .73 .73 .73 .68 .68 .58 .58 .50 .50 .38
1 .65 .62 .58 .56 .57 .52 .49 .45 .42 .49 .29
2 .59 .54 .49 .45 .50 .46 .43 .37 .37 .32 .24
3 .54 .47 .42 .38 .44 .36 .38 .32 .32 .27 .21
4 .50 .42 .37 .33 .40 .31 .34 .27 .29 .24 .18
5 .46 .38 .32 .28 .35 .27 .31 .24 .27 .21 .16
6 .42 .34 .29 .25 .32 .23 .28 .21 .24 .19 .14
7 .39 .31 .25 .22 .29 .21 .25 .19 .22 .16 .13
8 .36 .28 .23 .19 .26 .18 .23 .17 .20 .15 .12
9 .34 .26 .21 .17 .24 .16 .21 .15 .19 .13 .10
10 .32 .24 .19 .15 .22 .15 .20 .13 .17 .12 .09
Luminaire Imput Watts = 31.0
Amber Glass Reflector Catalog No. 406U2 / 416AB, 32W CFL, 2400 Lumens.
100
200
300
400
Report No. 2635FR
SC = 1.1
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS ANGLE MEAN CP LMS
0 396 90 7
5 395 38 95 7 8
10 395 100 8
15 381 108 105 8 9
20 363 110 9
60°
25 334 153 115 9 9
30 293 120 9
35 242 152 125 9 8
40 189 130 9
45 141 111 135 9 7
50 104 140 8
55 80 73 145 8 5
60 61 150 7
65 47 48 155 7 3
70 36 160 6
75 27 29 165 5 1
80 19 170 3
85 12 14 175 1 0
30°
90 7 180 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 298 12.44 38.54
0-40 450 18.76 58.14
0-60 634 26.44 81.94
0-90 724 30.19 93.56
40-90 274 11.43 35.42
60-90 90 3.75 11.63
90-180 49 2.08 6.44
0-180 774 32.27 100.00
** EFFICIENCY = 32.3% **
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Group LLC • C0605
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
Zonal Cavity Method - Effective Floor Reflectance = 20%
RCR
0 .38 .38 .38 .38 .37 .37 .35 .35 .33 .33 .30
1 .35 .34 .33 .32 .33 .31 .32 .30 .30 .29 .27
2 .33 .31 .29 .28 .30 .27 .29 .26 .28 .26 .24
3 .31 .28 .26 .24 .27 .24 .26 .23 .25 .23 .21
4 .29 .26 .24 .22 .25 .22 .24 .21 .23 .21 .19
5 .27 .24 .21 .19 .23 .19 .22 .19 .21 .18 .18
6 .25 .22 .19 .18 .21 .17 .20 .17 .20 .17 .16
7 .23 .20 .17 .16 .19 .16 .19 .15 .18 .15 .14
8 .22 .18 .16 .14 .18 .14 .17 .14 .17 .14 .13
9 .20 .17 .14 .13 .16 .13 .16 .13 .15 .12 .12
10 .19 .15 .13 .12 .15 .12 .15 .11 .14 .11 .11
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Luminaire Imput Watts = 31.0
Notes: Amber Glass and Cobalt Blue Glass
have the same Photometrics.
For 26W Lamp, multiply calculated
Footcandle values by .75