Decorative Performance Pendalyte 406
1
2
3
6 7/8" (175)
Reflector
7 1/8" (181)
Glass Diffuser
5 1/2" (140)
96"
(2438)
11 1/4"
(286)
150W, A-21
26, 32W,
Triple Tube
Compact
Fluorescent
Canopy
Glass
Diffuser
Reflector
Incandescent
Canopy
7 1/4" (184)
2 1/2" (51)
3/4" (19)
Page 1 of 3 6.5” Compact Fluorescent/Incandescent
8292WE
0400
( ) Denotes dimensions in mm
Ordering Information
Power Head and Suspension: Titanium Finish
Catalog No. Lamp Watts Volts Suspension
406U2 CFLTriple Tube 26/32 120/277 Straight Cord
406151 Incandescent A21 150 120 Straight Cord
Reflector/Glass
Catalog No. Description
416SR Satin Aluminum Reflector
416WH White Glass
416BL Cobalt Blue Glass
416AB Amber Glass
Features
1. Reflector System:
Reflector: High purity, 16 gauge aluminum. Exterior satined and anodized.
Interior low iridescent comfort clear anodized.
Glass Diffusers: Pressed colored glass with soft etched exterior and matte
white interior fritt.
2. Power Head Housing: One-piece extruded aluminum.
3. Suspension: Power Cord, SJT/18-3 (incandescent), SJT/18-5 (Compact
Fluorescent) black finish. Canopy, 20 gage, .036 CRS, titanium finish. Can be
field shortened.
Lamping (by others)
Incandescant: 150W, A-21
Compact Fluorescent: Universal for 4-Pin, 26/32 watt, base: GX24q-3
General Electric Osram/Sylvainia Philips
(1) 26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F26TBX/*/A/4P CF26DT/E/IN/* PL-T26W/*/4P
(1) 32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F32TBX/*/A/4P CF32DT/E/IN/* PL-T32W/*/4P
* Manufacturers' color temperature designation.
Electrical
Lampholders:
Incandescent: Medium Based, Porcelain, Nickel-Plated Screw Shell
Compact Fluorescent: 4-pin, 26/32 watt base: GX24Q-3
Ballast: Fluorescent: Electronic
26 Watt 32 Watt
Voltage 120 277 120 277
Total Input Watts 28 28 36 36
Max. Line Current (Amps) .25 .11 .30 .09
Ballast Factor 1.02 1.02 1.00 1.00
THD<10%, Minimum Starting Temperature: 0°F
Power Factor >0.98
Labels
cULus listed suitable for damp locations.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Group LLC • C0605

Decorative Performance Pendalyte 406
Page 2 of 3 6.5” Compact Fluorescent/Incandescent
Satin Aluminum Reflector Catalog No. 406U2 / 416SR, 32W CFL, 2400 Lumens.
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 500 20.84 38.92
0-40 806 33.58 62.72
0-60 1231 51.32 95.84
0-90 1285 53.55 100.00
40-90 479 19.96 37.28
60-90 53 2.23 4.16
90-180 0 .00 .00
0-180 1285 53.55 100.00
** EFFICIENCY = 53.5% **
150
300
450
600
Report No. 2597FR
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS
0 576
5 587 56
10 605
15 612 172
20 605
60°
25 594 271
30 553
35 489 306
40 416
45 342 264
50 263
55 181 162
60 98
65 37 46
70 14
75 6 7
80 1
30°
85 0 0
90 0
SC = 1.3
White Glass Reflector Catalog No. 406U2 / 416WH, 32W CFL, 2400 Lumens.
100
200
300
Report No. 2636FR
SC = 1.1
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS ANGLE MEAN CP LMS
0 349 90 100
5 349 33 95 105 114
10 347 100 109
15 336 95 105 113 119
20 320 110 116
25 295 135 115 118 117
30 260 120 120
35 219 138 125 120 107
60°
30°
40 178 130 119
45 142 112 135 118 91
50 118 140 116
55 106 96 145 112 70
60 98 150 108
65 95 95 155 103 47
70 94 160 93
75 95 101 165 74 20
80 96 170 46
85 95 105 175 20 2
90 100 180 9
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 263 10.98 16.47
0-40 401 16.71 25.06
0-60 609 25.39 38.08
0-90 910 37.94 56.90
40-90 509 21.23 31.83
60-90 301 12.55 18.81
90-180 689 28.74 43.10
0-180 1600 66.68 100.00
** EFFICIENCY = 66.7% **
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method - Effective Floor Reflectance = 20%
0 .64 .64 .64 .64 .62 .62 .59 .59 .57 .57 .54
1 .60 .58 .57 .56 .57 .55 .55 .53 .53 .51 .49
2 .57 .54 .51 .49 .53 .48 .51 .47 .49 .46 .44
3 .53 .49 .46 .43 .48 .43 .47 .42 .45 .41 .40
4 .50 .45 .41 .39 .44 .38 .43 .38 .42 .37 .36
5 .46 .41 .37 .34 .40 .34 .39 .34 .38 .33 .32
6 .43 .37 .33 .31 .37 .30 .36 .30 .35 .30 .29
7 .40 .34 .30 .27 .33 .27 .33 .27 .32 .26 .25
8 .37 .31 .27 .24 .30 .24 .30 .24 .29 .24 .23
9 .34 .28 .24 .21 .28 .21 .27 .21 .27 .21 .20
10 .32 .26 .22 .19 .25 .19 .25 .19 .24 .19 .18
Luminaire Imput Watts = 33.0
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method - Effective Floor Reflectance = 20%
0 .73 .73 .73 .73 .68 .68 .58 .58 .50 .50 .38
1 .65 .62 .58 .56 .57 .52 .49 .45 .42 .49 .29
2 .59 .54 .49 .45 .50 .46 .43 .37 .37 .32 .24
3 .54 .47 .42 .38 .44 .36 .38 .32 .32 .27 .21
4 .50 .42 .37 .33 .40 .31 .34 .27 .29 .24 .18
5 .46 .38 .32 .28 .35 .27 .31 .24 .27 .21 .16
6 .42 .34 .29 .25 .32 .23 .28 .21 .24 .19 .14
7 .39 .31 .25 .22 .29 .21 .25 .19 .22 .16 .13
8 .36 .28 .23 .19 .26 .18 .23 .17 .20 .15 .12
9 .34 .26 .21 .17 .24 .16 .21 .15 .19 .13 .10
10 .32 .24 .19 .15 .22 .15 .20 .13 .17 .12 .09
Luminaire Imput Watts = 31.0
Amber Glass Reflector Catalog No. 406U2 / 416AB, 32W CFL, 2400 Lumens.
100
200
300
400
Report No. 2635FR
SC = 1.1
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS ANGLE MEAN CP LMS
0 396 90 7
5 395 38 95 7 8
10 395 100 8
15 381 108 105 8 9
20 363 110 9
60°
25 334 153 115 9 9
30 293 120 9
35 242 152 125 9 8
40 189 130 9
45 141 111 135 9 7
50 104 140 8
55 80 73 145 8 5
60 61 150 7
65 47 48 155 7 3
70 36 160 6
75 27 29 165 5 1
80 19 170 3
85 12 14 175 1 0
30°
90 7 180 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 298 12.44 38.54
0-40 450 18.76 58.14
0-60 634 26.44 81.94
0-90 724 30.19 93.56
40-90 274 11.43 35.42
60-90 90 3.75 11.63
90-180 49 2.08 6.44
0-180 774 32.27 100.00
** EFFICIENCY = 32.3% **
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Group LLC • C0605
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
Zonal Cavity Method - Effective Floor Reflectance = 20%
RCR
0 .38 .38 .38 .38 .37 .37 .35 .35 .33 .33 .30
1 .35 .34 .33 .32 .33 .31 .32 .30 .30 .29 .27
2 .33 .31 .29 .28 .30 .27 .29 .26 .28 .26 .24
3 .31 .28 .26 .24 .27 .24 .26 .23 .25 .23 .21
4 .29 .26 .24 .22 .25 .22 .24 .21 .23 .21 .19
5 .27 .24 .21 .19 .23 .19 .22 .19 .21 .18 .18
6 .25 .22 .19 .18 .21 .17 .20 .17 .20 .17 .16
7 .23 .20 .17 .16 .19 .16 .19 .15 .18 .15 .14
8 .22 .18 .16 .14 .18 .14 .17 .14 .17 .14 .13
9 .20 .17 .14 .13 .16 .13 .16 .13 .15 .12 .12
10 .19 .15 .13 .12 .15 .12 .15 .11 .14 .11 .11
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Luminaire Imput Watts = 31.0
Notes: Amber Glass and Cobalt Blue Glass
have the same Photometrics.
For 26W Lamp, multiply calculated
Footcandle values by .75

Decorative Performance Pendalyte 406
Page 3 of 3 6.5” Compact Fluorescent/Incandescent
Satin Aluminum Reflector Catalog No. 406151 / 416SR, 150W A-20, 2780 Lumens.
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 616 22.18 34.70
0-40 1081 38.89 60.85
0-60 1716 61.75 96.61
0-90 1776 63.92 100.00
40-90 695 25.02 39.15
60-90 60 2.17 3.39
90-180 0 .00 .00
0-180 1776 63.92 100.00
** EFFICIENCY = 63.9% **
200
400
600
800
Report No. 2594FR
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS
0 628
5 634 61
10 650
15 676 194
60°
20 734
25 796 362
30 801
35 750 465
40 659
45 543 416
50 403
55 237 220
60 101
65 39 49
70 19
75 9 10
30°
80 3
85 0 1
90 0
SC = 1.5
White Glass Reflector Catalog No. 406151 / 416WH, 150W A-21, 2780 Lumens.
100
200
300
400
500
Report No. 2640FR
SC = 1.0
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS ANGLE MEAN CP LMS
0 555 90 125
5 550 52 95 133 144
10 540 100 139
15 527 148 105 145 153
20 501 110 149
25 451 205 115 153 151
30 368 120 155
35 278 177 125 156 140
40 204 130 156
60°
45 159 127 135 155 120
50 135 140 154
55 122 111 145 150 94
60 117 150 146
65 115 115 155 140 64
70 116 160 129
75 118 125 165 104 28
30°
80 120 170 56
85 119 132 175 14 2
90 125 180 2
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 405 14.59 19.42
0-40 582 20.96 27.90
0-60 821 29.53 39.31
0-90 1192 42.89 57.09
40-90 609 21.93 29.18
60-90 371 13.36 17.78
90-180 896 32.24 42.91
0-180 2088 75.13 100.00
** EFFICIENCY = 75.1% **
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method - Effective Floor Reflectance = 20%
0 .76 .76. .76 .76 .74 .74 .71 .71 .68 .68 .64
1 .72 .70 .68 .66 .68 .65 .66 .63 .63 .61 .58
2 .67 .64 .61 .58 .63 .57 .60 .56 .59 .55 .53
3 .63 .58 .54 .51 .57 .51 .55 .50 .54 .49 .47
4 .59 .53 .49 .45 .52 .45 .51 .44 .49 .44 .42
5 .55 .48 .43 .40 .47 .40 .46 .39 .45 .39 .38
6 .51 .44 .39 .35 .43 .35 .42 .35 .41 .35 .33
7 .47 .39 .34 .31 .39 .31 .38 .31 .37 .30 .29
8 .43 .35 .31 .27 .35 .27 .34 .27 .33 .27 .26
9 .40 .32 .27 .24 .32 .24 .31 .24 .30 .24 .22
10 .37 .29 .24 .21 .29 .21 .28 .21 .27 .21 .20
Luminaire Imput Watts = 150.0
COEFFICIENTS OF UTILIZATION
Zonal Cavity Method - Effective Floor Reflectance = 20%
0 .82 .82 .82 .82 .76 .76 .66 .66 .56 .56 .43
1 .74 .70 .66 .63 .65 .59 .56 .52 .47 .44 .34
2 .67 .61 .56 .52 .57 .49 .49 .43 .42 .37 .28
3 .61 .54 .48 .44 .50 .41 .44 .37 .38 .32 .25
4 .57 .49 .43 .38 .46 .36 .40 .32 .34 .28 .22
5 .53 .44 .38 .33 .41 .32 .36 .28 .31 .25 .20
6 .49 .40 .34 .29 .37 .28 .33 .25 .29 .23 .18
7 .45 .36 .30 .26 .34 .25 .30 .23 .26 .20 .16
8 .42 .33 .27 .23 .31 .22 .28 .20 .24 .18 .15
9 .39 .30 .25 .21 .29 .20 .25 .18 .22 .17 .13
10 .37 .28 .23 .19 .26 .18 .24 .17 .21 .15 .12
Luminaire Imput Watts = 150.0
Amber Glass Reflector Catalog No. 406151 / 416AB, 150W A-21, 2780 Lumens.
100
200
300
400
500
600
Report No. 2639FR
SC = 1.0
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS ANGLE MEAN CP LMS
0 638 90 9
5 632 60 95 10 10
10 617 100 10
15 604 170 105 11 12
20 572 110 11
60°
25 516 235 115 12 12
30 423 120 12
35 318 202 125 12 11
40 228 130 12
45 165 132 135 12 9
50 123 140 11
55 94 87 145 11 7
60 74 150 10
65 59 59 155 10 4
70 45 160 9
30°
75 34 36 165 7 2
80 24 170 3
85 15 17 175 0 0
90 9 180 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 464 16.71 43.65
0-40 666 23.97 62.63
0-60 885 31.84 83.18
0-90 997 35.88 93.74
40-90 331 11.91 31.11
60-90 112 4.04 10.57
90-180 66 2.39 6.26
0-180 1064 38.27 100.00
** EFFICIENCY = 38.3% **
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Group LLC • C0605
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
Zonal Cavity Method - Effective Floor Reflectance = 20%
RCR
0 .45 .45 .45 .45 .44 .44 .41 .41 .39 .39 .36
1 .42 .41 .40 .38 .40 .38 .38 .36 .36 .34 .32
2 .39 .37 .35 .34 .36 .33 .35 .32 .33 .31 .29
3 .37 .34 .32 .30 .33 .29 .32 .29 .31 .28 .26
4 .35 .31 .29 .27 .31 .26 .29 .26 .28 .25 .24
5 .33 .29 .26 .24 .28 .24 .27 .23 .26 .23 .22
6 .31 .27 .24 .22 .26 .22 .25 .21 .24 .21 .20
7 .29 .24 .22 .20 .24 .20 .23 .19 .23 .19 .18
8 .27 .23 .20 .18 .22 .18 .22 .18 .21 .18 .17
9 .25 .21 .18 .17 .21 .17 .20 .16 .20 .16 .15
10 .24 .20 .17 .15 .19 .15 .19 .15 .18 .15 .14
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Luminaire Imput Watts = 150.0
Notes: Amber Glass and Cobalt Blue Glass
have the same Photometrics.