Specification Decorative Pendalyte
™
404722XU3
Page 1 of 2 12" 2 Lamp Pendant
2
18 1/4"
or
15 3/8"
6 1/4"
8 1/2"
or
5 5/8"
2 1/4"
3
5 1/2"
5 1/2"
1
7 1/2"
12 13/32
† Larger dimensions apply to Dimming Fixtures.
Complete fixture consists of Reflector, Power Head and Suspension. Select each separately.
2x26W Triple Tube
2x32W Triple Tube
2x42W Triple Tube
4
Suspension Details
3/4"
Cable/Coiled Cord
3/4"
Cable/Cord
5 1/2"
10 3/8"
7/8"
SWIVEL JOINT (35˚)
5/8" STEEL TUBING
Stem
Close to Ceiling Kit
3/4"
U, U3 = Standard Ballast
UE3, U3E3 = Standard Ballast
(347V)
U2MX1 = Mark X Dimming
26W, 120V*
U2MX2 = Mark X Dimming
26W, 277V*
U4MX1 = Mark X Dimming
32/42W, 120V*
U4MX2 = Mark X Dimming
32/42W, 277V*
* 2-Wire, Neutral Conn ection required at
Dimming Cont rol
Reflector/Refractor Power Head
Cat. No. Cat. No. Lamp Watts Volts Options - suf fix to be added to Cat.No. (i.e.404722XU3)
40421 Anodized Reflector Semi Specular 40472 2X CFL Triple Tube 2x26/32/42 120/277 U3, U3E3, U2MX1,U2MX2, U4MX1, U4MX2
4042 2 Acrylic Refractor
Reflector/Refractor Options Suspension Optional Extension Kits
Cat. No Description Use With Cat No. Color Description Cat No. Color Description
421G
422A
404TRM12
412GRL
412WHL
422G
®
Industrex
Flat Acrylic Lens
12" Trim Ring
Cross Blade Louver Gray
Cross Blade Louver White
Industrex Glass Lens
Glass Lens
40421
40422
40422/40421
40421
40421
40422
404SKG
404S36
404S60
404S120
404GL S
4912CTCGR
Gray
Cable/Straight Cord 120" Length
Gray
36" Length, 5/8" Stem
Gray
60" Length, 5/8" Stem
Gray
120" Length, 5/8" Stem
Gray
Track Mounting Kit
Gray
Direct to Ceiling Kit
for Standard 12" Pendalytes
404EXT300*
Gray 25' Ext. Cable Cord Kit
* Use along with
standard suspen-
sion kit.
Features
1. Refractor/Reflector: Injection Molded Acr ylic, UV Stabilized or Semi-specular
High Purity Anodized Aluminum, 16 gauge iridescence-free.
2. Power Head Housing: Two-piece extruded aluminum. Removable door
allows for ease of installation and servicing. Dark Gray textured powder
coat finish.
3. Suspension: Cable/Cord: 1/16" Stainless Steel/SJT 18-3, Gray.
Cable/Coiled Cord: 1/16" Stainless Steel/SJT 18-3, Gray. Gray Canopy.
Stem: 5/8" Steel tubing and canopy, with 35 degree swivel hanger. Gray Finish.
4. Shielding Options: Clear Acrylic Lens, Industrex® Glass Lens or Louver.
Deco Kit Available (see spec sheet 412DK)
Lamping (by others)
Compact Fluorescent:
General Electric
|
(2) 26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F26TBX/*/A/4P
|
(2) 32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F32TBX/*/A/4P
|
(2) 42W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F42TBX/*/A/4P
|
*Manufacturers’ color temperature designation.
Osram/Sylvania
|
CF26DT/E/IN/*
|
CF32DT/E/IN/*
|
CF42DT/E/IN/*
|
Philips
|
PL-T26W/*/4P
|
PL-T32W/*/4P
|
PL-T42W/*/4P
|
Electrical
Lampholders:
Compact Fluorescent: 4-Pin, 26/32 watt base: GX24q-3;
42 watt base: GX24q-4
Electrical (continued)
Ballasts: Fluorescent: Electronic
2x26 Watt 2x32 Watt 2x42 Watt
Voltage 120 277 120 277 120 277
Total Input Watts -55 -55 -68 -68 -93 -93
Max. Line Current (Amps) .46 .21 .57 .25 .78 .33
Power Factor > 0.98, Ballast Factor 0.98, THD < 10%, Minimum Starting
Temperature 0°F.
Labels
cULus listed suitable for damp locations.
Industrex® is a registered trademark of AFG Industries, Inc.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • I0109
Lightolier is a Philips group brand
Specification Decorative Pendalyte
™
404722XU3
Page 2 of 2 12" 2 Lamp Pendant
Application Data
Multiple Units (2x26W Triple Tube ) with cross blade louver
Spacing Height Initial Watts
on to Lighted Foot- Per
Center Plane candles Sq. Ft.
12’ 68
12’ 38
12’ 24
Based on 60" x 60" room with 80% ceiling cavity, 50% wall and 20% floor reflectances.
Height is from bottom of fixture to lighted plane.
6’ 75
6’
6’ 42
8’
6’ 27
10’
1.50
0.86
0.55
Application Data
Multiple Units (2x32W Triple Tube, CFL)
Spacing Height Initial Watts
on to Lighted Foot- Per
Center Plane candles Sq. Ft.
12’ 53
12’ 30
12’ 19
Based on 60" x 60" room with 80% ceiling cavity, 50% wall and 20% floor reflectances.
Height is from bottom of fixture to lighted plane.
6’ 62
6’
6’ 35
8’
6’ 22
10’
1.00
0.56
0.36
Illuminance (FC) Multipliers For Compact Fluorescent:
32 Watt = 1.3
42 Watt = 1.8
Spacing Ratio = 1.5 2x26W Triple Tube CFL
CERTIFIED TEST REPORT NO. 0807FR COMPUTED BY LSI PROGRAM **TEST-LITE**
LIGHTOLIER DUAL COMPACT FLUORESCENT PENDANT FIXTURE CAT. #4047233/404L12
12 1/2" DIA. CLEAR ANODIZED REFLECTOR WITH WHITE CROSS BLADE
2-26W PLT TRIPLE TUBE PHILIPS LAMPS. LUMEN RATING = 1800 LMS.
ESI BALLAST CAT.#ESI 2/1-CFQ-26UNV, 120 VAC
0 813
5 898 86
10 976
15 936 266
20 907
25 905 416
30 874
35 831 522
40 789
45 722 552
50 620
55 479 423
60 308
65 156 177
70 95
75 66 70
80 39
85 15 20
90 1
0-30 767 21.31 30.30
0-40 1289 35.82 50.92
0-60 2265 62.91 89.44
0-90 2532 70.34 100.00
40-90 1242 34.52 49.08
60-90 267 7.43 10.56
90-180 0 .00 .00
0-180 2532 70.34 100.00
** EFFICIENCY = 70.3% **
Coefficients Of Utilization 2-26W Triple Tube CFL
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
80 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .75 .73 .71 .74 .72 .70 .71 .69 .68 .68 .67 .65 .66 .65 .64 .62
2 .68 .64 .61 .67 .63 .60 .64 .61 .59 .62 .60 .57 .60 .58 .56 .55
3 .61 .56 .52 .60 .55 .52 .58 .54 .51 .56 .53 .50 .54 .52 .49 .48
4 .55 .50 .46 .54 .49 .45 .52 .48 .45 .51 .47 .44 .49 .46 .44 .42
5 .50 .44 .40 .49 .43 .40 .47 .43 .39 .46 .42 .39 .45 .41 .38 .37
6 .44 .39 .35 .44 .38 .35 .43 .38 .34 .41 .37 .34 .40 .37 .34 .32
7 .40 .34 .30 .39 .34 .30 .38 .33 .30 .37 .33 .29 .36 .32 .29 .28
ROOM CAVITY RATIO
8 .36 .30 .26 .35 .30 .26 .35 .30 .26 .34 .29 .26 .33 .29 .26 .25
9 .33 .27 .23 .32 .27 .23 .31 .26 .23 .31 .26 .23 .30 .26 .23 .21
10 .29 .24 .38 .29 .24 .20 .28 .24 .20 .28 .23 .20 .27 .23 .20 .19
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
Illuminance (FC) Multipliers For Compact Fluorescent:
26 Watt = 0.7
42 Watt = 1.3
Spacing Ratio = 3.3 2x32W Triple Tube CFL
LIGHTOLIER DUAL COMPACT FLUORESCENT PENDANT FIXTURE CAT. #4047233/40422
Coefficients Of Utilization 2x32W Triple Tube CFL
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50 30 10 0
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .73 .70 .67 .70 .67 .63 .63 .60 .58 .56 55 .53 .51 .49 .48 .45
2 .64 .58 .54 .60 .56 .51 .55 .51 .47 .49 .46 .43 .44 .42 .40 .37
3 .55 .49 .44 .53 .47 .42 .48 .43 .39 .43 .39 .36 .39 .36 .33 .30
4 .49 .42 .37 .47 .41 .36 .42 .37 .33 .38 .34 .31 .34 .31 .28 .26
5 .43 .36 .31 .41 .35 .30 .37 .32 .28 .34 .29 .26 .30 .27 .24 .22
6 .38 .31 .26 .36 .30 .25 .33 .27 .23 .30 .25 .22 .27 .23 20 .18
7 . 33 .27 .22 .32 .26 .21 .29 .23 .20 .26 .21 .18 .23 .20 .17 .15
ROOM CAVITY RATIO
8 .30 .23 .19 .28 .22 .18 .26 .20 .17 .23 .19 .15 .21 .17 .14 .12
9 27 .20 .16 .25 .19 .15 .23 .18 .14 .21 .16 .13 .19 .15 .12 .10
10 .24 .18 .32 .23 .17 .13 .21 .16 .12 .19 .14 .11 .17 .13 .10 .09
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • I0109
12 1/2" DIA. REFRACTOR WITH PLASTIC LENS
2-32W PLT TRIPLE TUBE PHILIPS LAMPS. LUMEN RATING = 2400 LMS
MOTOROLA BALLAST CAT.M2CF26/32/42
0 297
5 324 32
10 387
15 469 133
20 541
25 605 280
30 667
35 725 451
40 752
45 726 553
50 650
55 547 490
60 440
65 343 342
70 250
75 187 217
80 196
85 201 218
90 198
0-30 443 9.25 12.10
0-40 894 18.63 24.39
0-60 1936 40.35 52.80
0-90 2712 56.51 73.96
40-90 1818 37.88 49.58
60-90 776 16.17 21.16
90-180 954 19.89 26.04
0-180 3667 76.41 100.00
** EFFICIENCY = 76.4% **
% WALL REFLECTION
20% FLOOR CAVITY REFLECTANCE
95 210 226
100 209
105 208 221
110 210
115 204 201
120 189
125 170 153
130 148
135 122 95
140 95
145 67 43
150 42
155 26 14
160 19
165 17 5
170 15
175 12 2
180 11
Lightolier is a Philips group brand