READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
INSTRUCTION SHEET NO.
IS:28702
1299 Page 1 of 2
INSTRUCTIONS FOR ATTACHING ProSpec®ADAPTER TO ProSpec®TRACK
For use with ProSpec
®
Track Systems Only
LIGHTOLIER a GENLYTE company.
631 Airport Road, Fall River, MA 02720
®
1. Select the CIRCUIT in ProSpec TRACK you want the ProSpec SPOT to be powered with (Fig.1) by orienting the LEVER towards the side of the TRACK of the selected CIRCUIT. (Fig. 2)
2. With the CLAMPING TABS in the down position, insert ADAPTER into ProSpec TRACK and flip the CLAMPING TABS up to secure the ADAPTER. (Fig. 3)
3. To energize FIXTURE, turn LEVER all the way until LEVER is parallel to ProSpec TRACK. (Fig. 4)
4. To remove FIXTURE, reverse procedure in Step 3 then flip down CLAMPING TABS and pull FIXTURE out of ProSpec TRACK.
DO NOT ATTEMPT TO RELEASE CLAMPING TABS before disconnecting power with LEVER.
NEVER PLACE FINGERS ABOVE THE BARRIERS ON THE CLAMPING TABS WHEN INSTALLING OR REMOVING FIXTURE.
5. To change FIXTURE to second circuit, remove FIXTURE as indicated in Step 4, then turn FIXTURE around 180° until LEVER is pointing to the other side of ProSpec TRACK and installed as indicated in Step 2.
INSTRUCTIONS FOR ATTACHING ADAPTER TO ProSpec
®
TWO CIRCUIT TRACK
CIRCUIT 1
Fig. 1
Fig. 4
CIRCUIT 2
CIRCUIT 1 CIRCUIT 2
Fig. 2
Fig. 3
LEVER
CLAMPING TABS
ProSpec TRACK
ADAPTER
TRACK
BARRIER
BARRIER
FINGER LOCATION FOR REMOVAL
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
INSTRUCTION SHEET NO.
IS:28702
1299 Page 2 of 2
LIGHTOLIER a GENLYTE THOMAS company.
631 Airport Road, Fall River, MA 02720
®
INSTRUCTIONS FOR OPERATING A L0W-VOLTAGE METALLICS
TM
FIXTURE
WARNING: RISK OF FIRE. FIXTURES 8702 & 28702, WHEN USED WITH AN OPTISPOT SHADE, GENERATE INTENSE LIGHT BEAM. COMBUSTIBLE MATERIALS MUST BE SPACED AT LEAST 4 FT. AWAY WHEN USING THE 8710 AND 2 FT. AWAY WHEN USING THE 8730 (SEE FIG. 5). ALWAYS USE CARE WHEN ILLUMINATING HEAT SENSITIVE OBJECTS.
NOTE: For dimming, use only dimmers approved for use with
low voltage lamps and electronic transformers.
AIMING ADJUSTMENTS
CAUTION: ALLOW TIME FOR FIXTURE TO COOL BEFORE MAKING ANY ADJUSTMENTS!
Rotate fixture to the desired position using the HOLE located in the back of the ARM as a handle. Fixture has horizontal and vertical rotation stops (DO NOT FORCE FIXTURE PAST STOPS. DOING SO WILL CAUSE AN ELECTRICAL HAZARD). See Figs. 6 & 7.
HORIZONTAL ROTATION
ARM
HOLE
FIXTURE 28702 WITH
OPTISPOT SHADE (sold separately)
VERTICAL ROTATION
OPTISPOT SHADE
Fixture 28702 with Optispot shade
(sold separately)
Fig. 6
Fig. 5 Applies only when using the 8710, 8730 OptiSpot Shades
Fig. 7
FOR T4 LAMPING INFORMATION, SEE LIGHTOLIER INSTRUCTION SHEET 8710. FOR MR16 LAMPING INFORMATION, SEE LIGHTOLIER INSTRUCTION SHEET 8727M16.
Fixture 28702 with MR16 Dome shade
(sold separately)
CAUTION: NEVER ENERGIZE OR OPERATE FIXTURE 28702 WITHOUT AN OPTISPOT OR MR16 DOME SHADE ATTACHED. LAMP MUST BE COVERED AT ALL TIMES.